The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Identical, but not the same: Intra-site and inter-site reproducibility of fractional anisotropy measures on two 3.0T scanners
Open accessAbstract
Diffusion Tensor Imaging (DTI) is being increasingly used to assess white matter integrity and it is therefore paramount to address the test-retest reliability of DTI measures. In this study we assessed inter- and intra-site reproducibility of two nominally identical 3T scanners at different sites in nine healthy controls using a DTI protocol representative of typical current "best practice" including cardiac gating, a multichannel head coil, parallel imaging and optimized diffusion gradient parameters. We calculated coefficients of variation (CV) and intraclass correlation coefficients (ICC) of fractional anisotropy (FA) measures for the whole brain, for three regions of interest (ROI) and for three tracts derived from these ROI by probabilistic tracking. We assessed the impact of affine, nonlinear and template based methods for spatially aligning FA maps on the reproducibility. The intra-site CV for FA ranged from 0.8% to 3.0% with ICC from 0.90 to 0.99, while the inter-site CV ranged from 1.0% to 4.1% with ICC of 0.82 to 0.99. Nonlinear image coregistration improved reproducibility compared to affine coregistration. Normalization to template space reduced the between-subject variation, resulting in lower ICC values and indicating a possibly reduced sensitivity. CV from probabilistic tractography were about 50% higher than for the corresponding seed ROI. Reproducibility maps of the whole scan volume showed a low variation of less than 5% in the major white matter tracts but higher variations of 10-15% in gray matter regions. One of the two scanners showed better intra-site reproducibility, while the intra-site CV for both scanners was significantly better than inter-site CV. However, when using nonlinear coregistration of FA maps, the average inter-site CV was below 2%. There was a consistent inter-site bias, FA values on site 2 were 1.0-1.5% lower than on site 1. Correction for this bias with a global scaling factor reduced the inter-site CV to the range of intra-site CV. Our results are encouraging for multi-centre DTI studies in larger populations, but also illustrate the importance of the image processing pipeline for reproducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Stereotaxic Display of Brain Lesions
Rorden, C., & Brett, M. (2000) · Behavioural Neurology · doi:10.1155/2000/421719 · Cited by 2,590
Diffusion tensor imaging and aging
Sullivan, E. V., & Pfefferbaum, A. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.002 · Cited by 649
Camino: Open-Source Diffusion-MRI Reconstruction and Processing
Cook, P. A., Bai, Y., Nedjati-Gilani, S., Seunarine, K. K., Hall, M. G., Parker, G. J. M., & Alexander, D. C. (2006) · Cited by 453
Landman, B. A., Farrell, J. A. D., Jones, C. K., Smith, S. A., Prince, J. L., & Mori, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.056 · Cited by 285
Focke, N. K., Yogarajah, M., Bonelli, S. B., Bartlett, P. A., Symms, M. R., & Duncan, J. S. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.031 · Cited by 282
Self-citationInvestigating Cervical Spinal Cord Structure Using Axial Diffusion Tensor Imaging
Wheeler-Kingshott, C. A. M., Hickman, S. J., Parker, G. J. M., Ciccarelli, O., Symms, M. R., Miller, D. H., & Barker, G. J. (2002) · NeuroImage · doi:10.1006/nimg.2001.1022 · Cited by 266
Self-citationBonekamp, D., Nagae, L. M., Degaonkar, M., Matson, M., Abdalla, W. M. A., Barker, P. B., Mori, S., & Horská, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.020 · Cited by 260
Heiervang, E., Behrens, T. E. J., Mackay, C. E., Robson, M. D., & Johansen-Berg, H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.037 · Cited by 259
From diffusion tractography to quantitative white matter tract measures: a reproducibility study
Ciccarelli, O., Parker, G. J. M., Toosy, A. T., Wheeler-Kingshott, C. A. M., Barker, G. J., Boulby, P. A., Miller, D. H., & Thompson, A. J. (2003) · NeuroImage · doi:10.1016/s1053-8119(02)00042-3 · Cited by 228 · cited 3×
“The intra-site test–retest reliability of DTI measures has been addressed mainly at 1.5 Tesla (T) (Ciccarelli et al., 2003; Pfefferbaum et al., 2003; Heiervang et al., 2006; Bonekamp et al., 2007) with just two recent studies at 3 T (Jansen et al., 2007; Bisdas et al., 2008) (Table 1).”
InfluentialSelf-citationA Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRI
Papadakis, N. G., Xing, D., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1673 · Cited by 203
Jones, D. K., Williams, S. C. R., Gasston, D., Horsfield, M. A., Simmons, A., & Howard, R. (2002) · Human Brain Mapping · doi:10.1002/hbm.10018 · Cited by 179
Ni, H., Kavcic, V., Zhu, T., EKHOLM, S. E., & Zhong, J. (2006) · PubMed · Cited by 177
Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain
Adolf Pfefferbaum, A., Elfar Adalsteinsson, A., & Sullivan, E. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10377 · Cited by 160
On the effects of gating in diffusion imaging of the brain using single shot EPI
Skare, S. T., & Andersson, J. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00415-5 · Cited by 157
Applications of Diffusion Tensor MR Imaging in Multiple Sclerosis
Ge, Y., Law, M., & Grossman, R. I. (2005) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1340.039 · Cited by 105
Alexander, A. L., Lee, J. E., Wu, Y., & Field, A. S. (2006) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2006.02.006 · Cited by 93
Bisdas, S., Bohning, D. E., Bešenski, N., Nicholas, J. S., & Rumboldt, Z. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1044 · Cited by 83
(2003) · PubMed Central · Cited by 76
Jansen, J. F. A., Kooi, M. E., Kessels, A. G. H., Nicolay, K., & Backes, W. H. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000262757.10271.e5 · Cited by 58
A method for improving the performance of gradient systems for diffusion‐weighted MRI
Nagy, Z., Weiskopf, N., Alexander, D. C., & Deichmann, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21379 · Cited by 40
Cited by
Brain atrophy in Alzheimer’s Disease and aging
Pini, L., Pievani, M., Bocchetta, M., Altomare, D., Bosco, P., Cavedo, E., Galluzzi, S., Marizzoni, M., & Frisoni, G. B. (2016) · Ageing Research Reviews · doi:10.1016/j.arr.2016.01.002 · Cited by 836
Prediction as a Humanitarian and Pragmatic Contribution from Human Cognitive Neuroscience
Gabrieli, J. D. E., Ghosh, S. S., & Whitfield-Gabrieli, S. (2015) · Neuron · doi:10.1016/j.neuron.2014.10.047 · Cited by 535
Effect of long-term cannabis use on axonal fibre connectivity
Zalesky, A., Solowij, N., Yucel, M., Lubman, D. I., Takagi, M., Harding, I. H., Lorenzetti, V., Wang, R., Searle, K., Pantelis, C., et al. (2012) · Brain · doi:10.1093/brain/aws136 · Cited by 326
Figley, C. R., Uddin, M. N., Wong, K., Kornelsen, J., Puig, J., & Figley, T. D. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.799576 · Cited by 253
Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain
Grech‐Sollars, M., Hales, P. W., Miyazaki, K., Raschke, F., Rodriguez, D., Wilson, M., Gill, S. K., Banks, T., Saunders, D. E., Clayden, J. D., et al. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3269 · Cited by 213
Metadata
- Authors
- Vollmar, C., O'Muircheartaigh, J., Barker, G. J., Symms, M. R., Thompson, P., Kumari, V., Duncan, J. S., Richardson, M. P., & Koepp, M. J.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 51
- Issue
- 4
- Pages
- 1384-1394
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W1979893109
- Cited by
- 259
- References
- 23
- FWCI
- 10.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.