The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Improved recovery of the hemodynamic response in diffuse optical imaging using short optode separations and state-space modeling
Open accessAbstract
Diffuse Optical Imaging (DOI) allows the recovery of the hemodynamic response associated with evoked brain activity. The signal is contaminated with systemic physiological interference which occurs in the superficial layers of the head as well as in the brain tissue. The back-reflection geometry of the measurement makes the DOI signal strongly contaminated by systemic interference occurring in the superficial layers. A recent development has been the use of signals from small source-detector separation (1 cm) optodes as regressors. Since those additional measurements are mainly sensitive to superficial layers in adult humans, they help in removing the systemic interference present in longer separation measurements (3 cm). Encouraged by those findings, we developed a dynamic estimation procedure to remove global interference using small optode separations and to estimate simultaneously the hemodynamic response. The algorithm was tested by recovering a simulated synthetic hemodynamic response added over baseline DOI data acquired from 6 human subjects at rest. The performance of the algorithm was quantified by the Pearson R2 coefficient and the mean square error (MSE) between the recovered and the simulated hemodynamic responses. Our dynamic estimator was also compared with a static estimator and the traditional adaptive filtering method. We observed a significant improvement (two-tailed paired t-test, p < 0.05) in both HbO and HbR recovery using our Kalman filter dynamic estimator compared to the traditional adaptive filter, the static estimator and the standard GLM technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Haykin, S. (1986) · Cited by 12,603
Rogers, S. (1996) · Control Engineering Practice · doi:10.1016/0967-0661(96)82838-3 · Cited by 9,278
GELB, A. (1974) · CERN Document Server (European Organization for Nuclear Research) · Cited by 6,405
Kalman Filtering and Neural Networks
(2001) · Wiley eBooks · doi:10.1002/0471221546 · Cited by 2,386
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Maximum likelihood estimates of linear dynamic systems
RAUCH, H. E., TUNG, F., & STRIEBEL, C. T. (1965) · AIAA Journal · doi:10.2514/3.3166 · Cited by 1,943
Deconvolution of Impulse Response in Event-Related BOLD fMRI1
Glover, G. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0419 · Cited by 1,386
Villringer, A., Planck, J., Hock, C., Schleinkofer, L., & Dirnagl, U. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90181-j · Cited by 1,119
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Self-citationBoas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Self-citationSpontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Functional near-infrared spectroscopy: current status and future prospects
Hoshi, Y. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804911 · Cited by 468
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Zhang, Y., Brooks, D. H., Franceschini, M. A., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852552 · Cited by 373
Self-citationWavelet minimum description length detrending for near-infrared spectroscopy
Jang, K. E., Tak, S., Jung, J., Jang, J., Jeong, Y., & Ye, J. C. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3127204 · Cited by 279
Jasdzewski, G., Strangman, G., Wagner, J., Kwong, K. K., Poldrack, R. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00311-2 · Cited by 277
Self-citationFranceschini, M. A., Fantini, S., Thompson, J. H., Culver, J. P., & Boas, D. A. (2003) · Psychophysiology · doi:10.1111/1469-8986.00057 · Cited by 275
Self-citationDirect characterization and removal of interfering absorption trends in two-layer turbid media
Saager, R. B., & Berger, A. J. (2005) · Journal of the Optical Society of America A · doi:10.1364/josaa.22.001874 · Cited by 271
Diffuse optical imaging of the whole head
Franceschini, M. A., Joseph, D. K., Huppert, T. J., Diamond, S. G., & Boas, D. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2363365 · Cited by 242
Self-citationAbdelnour, A. F., & Huppert, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.033 · Cited by 208
Zhang, Q., Strangman, G. E., & Ganis, G. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.048 · Cited by 176
Toronov, V., Franceschini, M. A., Filiaci, M., Fantini, S., Wolf, M., Michalos, A., & Gratton, E. (2000) · Medical Physics · doi:10.1118/1.598943 · Cited by 169
Zhang, Q., Brown, E. N., & Strangman, G. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2754714 · Cited by 163
Gregg (2010) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2010.00014 · Cited by 161
GRATTON, G., & CORBALLIS, P. M. (1995) · Psychophysiology · doi:10.1111/j.1469-8986.1995.tb02958.x · Cited by 160
Saager, R. B., & Berger, A. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2940587 · Cited by 155
Hu, X., Hong, K., Ge, S. S., & Jeong, M.-Y. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-82 · Cited by 143
Zhang, Q., Brown, E. N., & Strangman, G. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804706 · Cited by 132
Multidistance probe arrangement to eliminate artifacts in functional near-infrared spectroscopy
Yamada, T., Umeyama, S., & Matsuda, K. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3275469 · Cited by 126
Dynamic physiological modeling for functional diffuse optical tomography
Diamond, S. G., Huppert, T. J., Kolehmainen, V., Franceschini, M. A., Kaipio, J. P., Arridge, S., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.016 · Cited by 116
Self-citationTime-series estimation of biological factors in optical diffusion tomography
Prince, S. J. D., Kolehmainen, V., Kaipio, J. P., Franceschini, M. A., Boas, D. A., & Arridge, S. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/301 · Cited by 112
Self-citationHuppert, T. J., Allen, M., Benav, H., Jones, P., & Boas, D. A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600435 · Cited by 111
Self-citationHuppert, T. J., Hoge, R. D., Dale, A. M., Franceschini, M. A., & Boas, D. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2400910 · Cited by 87
Self-citationEstimating cerebral oxygen metabolism from fMRI with a dynamic multicompartment Windkessel model
Huppert, T. J., Allen, M., Diamond, S. G., & Boas, D. A. (2008) · Human Brain Mapping · doi:10.1002/hbm.20628 · Cited by 55
Self-citationDirect estimation of evoked hemoglobin changes by multimodality fusion imaging
Huppert, T. J., Diamond, S. G., & Boas, D. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976432 · Cited by 42
Self-citationWavelet-based estimation of the hemodynamic responses in diffuse optical imaging
Lina, J.-M., Matteau-Pelletier, C., Dehaes, M., Desjardins, M., & Lesage, F. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.04.006 · Cited by 25
Diamond, S. G., Perdue, K. L., & Boas, D. A. (2009) · Mathematical Biosciences · doi:10.1016/j.mbs.2009.05.002 · Cited by 25
Self-citation
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Best practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Statistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
Cooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421
Self-citation
Metadata
- Authors
- Gagnon, L., Perdue, K., Greve, D. N., Goldenholz, D., Kaskhedikar, G., & Boas, D. A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2011-06
- Volume
- 56
- Issue
- 3
- Pages
- 1362-1371
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2026337283
- Cited by
- 278
- References
- 41
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.