The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near‐infrared optical imaging
Open accessAbstract
We have performed a noninvasive bilateral optical imaging study of the hemodynamic evoked response to unilateral finger opposition task, finger tactile, and electrical median nerve stimulation in the human sensorimotor cortex. This optical study shows the hemoglobin‐evoked response to voluntary and nonvoluntary stimuli. We performed measurements on 10 healthy volunteers using block paradigms for motor, sensory, and electrical stimulations of the right and left hands separately. We analyzed the spatial/temporal features and the amplitude of the optical signal induced by cerebral activation during these three paradigms. We consistently found an increase (decrease) in the cerebral concentration of oxy‐hemoglobin (deoxy‐hemoglobin) at the cortical side contralateral to the stimulated side. We observed an optical response to activation that was larger in size and amplitude during voluntary motor task compared to the other two stimulations. The ipsilateral response was consistently smaller than the contralateral response, and even reversed (i.e., a decrease in oxy‐hemoglobin, and an increase in deoxy‐hemoglobin) in the case of the electrical stimulation. We observed a systemic contribution to the optical signal from the increase in the heart rate increase during stimulation, and we made a first attempt to subtract it from the evoked hemoglobin signal. Our findings based on optical imaging are in agreement with results in the literature obtained with positron emission tomography and functional magnetic resonance imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Effect of subjective perspective taking during simulation of action: a PET investigation of agency
Ruby, P., & Decety, J. (2001) · Nature Neuroscience · doi:10.1038/87510 · Cited by 1,182
Haxby, J., Horwitz, B., Ungerleider, L., Maisog, J., Pietrini, P., & Grady, C. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-11-06336.1994 · Cited by 1,068
Functional Magnetic Resonance Imaging of Motor Cortex: Hemispheric Asymmetry and Handedness
Kim, S.-G., Ashe, J., Hendrich, K., Ellermann, J. M., Merkle, H., Uğurbil, K., & Georgopoulos, A. P. (1993) · Science · doi:10.1126/science.8342027 · Cited by 983
Patterns of Hand Preference in a Student Population
Briggs, G. G., & Nebes, R. D. (1975) · Cortex · doi:10.1016/s0010-9452(75)80005-0 · Cited by 771
Spatial and temporal analysis of human motor activity using noninvasive NIR topography
Maki, A., Yamashita, Y., Ito, Y., Watanabe, E., Mayanagi, Y., & Koizumi, H. (1995) · Medical Physics · doi:10.1118/1.597496 · Cited by 689
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Self-citation
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationRecent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Self-citationBoas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Self-citation
Metadata
- Authors
- Franceschini, M. A., Fantini, S., Thompson, J. H., Culver, J. P., & Boas, D. A.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2003-06-10
- Volume
- 40
- Issue
- 4
- Pages
- 548-560
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2138418088
- Cited by
- 275
- References
- 72
- FWCI
- 11.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near‐infrared optical imaging. https://app.cochat.ai/papers/10.1111/1469-8986.00057
- The paper
- Franceschini, M. A., Fantini, S., Thompson, J. H., Culver, J. P., & Boas, D. A. (2003). Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near‐infrared optical imaging. Psychophysiology. https://doi.org/10.1111/1469-8986.00057
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.