Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
In this work we investigate the effects of echo planar imaging (EPI) distortions on diffusion tensor imaging (DTI) based fiber tractography results. We propose a simple experimental framework that would enable assessing the effects of EPI distortions on the accuracy and reproducibility of fiber tractography from a pilot study on a few subjects. We compare trajectories computed from two diffusion datasets collected on each subject that are identical except for the orientation of phase encode direction, either right–left (RL) or anterior–posterior (AP). We define metrics to assess potential discrepancies between RL and AP trajectories in association, commissural, and projection pathways. Results from measurements on a 3 Tesla clinical scanner indicated that the effects of EPI distortions on computed fiber trajectories are statistically significant and large in magnitude, potentially leading to erroneous inferences about brain connectivity. The correction of EPI distortion using an image-based registration approach showed a significant improvement in tract consistency and accuracy. Although obtained in the context of a DTI experiment, our findings are generally applicable to all EPI-based diffusion MRI tractography investigations, including high angular resolution (HARDI) methods. On the basis of our findings, we recommend adding an EPI distortion correction step to the diffusion MRI processing pipeline if the output is to be used for fiber tractography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 1×
“For these reasons, to investigate the improvements of EPI distortion correction and the effects of phase encode direction on tract reproducibility, a probabilistic tractography framework was employed using the FSL software package (Smith et al., 2004).”
MethodProbabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471 · cited 2×
“Probabilistic tractography as proposed by Behrens et al. (2007) is a tool for analysis of DTI based " connectivity " that provides information on expected re producibility within a single scan.”
BackgroundMethodTuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
A diffusion tensor imaging tractography atlas for virtual in vivo dissections.
CATANI, M., & THIEBAUTDESCHOTTEN, M. (2008) · Cortex · doi:10.1016/j.cortex.2008.05.004 · Cited by 1,642 · cited 1×
“DTI-based fiber " tractography " (Basser et al., 2000; Mori et al., 1999; Wedeen and Reese, 1997) methods have been used to extract plausible trajectories of major white matter pathways non-invasively (Catani and Schotten, 2008).”
MethodTournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635 · cited 1×
“…to the works of Tuch (2002), Jansons and Alexander (2003), Blyth et al. (2003), Chen et al. (2004), Behrens et al. (2007), Anderson and Ding (2002), Tournier et al. (2004), Özarslan et al. (2006), Parker and Alexander (2005), Descoteaux et al. (2009), Jian and Vemuri (2007), Jeurissen et al.…”
BackgroundDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827 · cited 2×
“…Rohde et al. (2004), which includes proper reor ientation of the B-matrix to account for rotational differences among the diffusion weighted volumes, and an intensity correction based on the Jacobian of the transformations (Jones and Cercignani, 2010; Leemans and Jones, 2009; Rohde et al., 2004).”
BackgroundMethodDeterministic and probabilistic tractography based on complex fibre orientation distributions
Descoteaux, M., Deriche, R., Knosche, T. R., & Anwander, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004424 · Cited by 698 · cited 1×
“…Jansons and Alexander (2003), Blyth et al. (2003), Chen et al. (2004), Behrens et al. (2007), Anderson and Ding (2002), Tournier et al. (2004), Özarslan et al. (2006), Parker and Alexander (2005), Descoteaux et al. (2009), Jian and Vemuri (2007), Jeurissen et al. (2011) and Qazi et al. (2009).”
BackgroundDauguet, J., Peled, S., Berezovskii, V., Delzescaux, T., Warfield, S. K., Born, R., & Westin, C.-F. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.067 · Cited by 233 · cited 1×
“In this work, we employed the Dice metric on the visitation counts direct ly, instead of its typical use on binary segmented images employed in Dauguet et al. (2007) and O'Muircheartaigh et al. (2011).”
Method
Cited by
Smith, R. E., Tournier, J.-D., Calamante, F., & Connelly, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.005 · Cited by 1,216
“Independent of the ACT framework, performing EPI distortion correction has been demonstrated to be beneficial for fibre-tracking consistency and accuracy (Irfanoglu et al., 2012).”
MethodSIFT: Spherical-deconvolution informed filtering of tractograms
Smith, R. E., Tournier, J.-D., Calamante, F., & Connelly, A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.049 · Cited by 752
Thomas, C., Ye, F. Q., Irfanoglu, M. O., Modi, P., Saleem, K. S., Leopold, D. A., & Pierpaoli, C. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405672111 · Cited by 725
Self-citationLimits to anatomical accuracy of diffusion tractography using modern approaches
Schilling, K. G., Nath, V., Hansen, C., Parvathaneni, P., Blaber, J., Gao, Y., Neher, P., Aydogan, D. B., Shi, Y., Ocampo-Pineda, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.029 · Cited by 260
“These artifacts can lead to uncertainty in orientation estimates [4, 5], biases in diffusion indices [6], geometric distortion in pathways [7], all of which can result in anatomically incorrect tractography [8].”
BackgroundSelf-citationBilliet, T., Vandenbulcke, M., Mädler, B., Peeters, R., Dhollander, T., Zhang, H., Deprez, S., Van den Bergh, B. R. H., Sunaert, S., & Emsell, L. (2015) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2015.02.029 · Cited by 203
Metadata
- Authors
- Irfanoglu, M. O., Walker, L., Sarlls, J., Marenco, S., & Pierpaoli, C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2012-05
- Volume
- 61
- Issue
- 1
- Pages
- 275-288
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2119450847
- Cited by
- 215
- References
- 9
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results. https://app.cochat.ai/papers/10.1016/j.neuroimage.2012.02.054
- The paper
- Irfanoglu, M. O., Walker, L., Sarlls, J., Marenco, S., & Pierpaoli, C. (2012). Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results. NeuroImage. https://doi.org/10.1016/j.neuroimage.2012.02.054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.