Inter-site and inter-scanner diffusion MRI data harmonization
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We propose a novel method to harmonize diffusion MRI data acquired from multiple sites and scanners, which is imperative for joint analysis of the data to significantly increase sample size and statistical power of neuroimaging studies. Our method incorporates the following main novelties: i) we take into account the scanner-dependent spatial variability of the diffusion signal in different parts of the brain; ii) our method is independent of compartmental modeling of diffusion (e.g., tensor, and intra/extra cellular compartments) and the acquired signal itself is corrected for scanner related differences; and iii) inter-subject variability as measured by the coefficient of variation is maintained at each site. We represent the signal in a basis of spherical harmonics and compute several rotation invariant spherical harmonic features to estimate a region and tissue specific linear mapping between the signal from different sites (and scanners). We validate our method on diffusion data acquired from seven different sites (including two GE, three Philips, and two Siemens scanners) on a group of age-matched healthy subjects. Since the extracted rotation invariant spherical harmonic features depend on the accuracy of the brain parcellation provided by Freesurfer, we propose a feature based refinement of the original parcellation such that it better characterizes the anatomy and provides robust linear mappings to harmonize the dMRI data. We demonstrate the efficacy of our method by statistically comparing diffusion measures such as fractional anisotropy, mean diffusivity and generalized fractional anisotropy across multiple sites before and after data harmonization. We also show results using tract-based spatial statistics before and after harmonization for independent validation of the proposed methodology. Our experimental results demonstrate that, for nearly identical acquisition protocol across sites, scanner-specific differences can be accurately removed using the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 2×
“It is known from several earlier works [27, 28, 29, 30] that multiple fiber crossings can be detected even at low b-values of 900 to 1000.”
BackgroundHan, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Mueller, S. G., Weiner, M. W., Thal, L. J., Petersen, R. C., Jack, C. R., Jagust, W., Trojanowski, J. Q., Toga, A. W., & Beckett, L. (2005) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2005.06.003 · Cited by 1,233
Regularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
Diffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Jahanshad, N., Kochunov, P. V., Sprooten, E., Mandl, R. C., Nichols, T. E., Almasy, L., Blangero, J., Brouwer, R. M., Curran, J. E., de Zubicaray, G. I., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.061 · Cited by 393
Salimi-Khorshidi, G., Smith, S. M., Keltner, J. R., Wager, T. D., & Nichols, T. E. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.039 · Cited by 388
Orthogonal tensor invariants and the analysis of diffusion tensor magnetic resonance images
Ennis, D. B., & Kindlmann, G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20741 · Cited by 276 · cited 2×
“Note that in our pipeline, RISH features are used as the basis although there are other tensor-based RI features [32, 33] such as the eigenvalues, MD, FA, and other fourth-order tensor invariants [34].”
MethodFox, R. J., Sakaie, K., Lee, J.-C., Debbins, J. P., Liu, Y., Arnold, D. L., Melhem, E. R., Smith, C. H., Philips, M. D., Lowe, M., et al. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2844 · Cited by 137 · cited 2×
“BMC Med Imaging (2011) 11–23 [13] Foxa, R.”
Background
Cited by
Harmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580
“For diffusion tensor imaging (DTI) studies, it has been proposed to use spherical harmonics to harmonize data across studies, using a reference site to create pairwise site transformations (Mirzaalian et al., 2016).”
MethodHarmonization of multi-site diffusion tensor imaging data
Fortin, J.-P., Parker, D., Tunç, B., Watanabe, T., Elliott, M. A., Ruparel, K., Roalf, D. R., Satterthwaite, T. D., Gur, R. C., Gur, R. E., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.047 · Cited by 1,261
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Novikov, D. S., Veraart, J., Jelescu, I. O., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.006 · Cited by 237
“, 2003) for using such approach for image matching in computer vision, (Mirzaalian et al., 2016) for dMRI data harmonization, and (Reisert et al.”
MethodDeep learning-based unlearning of dataset bias for mri harmonisation and confound removal
Dinsdale, N. K., Jenkinson, M., & Namburete, A. I. L. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117689 · Cited by 178
Cetin Karayumak, S., Bouix, S., Ning, L., James, A., Crow, T., Shenton, M., Kubicki, M., & Rathi, Y. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.073 · Cited by 164
Self-citationThe sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Advances in microstructural diffusion neuroimaging for psychiatric disorders
Pasternak, O., Kelly, S., Sydnor, V. J., & Shenton, M. E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.04.051 · Cited by 116
Self-citationSchilling, K. G., Archer, D., Yeh, F.-C., Rheault, F., Cai, L. Y., Hansen, C., Yang, Q., Ramdass, K., Shafer, A. T., Resnick, S. M., et al. (2022) · Brain Structure and Function · doi:10.1007/s00429-022-02503-z · Cited by 78
“Combination of datasets in analysis requires either accounting for these effects in modeling (as performed here) or harmonizing data across scanners and sites, which is an active area of interest (36, 42, 43).”
MethodAzizi, S., Mousavi, P., Yan, P., Tahmasebi, A., Kwak, J. T., Xu, S., Turkbey, B., Choyke, P., Pinto, P., Wood, B., et al. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-017-1573-x · Cited by 30
Uncertainty Quantification in Deep Learning for Safer Neuroimage Enhancement
Tanno, R., Worrall, D., Kaden, E., Ghosh, A., Grussu, F., Bizzi, A., Sotiropoulos, S. N., Criminisi, A., & Alexander, D. C. (2019) · arXiv · doi:10.48550/arxiv.1907.13418 · Cited by 30
“, estimating T2-weighted images from T1 [130–132], estimating CT images from MRI [48,57,133], and generating a high-field scan from a low-field scan [51]; data harmonisation [14, 15, 134] which aims to learn mappings among imaging protocols to reduce confounds in multicentre studies.”
BackgroundRaven, E. P., Veraart, J., Kievit, R. A., Genc, S., Ward, I. L., Hall, J., Cunningham, A., Doherty, J., van den Bree, M. B. M., & Jones, D. K. (2023) · Molecular Psychiatry · doi:10.1038/s41380-023-02178-w · Cited by 21
Metadata
- Authors
- Mirzaalian, H., Ning, L., Savadjiev, P., Pasternak, O., Bouix, S., Michailovich, O., Grant, G., Marx, C. E., Morey, R. A., Flashman, L. A., George, M. S., McAllister, T. W., Andaluz, N., Shutter, L., Coimbra, R., Zafonte, R. D., Coleman, M. J., Kubicki, M., Westin, C. F., Stein, M. B., Shenton, M. E., & Rathi, Y.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2016-07
- Volume
- 135
- Pages
- 311-323
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2344337444
- Cited by
- 151
- References
- 11
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.