CoChat

Imaging of cerebral α4β2* nicotinic acetylcholine receptors with (−)-[18F]Flubatine PET: Implementation of bolus plus constant infusion and sensitivity to acetylcholine in human brain

Open access
Hillmer, A.T., Esterlis, I., Gallezot, J.D., Bois, F., Zheng, M.Q., Nabulsi, N., Lin, S.F., Papke, R.L., Huang, Y., Sabri, O., Carson, R.E., Cosgrove, K.P. · 2016 · NeuroImage
Cited by 99

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

The positron emission tomography (PET) radioligand (−)-[18F]flubatine is specific to α4β2∗ nicotinic acetylcholine receptors (nAChRs) and has promise for future investigation of the acetylcholine system in neuropathologies such as Alzheimer's disease, schizophrenia, and substance use disorders. The two goals of this work were to develop a simplified method for α4β2∗ nAChR quantification with bolus plus constant infusion (B/I) (−)-[18F]flubatine administration, and to assess the radioligand's sensitivity to acetylcholine fluctuations in humans. Healthy human subjects were imaged following either bolus injection (n = 8) or B/I (n = 4) administration of (−)-[18F]flubatine. The metabolite-corrected input function in arterial blood was measured. Free-fraction corrected distribution volumes (VT/fP) were estimated with modeling and graphical analysis techniques. Next, sensitivity to acetylcholine was assessed in two ways: 1. A bolus injection paradigm with two scans (n = 6), baseline (scan 1) and physostigmine challenge (scan 2; 1.5 mg over 60 min beginning 5 min prior to radiotracer injection); 2. A single scan B/I paradigm (n = 7) lasting up to 240 min with 1.5 mg physostigmine administered over 60 min beginning at 125 min of radiotracer infusion. Changes in VT/fP were measured. Baseline VT/fP values were 33.8 ± 3.3 mL/cm3 in thalamus, 12.9 ± 1.6 mL/cm3 in cerebellum, and ranged from 9.8 to 12.5 mL/cm3 in other gray matter regions. The B/I paradigm with equilibrium analysis at 120 min yielded comparable VT/fP values with compartment modeling analysis of bolus data in extrathalamic gray matter regions (regional means <4% different). Changes in VT/fP following physostigmine administration were small and most pronounced in cortical regions, ranging from 0.8 to 4.6% in the two-scan paradigm and 2.8 to 6.5% with the B/I paradigm. These results demonstrate the use of B/I administration for accurate quantification of (−)-[18F]flubatine VT/fP in 120 min, and suggest possible sensitivity of (−)-[18F]flubatine binding to physostigmine-induced changes in acetylcholine levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2016.07.026

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Hillmer, A. T., Esterlis, I., Gallezot, J. D., Bois, F., Zheng, M. Q., Nabulsi, N., Lin, S. F., Papke, R. L., Huang, Y., Sabri, O., Carson, R. E., & Cosgrove, K. P.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2016-11
Volume
141
Pages
71-80
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2505862500
Cited by
99
References
16
FWCI
1.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.