The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Longitudinal multiple sclerosis lesion segmentation: Resource and challenge
Open accessAbstract
In conjunction with the ISBI 2015 conference, we organized a longitudinal lesion segmentation challenge providing training and test data to registered participants. The training data consisted of five subjects with a mean of 4.4 time‐points, and test data of fourteen subjects with a mean of 4.4 time‐points. All 82 data sets had the white matter lesions associated with multiple sclerosis delineated by two human expert raters. Eleven teams submitted results using state‐of‐the‐art lesion segmentation algorithms to the challenge, with ten teams presenting their results at the conference. We present a quantitative evaluation comparing the consistency of the two raters as well as exploring the performance of the eleven submitted results in addition to three other lesion segmentation algorithms. The challenge presented three unique opportunities: (1) the sharing of a rich data set; (2) collaboration and comparison of the various avenues of research being pursued in the community; and (3) a review and refinement of the evaluation metrics currently in use. We report on the performance of the challenge participants, as well as the construction and evaluation of a consensus delineation. The image data and manual delineations will continue to be available for download, through an evaluation website2 as a resource for future researchers in the area. This data resource provides a platform to compare existing methods in a fair and consistent manner to each other and multiple manual raters. HighlightsPublic lesion data base of 21 training data sets and 61 testing data sets.Fully automated evaluation website.Comparison between 14 state‐of‐the‐art algorithms and 2 manual delineators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
Polman, C. H., Reingold, S. C., Banwell, B., Clanet, M., Cohen, J. A., Filippi, M., Fujihara, K., Havrdova, E., Hutchinson, M., Kappos, L., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22366 · Cited by 9,802
Geurts, P., Ernst, D., & Wehenkel, L. (2006) · Machine Learning · doi:10.1007/s10994-006-6226-1 · Cited by 9,300
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
Self-citationN4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
ADADELTA: An Adaptive Learning Rate Method
Zeiler, M. D. (2012) · arXiv · doi:10.48550/arxiv.1212.5701 · Cited by 5,322
Compston, A., & Coles, A. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61620-7 · Cited by 4,372
New Multiple Sclerosis Phenotypic Classification
Lublin, F. D. (2014) · European Neurology · doi:10.1159/000367614 · Cited by 4,259
VII. Note on regression and inheritance in the case of two parents
Pearson, K. (1895) · Proceedings of the Royal Society of London · doi:10.1098/rspl.1895.0041 · Cited by 3,424
Mazziotta, J., Toga, A., Evans, A., Fox, P., Lancaster, J., Zilles, K., Woods, R., Paus, T., Simpson, G., Pike, B., et al. (2001) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2001.0915 · Cited by 2,347
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
Self-citationDesign and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Diagnostic criteria for multiple sclerosis
Poser, C. M., & Brinar, V. V. (2001) · Clinical Neurology and Neurosurgery · doi:10.1016/s0303-8467(00)00125-6 · Cited by 1,283
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
An automated tool for detection of FLAIR-hyperintense white-matter lesions in Multiple Sclerosis
Schmidt, P., Gaser, C., Arsic, M., Buck, D., Förschler, A., Berthele, A., Hoshi, M., Ilg, R., Schmid, V. J., Zimmer, C., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.032 · Cited by 1,223
An Optimized Blockwise Non Local Means Denoising Filter for 3D Magnetic Resonance Images
Barillot, C., Inserm, H. I., & Barillot, C. (2007) · Cited by 1,208
Self-citationComparison and evaluation of methods for liver segmentation from CT datasets
Heimann, T., van Ginneken, B., Styner, M. A., Arzhaeva, Y., Aurich, V., Bauer, C., Beck, A., Becker, C., Beichel, R., Bekes, G., et al. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2013851 · Cited by 1,135
A Convergence Theorem for the Fuzzy ISODATA Clustering Algorithms
Bezdek, J. C. (1980) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1980.4766964 · Cited by 980
Supervised Dictionary Learning
Mairal, J., Bach, F., Ponce, J., Sapiro, G., & Zisserman, A. (2008) · arXiv (Cornell University) · doi:10.48550/arxiv.0809.3083 · Cited by 938
MRI simulation-based evaluation of image-processing and classification methods
Kwan, R. K.-S., Evans, A. C., & Pike, G. B. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816072 · Cited by 709
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
An Open Source Multivariate Framework for n-Tissue Segmentation with Evaluation on Public Data
Avants, B. B., Tustison, N. J., Wu, J., Cook, P. A., & Gee, J. C. (2011) · Neuroinformatics · doi:10.1007/s12021-011-9109-y · Cited by 576
The Generalized PatchMatch Correspondence Algorithm
Barnes, C., Shechtman, E., Goldman, D. B., & Finkelstein, A. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-15558-1_3 · Cited by 530
Maier, O., Menze, B. H., von der Gablentz, J., Häni, L., Heinrich, M. P., Liebrand, M., Winzeck, S., Basit, A., Bentley, P., Chen, L., et al. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.009 · Cited by 524
Self-citationMedical Image Processing, Analysis and Visualization in clinical research
McAuliffe, M. J., Lalonde, F. M., McGarry, D., Gandler, W., Csaky, K., & Trus, B. L. (2002) · Proceedings 14th IEEE Symposium on Computer-Based Medical Systems. CBMS 2001 · doi:10.1109/cbms.2001.941749 · Cited by 512
Automated segmentation of multiple sclerosis lesions by model outlier detection
Van Leemput, K., Maes, F., Vandermeulen, D., Colchester, A., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938237 · Cited by 489
Association between pathological and MRI findings in multiple sclerosis
Filippi, M., Rocca, M. A., Barkhof, F., Brück, W., Chen, J. T., Comi, G., DeLuca, G., De Stefano, N., Erickson, B. J., Evangelou, N., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70003-0 · Cited by 486
Avoiding asymmetry-induced bias in longitudinal image processing
Reuter, M., & Fischl, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.076 · Cited by 474
Brosch, T., Tang, L. Y. W., Yoo, Y., Li, D. K. B., Traboulsee, A., & Tam, R. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528821 · Cited by 460
Adaptive, template moderated, spatially varying statistical classification
Warfield, S. K., Kaus, M., Jolesz, F. A., & Kikinis, R. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00003-7 · Cited by 402
Self-citationGlobal image registration using a symmetric block-matching approach
Modat, M., Cash, D. M., Daga, P., Winston, G. P., Duncan, J. S., & Ourselin, S. (2014) · Journal of Medical Imaging · doi:10.1117/1.jmi.1.2.024003 · Cited by 374
Self-citationSchaap, M., Metz, C. T., van Walsum, T., van der Giessen, A. G., Weustink, A. C., Mollet, N. R., Bauer, C., Bogunović, H., Castro, C., Deng, X., et al. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.06.003 · Cited by 362
Self-citationGarcía-Lorenzo, D., Francis, S., Narayanan, S., Arnold, D. L., & Collins, D. L. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.004 · Cited by 355
Roth, H. R., Lu, L., Seff, A., Cherry, K. M., Hoffman, J., Wang, S., Liu, J., Turkbey, E., & Summers, R. M. (2014) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-10404-1_65 · Cited by 340
HeMIS: Hetero-Modal Image Segmentation
Havaei, M., Guizard, N., Chapados, N., & Bengio, Y. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_54 · Cited by 332 · cited 2×
“…et al., 2015, 2016; Deshpande et al., 2015; Dugas-Phocion et al., 2004; Elliott et al., 2013, 2014; Ferrari et al., 2003; Geremia et al., 2010; Havaei et al., 2016; Jain et al., 2015; Jog et al., 2015; Johnston et al., 1996; Kamber et al., 1996; Khayati et al., 2008; Rey et al., 1999, 2002;…”
A topology-preserving approach to the segmentation of brain images with multiple sclerosis lesions
Shiee, N., Bazin, P.-L., Ozturk, A., Reich, D. S., Calabresi, P. A., & Pham, D. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.005 · Cited by 331
Self-citationProbabilistic segmentation of white matter lesions in MR imaging
Anbeek, P., Vincken, K. L., van Osch, M. J. P., Bisschops, R. H. C., & van der Grond, J. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.10.012 · Cited by 321
Multiple sclerosis lesion quantification using fuzzy-connectedness principles
Udupa, J. K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M. A., & Grossman, R. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640750 · Cited by 314
MRBrainS Challenge: Online Evaluation Framework for Brain Image Segmentation in 3T MRI Scans
Mendrik, A. M., Vincken, K. L., Kuijf, H. J., Breeuwer, M., Bouvy, W. H., de Bresser, J., Alansary, A., de Bruijne, M., Carass, A., El-Baz, A., et al. (2015) · Computational Intelligence and Neuroscience · doi:10.1155/2015/813696 · Cited by 261
Self-citationSegmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
Segmentation of multiple sclerosis lesions in brain MRI: A review of automated approaches
Lladó, X., Oliver, A., Cabezas, M., Freixenet, J., Vilanova, J. C., Quiles, A., Valls, L., Ramió-Torrentà, L., & Rovira, À. (2012) · Information Sciences · doi:10.1016/j.ins.2011.10.011 · Cited by 240
Spatial decision forests for MS lesion segmentation in multi-channel magnetic resonance images
Geremia, E., Clatz, O., Menze, B. H., Konukoglu, E., Criminisi, A., & Ayache, N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.080 · Cited by 231
Automatic segmentation and volumetry of multiple sclerosis brain lesions from MR images
Jain, S., Sima, D. M., Ribbens, A., Cambron, M., Maertens, A., Van Hecke, W., De Mey, J., Barkhof, F., Steenwijk, M. D., Daams, M., et al. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.05.003 · Cited by 220
Self-citationRandom forest regression for magnetic resonance image synthesis
Jog, A., Carass, A., Roy, S., Pham, D. L., & Prince, J. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.009 · Cited by 212 · cited 1×
“Predicting entire neighborhoods gives further context information such as the presence of lesions predominantly inside WM, which has been shown to improve patch based methods (Jog et al., 2017).”
BackgroundModel-based 3-D segmentation of multiple sclerosis lesions in magnetic resonance brain images
Kamber, M., Shinghal, R., Collins, D. L., Francis, G. S., & Evans, A. C. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414608 · Cited by 211
Bosc, M., Heitz, F., Armspach, J.-P., Namer, I., Gounot, D., & Rumbach, L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00406-3 · Cited by 210
Rey, D., Subsol, G., Delingette, H., & Ayache, N. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00056-7 · Cited by 201
Quantitative assessment of MRI lesion load in monitoring the evolution of multiple sclerosis
Filippi, M., Horsfield, M. A., Tofts, P. S., Barkhof, F., Thompson, A. J., & Miller, D. H. (1995) · Brain · doi:10.1093/brain/118.6.1601 · Cited by 178
Towards realtime multimodal fusion for image-guided interventions using self-similarities
Heinrich, M. P., Jenkinson, M., Papież, B. W., Brady, S. M., & Schnabel, J. A. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40811-3_24 · Cited by 176
Evolution of the blood–brain barrier in newly forming multiple sclerosis lesions
Gaitán, M. I., Shea, C. D., Evangelou, I. E., Stone, R. D., Fenton, K. M., Bielekova, B., Massacesi, L., & Reich, D. S. (2011) · Annals of Neurology · doi:10.1002/ana.22472 · Cited by 174 · cited 1×
“MS frequently involves lesions that may be readily apparent on a scan at one time-point, but not in subsequent time-points (He et al., 2001; Gaitán et al., 2011; Qian et al., 2011).”
BackgroundSelf-citation3D Segmentation in the Clinic: A Grand Challenge II: MS lesion segmentation
Styner, M., Lee, J., Chin, B., Chin, M. S., Commowick, O., Tran, H.-H., Markovic-Plese, S., Jewells, V., & Warfield, S. (2008) · The MIDAS Journal · doi:10.54294/lmkqvm · Cited by 167
Self-citationExtra Tree forests for sub-acute ischemic stroke lesion segmentation in MR sequences
Maier, O., Wilms, M., von der Gablentz, J., Krämer, U. M., Münte, T. F., & Handels, H. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.11.011 · Cited by 162
Self-citationSudre, C. H., Cardoso, M. J., Bouvy, W. H., Biessels, G. J., Barnes, J., & Ourselin, S. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2419072 · Cited by 162
Self-citationLesion segmentation from multimodal MRI using random forest following ischemic stroke
Mitra, J., Bourgeat, P., Fripp, J., Ghose, S., Rose, S., Salvado, O., Connelly, A., Campbell, B. C. V., Palmer, S., Sharma, G. J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.04.056 · Cited by 160
MRI techniques to monitor MS evolution: The present and the future
Filippi, M., & Grossman, R. I. (2002) · Neurology · doi:10.1212/wnl.58.8.1147 · Cited by 155
Automated segmentation of multiple sclerosis lesion subtypes with multichannel MRI
Wu, Y. G., Warfield, S. K., Tan, I. L., Wells, W. M., Meier, D., van Schijndel, R. A., Barkhof, F., & Guttmann, C. R. G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.04.211 · Cited by 152
Self-citationThe Java Image Science Toolkit (JIST) for Rapid Prototyping and Publishing of Neuroimaging Software
Lucas, B. C., Bogovic, J., Carass, A., Bazin, P., Prince, J. L., Pham, D. L., & Landman, B. A. (2010) · Neuroinformatics · doi:10.1007/s12021-009-9061-2 · Cited by 133
Self-citationDeep Convolutional Encoder Networks for Multiple Sclerosis Lesion Segmentation
Brosch, T., Yoo, Y., Tang, L. Y. W., Li, D. K. B., Traboulsee, A. L., & Tam, R. C. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_1 · Cited by 127
MAGNIMS Study Group, Vrenken, H., Jenkinson, M., Horsfield, M. A., Battaglini, M., van Schijndel, R. A., Rostrup, E., Geurts, J. J. G., Fisher, E., Zijdenbos, A. P., et al. (2012) · Journal of Neurology · doi:10.1007/s00415-012-6762-5 · Cited by 124
CLASSIC: Consistent Longitudinal Alignment and Segmentation for Serial Image Computing
Xue, Z., Shen, D. G., & Davatzikos, C. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.054 · Cited by 122
Homeomorphic brain image segmentation with topological and statistical atlases
Bazin, P., & Pham, D. L. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.06.008 · Cited by 118
Self-citationUnified Approach for Multiple Sclerosis Lesion Segmentation on Brain MRI
Sajja, B. R., Datta, S., He, R., et al. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9009-0 · Cited by 116
Simple paradigm for extra-cerebral tissue removal: Algorithm and analysis
Carass, A., Cuzzocreo, J. L., Wheeler, M. B., Bazin, P., Resnick, S. M., & Prince, J. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.045 · Cited by 114
Self-citationSpatial Decision Forests for MS Lesion Segmentation in Multi-Channel MR Images
Geremia, E., Menze, B. H., Clatz, O., Konukoğlu, E., Criminisi, A., & Ayache, N. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15705-9_14 · Cited by 111
Sweeney, E. M., Shinohara, R. T., Shiee, N., Mateen, F. J., Chudgar, A. A., Cuzzocreo, J. L., Calabresi, P. A., Pham, D. L., Reich, D. S., & Crainiceanu, C. M. (2013) · NeuroImage Clinical · doi:10.1016/j.nicl.2013.03.002 · Cited by 103
Self-citationLi, H., Zhao, R., & Wang, X. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1412.4526 · Cited by 100
Enhancing patterns in multiple sclerosis: evolution and persistence.
He, J., Grossman, R. I., Ge, Y., & Mannon, L. J. (2001) · PubMed · Cited by 100
A toolbox for multiple sclerosis lesion segmentation
Roura, E., Oliver, A., Cabezas, M., Valverde, S., Pareto, D., Vilanova, J. C., Ramió‐Torrentà, L., Rovira, À., & Lladó, X. (2015) · Neuroradiology · doi:10.1007/s00234-015-1552-2 · Cited by 97
The Role of MRI in clinical trials of multiple sclerosis: Comparison of image processing techniques
Evans, A. C., Frank, J. A., Antel, J. P., & Miller, D. H. (1997) · Annals of Neurology · doi:10.1002/ana.410410123 · Cited by 91
Multiple Sclerosis Lesion Segmentation Using Dictionary Learning and Sparse Coding
Weiss, N., Rueckert, D., & Rao, A. W. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_92 · Cited by 84
The Clinical Epidemiology of Multiple Sclerosis
Confavreux, C., & Vukusic, S. (2008) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2008.09.002 · Cited by 84
Temporally Consistent Probabilistic Detection of New Multiple Sclerosis Lesions in Brain MRI
Elliott, C., Arnold, D. L., Collins, D. L., & Arbel, T. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2258403 · Cited by 79
Self-citationSubject-Specific Sparse Dictionary Learning for Atlas-Based Brain MRI Segmentation
Roy, S., He, Q., Sweeney, E. M., Carass, A., Reich, D. S., Prince, J. L., & Pham, D. L. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2439242 · Cited by 78
Self-citationAutomated tissue segmentation of MR brain images in the presence of white matter lesions
Valverde, S., Oliver, A., Roura, E., González-Villà, S., Pareto, D., Vilanova, J. C., Ramió‐Torrentà, L., Rovira, À., & Lladó, X. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.08.014 · Cited by 77
García-Lorenzo, D., Prima, S., Arnold, D. L., Collins, D. L., & Barillot, C. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2114671 · Cited by 76
Self-citationTomas-Fernandez, X., & Warfield, S. K. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2393853 · Cited by 73
Self-citationSTREM: A Robust Multidimensional Parametric Method to Segment MS Lesions in MRI
Aït-Ali, L., Prima, S., Pierre Hellier, J., Carsin-Nicol, B., Edan, G., & Barillot, C. (2005) · Lecture notes in computer science · doi:10.1007/11566465_51 · Cited by 70
Self-citationMagnetic resonance outcome measures in multiple sclerosis trials: time to rethink?
Filippi, M., Preziosa, P., & Rocca, M. A. (2014) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000095 · Cited by 68
MR contrast synthesis for lesion segmentation
Roy, S., Carass, A., Shiee, N., Pham, D. L., & Prince, J. L. (2010) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2010.5490140 · Cited by 61
Self-citationAutomated identification of brain new lesions in multiple sclerosis using subtraction images
Battaglini, M., Rossi, F., Grove, R. A., Stromillo, M. L., Whitcher, B. J., Matthews, P., & Stefano, N. D. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24293 · Cited by 58
Multiple Sclerosis Lesion Segmentation Using an Automatic Multimodal Graph Cuts
García-Lorenzo, D., Lecoeur, J., Arnold, D. L., Collins, D. L., & Barillot, C. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-04271-3_71 · Cited by 57
Self-citationMeier, D., Weiner, H. L., & Guttmann, C. R. G. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0701 · Cited by 56
Patch-Based Segmentation with Spatial Consistency: Application to MS Lesions in Brain MRI
Mechrez, R., Goldberger, J., & Greenspan, H. (2016) · International Journal of Biomedical Imaging · doi:10.1155/2016/7952541 · Cited by 51
Self-citationOptimized PatchMatch for Near Real Time and Accurate Label Fusion
Ta, V., Giraud, R., Collins, D. L., & Coupé, P. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-10443-0_14 · Cited by 50
Reconstruction of the human cerebral cortex robust to white matter lesions: Method and validation
Shiee, N., Bazin, P., Cuzzocreo, J. L., Ye, C., Kishore, B., Carass, A., Calabresi, P. A., Reich, D. S., Prince, J. L., & Pham, D. L. (2013) · Human Brain Mapping · doi:10.1002/hbm.22409 · Cited by 45
Self-citationAutomatic white matter lesion segmentation using an adaptive outlier detection method
Ong, K. H., Ramachandram, D., Mandava, R., & Shuaib, I. L. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.01.007 · Cited by 44
Multiple Sclerosis Lesion Detection Using Constrained GMM and Curve Evolution
Freifeld, O., Greenspan, H. K., & Goldberger, J. (2009) · International Journal of Biomedical Imaging · doi:10.1155/2009/715124 · Cited by 44
Self-citationClassification of multiple sclerosis lesions using adaptive dictionary learning
Deshpande, H., Maurel, P., & Barillot, C. (2015) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2015.05.003 · Cited by 38
Self-citationCan MS lesion stages be distinguished with MRI? A postmortem MRI and histopathology study
Jonkman, L. E., Soriano, A., Amor, S., Barkhof, F., van der Valk, P., Vrenken, H., & Geurts, J. J. G. (2015) · Journal of Neurology · doi:10.1007/s00415-015-7689-4 · Cited by 38
Rey, D., Subsol, G., Delingette, H., & Ayache, N. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48714-x_12 · Cited by 35
A robust Expectation-Maximization algorithm for Multiple Sclerosis lesion segmentation
García-Lorenzo, D., Prima, S., Morrissey, S., & Barillot, C. (2008) · doi:10.54294/1pbpd4 · Cited by 34
Self-citationSubject Specific Sparse Dictionary Learning for Atlas Based Brain MRI Segmentation
Roy, S., Carass, A., Prince, J. L., & Pham, D. L. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-10581-9_31 · Cited by 33
Self-citationSahraian, M. A., & Radue, E. W. (2007) · Springer eBooks · doi:10.1007/978-3-540-71372-2 · Cited by 31
Segmentation of multiple sclerosis lesions using support vector machines
Ferrari, R. J., Wei, X., Zhang, Y., Scott, J. N., & Mitchell, J. R. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.481377 · Cited by 20
Magnetic Resonance Imaging Advances in Multiple Sclerosis
Bakshi, R. (2005) · Journal of Neuroimaging · doi:10.1177/1051228405283362 · Cited by 19
Statistical Analysis of Longitudinal MRI Data: Applications for Detection of Disease Activity in MS
Prima, S., Ayache, N., Janke, A. L., Francis, S. J., Arnold, D. L., & Collins, D. L. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_45 · Cited by 17
Subbanna, N. K., Precup, D., Arnold, D. L., & Arbel, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-19992-4_40 · Cited by 17
Self-citationLongitudinal Patch-Based Segmentation of Multiple Sclerosis White Matter Lesions
Roy, S., Carass, A., Prince, J. L., & Pham, D. L. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24888-2_24 · Cited by 12
Self-citationRadiological Evaluation of Cerebral Aneurysms in Selected Clinical Presentations
Jabre, A. (2004) · Journal of Neuroimaging · doi:10.1177/1051228404268268 · Cited by 3
Heterogeneity in longitudinal evolution of ring‐enhancing multiple sclerosis lesions
Qian, P., Cadavid, D., Wolansky, L. J., Cook, S. D., & Naismith, R. T. (2011) · Annals of Neurology · doi:10.1002/ana.22622 · Cited by 3
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021) · Nature Methods · doi:10.1038/s41592-020-01008-z · Cited by 10,477
Domain adaptation for medical image analysis: A survey
Guan, H., & Liu, M. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3117407 · Cited by 1,057
Diffusion models in medical imaging: A comprehensive survey
Kazerouni, A., Aghdam, E. K., Heidari, M., Azad, R., Fayyaz, M., Hacihaliloglu, I., & Merhof, D. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102846 · Cited by 765
Deep learning with noisy labels: Exploring techniques and remedies in medical image analysis
Karimi, D., Dou, H., Warfield, S. K., & Gholipour, A. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101759 · Cited by 706
Self-citationNair, T., Precup, D., Arnold, D. L., & Arbel, T. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101557 · Cited by 451
Self-citation
Metadata
- Authors
- Carass, A., Roy, S., Jog, A., Cuzzocreo, J. L., Magrath, E., Gherman, A., Button, J., Nguyen, J., Prados, F., Sudre, C. H., Jorge Cardoso, M., Cawley, N., Ciccarelli, O., Wheeler-Kingshott, C. A. M., Ourselin, S., Catanese, L., Deshpande, H., Maurel, P., Commowick, O., Barillot, C., Tomas-Fernandez, X., Warfield, S. K., Vaidya, S., Chunduru, A., Muthuganapathy, R., Krishnamurthi, G., Jesson, A., Arbel, T., Maier, O., Handels, H., Iheme, L. O., Unay, D., Jain, S., Sima, D. M., Smeets, D., Ghafoorian, M., Platel, B., Birenbaum, A., Greenspan, H., Bazin, P.-L., Calabresi, P. A., Crainiceanu, C. M., Ellingsen, L. M., Reich, D. S., Prince, J. L., & Pham, D. L.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 148
- Pages
- 77-102
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2575552683
- Cited by
- 357
- References
- 106
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.