Diffusion time dependence of microstructural parameters in fixed spinal cord
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Biophysical modelling of diffusion MRI is necessary to provide specific microstructural tissue properties. However, estimating model parameters from data with limited diffusion gradient strength, such as clinical scanners, has proven unreliable due to a shallow optimization landscape. On the other hand, estimation of diffusion kurtosis (DKI) parameters is more robust, and its parameters may be connected to microstructural parameters, given an appropriate biophysical model. However, it was previously shown that this procedure still does not provide sufficient information to uniquely determine all model parameters. In particular, a parameter degeneracy related to the relative magnitude of intra-axonal and extra-axonal diffusivities remains. Here we develop a model of diffusion in white matter including axonal dispersion and demonstrate stable estimation of all model parameters from DKI in fixed pig spinal cord. By employing the recently developed fast axisymmetric DKI, we use stimulated echo acquisition mode to collect data over a two orders of magnitude diffusion time range with very narrow diffusion gradient pulses, enabling finely resolved measurements of diffusion time dependence of both net diffusion and kurtosis metrics, as well as model intra- and extra-axonal diffusivities, and axonal dispersion. Our results demonstrate substantial time dependence of all parameters except volume fractions, and the additional time dimension provides support for intra-axonal diffusivity to be larger than extra-axonal diffusivity in spinal cord white matter, although not unambiguously. We compare our findings for the time-dependent compartmental diffusivities to predictions from effective medium theory with reasonable agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 21×
“Using axisymmetric DKI, we were able to estimate radial and axial diffusivity, as well as radial, axial and mean kurtosis.”
InfluentialGibbs-ringing artifact removal based on local subvoxel-shifts
Kellner, E., Dhital, B., Kiselev, V. G., & Reisert, M. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26054 · Cited by 1,478 · cited 1×
“The raw images were denoised (Veraart et al., 2016a) and corrected for Gibbs ringing (Kellner et al., 2016) before the subsequent analysis.”
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856 · cited 1×
“Hence, estimating all parameters of complex microstructural models robustly is likely to require comprehensive data sets including very high diffusion weighting, which is feasible only on specialized scanners and mostly ex vivo (Alexander et al., 2010; Assaf and Basser, 2005; Assaf et al., 2008; Jespersen et al., 2007…”
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 1×
“Hence, estimating all parameters of complex microstructural models robustly is likely to require comprehensive data sets including very high diffusion weighting, which is feasible only on specialized scanners and mostly ex vivo (Alexander et al., 2010; Assaf and Basser, 2005; Assaf et al., 2008; Jespersen et al., 2007…”
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683 · cited 2×
“…models robustly is likely to require comprehensive data sets including very high diffusion weighting, which is feasible only on specialized scanners and mostly ex vivo (Alexander et al., 2010; Assaf and Basser, 2005; Assaf et al., 2008; Jespersen et al., 2007a; Jespersen et al., 2010).”
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Self-citationWhite matter characterization with diffusional kurtosis imaging
Fieremans, E., Jensen, J. H., & Helpern, J. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.006 · Cited by 561
Degeneracy in model parameter estimation for multi‐compartmental diffusion in neuronal tissue
Jelescu, I. O., Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3450 · Cited by 316 · cited 2×
“Since this range roughly corresponds to the range typically probed on clinical scanners, this degeneracy is fundamentally related to the difficulty of estimating parameters of microstructural models from clinical data in general (Jelescu et al., 2016).”
Jespersen, S. N., Bjarkam, C. R., Nyengaard, J. R., Chakravarty, M. M., Hansen, B., Vosegaard, T., Østergaard, L., Yablonskiy, D., Nielsen, N. C., & Vestergaard-Poulsen, P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.053 · Cited by 290
Self-citation
Cited by
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Self-citationNovikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Self-citationDesign and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240
“For example, using WMTI, AWF has been shown to correlate with axon volume fraction but not with the g-ratio derived from EM, while De,⊥ correlated with the g-ratio but not the with axon volume fraction [56].”
InfluentialNovikov, D. S., Veraart, J., Jelescu, I. O., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.006 · Cited by 237
“Recent time-dependent diffusion study (Jespersen et al., 2017) in fixed porcine spinal cord favors the ζ ¼ þ branch.”
BackgroundHuang, S. Y., Witzel, T., Keil, B., Scholz, A., Davids, M., Dietz, P., Rummert, E., Ramb, R., Kirsch, J. E., Yendiki, A., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118530 · Cited by 181
Jelescu, I. O., de Skowronski, A., Geffroy, F., Palombo, M., & Novikov, D. S. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119277 · Cited by 177
Diffusion time dependence, power‐law scaling, and exchange in gray matter
Olesen, J. L., Østergaard, L., Shemesh, N., & Jespersen, S. N. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118976 · Cited by 125
“This is slightly surprising in the context of the recent branchdebate in WM modelling (closely related to the relative values of the intra-axonal and extracellular diffusivities), because the consensus is that the intra-axonal diffusivity is largest (Fieremans et al., 2011; Dhital et al., 2018, 2019; Jespersen et al.,…”
BackgroundSelf-citationOptimizing the intrinsic parallel diffusivity in NODDI: an extensive empirical evaluation
Guerrero, J. M., Adluru, N., Bendlin, B. B., Goldsmith, H. H., Schaefer, S. M., Davidson, R. J., Kecskemeti, S. R., Zhang, H., & Alexander, A. L. (2019) · PLOS ONE · doi:10.1371/journal.pone.0217118 · Cited by 98
Lampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Hansson, O., Westin, C., & Nilsson, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28216 · Cited by 86
Coelho, S., Pozo, J. M., Jespersen, S. N., Jones, D. K., & Frangi, A. F. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27714 · Cited by 76
Self-citationA unique analytical solution of the white matter standard model using linear and planar encodings
Reisert, M., Kiselev, V. G., & Dhital, B. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27685 · Cited by 46
“The intra‐axonal parameters are expressed from Equations (16) and (17),”
BackgroundWhite matter biomarkers from diffusion MRI
Nørhøj Jespersen, S. (2018) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2018.03.001 · Cited by 34
Diffusion Kurtosis Imaging maps neural damage in the EAE model of multiple sclerosis
Chuhutin, A., Hansen, B., Wlodarczyk, A., Owens, T., Shemesh, N., & Jespersen, S. N. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116406 · Cited by 3
Self-citation
Metadata
- Authors
- Jespersen, S. N., Olesen, J. L., Hansen, B., & Shemesh, N.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 182
- Pages
- 329-342
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2963028315
- Cited by
- 122
- References
- 20
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.