The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Automatic skull segmentation from MR images for realistic volume conductor models of the head: Assessment of the state-of-the-art
Open accessAbstract
Anatomically realistic volume conductor models of the human head are important for accurate forward modeling of the electric field during transcranial brain stimulation (TBS), electro‐ (EEG) and magnetoencephalography (MEG). In particular, the skull compartment exerts a strong influence on the field distribution due to its low conductivity, suggesting the need to represent its geometry accurately. However, automatic skull reconstruction from structural magnetic resonance (MR) images is difficult, as compact bone has a very low signal in magnetic resonance imaging (MRI). Here, we evaluate three methods for skull segmentation, namely FSL BET2, the unified segmentation routine of SPM12 with extended spatial tissue priors, and the skullfinder tool of BrainSuite. To our knowledge, this study is the first to rigorously assess the accuracy of these state‐of‐the‐art tools by comparison with CT‐based skull segmentations on a group of ten subjects. We demonstrate several key factors that improve the segmentation quality, including the use of multi‐contrast MRI data, the optimization of the MR sequences and the adaptation of the parameters of the segmentation methods. We conclude that FSL and SPM12 achieve better skull segmentations than BrainSuite. The former methods obtain reasonable results for the upper part of the skull when a combination of T1‐ and T2‐weighted images is used as input. The SPM12‐based results can be improved slightly further by means of simple morphological operations to fix local defects. In contrast to FSL BET2, the SPM12‐based segmentation with extended spatial tissue priors and the BrainSuite‐based segmentation provide coarse reconstructions of the vertebrae, enabling the construction of volume conductor models that include the neck. We exemplarily demonstrate that the extended models enable a more accurate estimation of the electric field distribution during transcranial direct current stimulation (tDCS) for montages that involve extraencephalic electrodes. The methods provided by FSL and SPM12 are integrated into pipelines for the automatic generation of realistic head models based on tetrahedral meshes, which are distributed as part of the open‐source software package SimNIBS for field calculations for transcranial brain stimulation. HIGHLIGHTSAssessment of three methods for the automatic skull segmentation from MR images.Rigorous test of their accuracy by comparison against CT data of the same subjects.FSL and SPM12 can achieve reasonable accuracy for the upper part of the head.A combination of T1‐ and T2‐weighted images, rather than a single T1, is suggested.Accuracy strongly benefits from optimization of the MRI sequence parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
Gmsh: A 3‐D finite element mesh generator with built‐in pre‐ and post‐processing facilities
Geuzaine, C., & Remacle, J. (2009) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.2579 · Cited by 7,814
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
scikit-image: image processing in Python
van der Walt, S., Schönberger, J. L., Nunez-Iglesias, J., Boulogne, F., Warner, J. D., Yager, N., Gouillart, E., & Yu, T. (2014) · PeerJ · doi:10.7717/peerj.453 · Cited by 6,794
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147
Digital Image Processing: PIKS Inside
Pratt, W. K. (2002) · Wiley eBooks · doi:10.1002/0471221325 · Cited by 4,340
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Efficient multi-scale 3D CNN with fully connected CRF for accurate brain lesion segmentation
Kamnitsas, K., Ledig, C., Newcombe, V. F. J., Simpson, J. P., Kane, A. D., Menon, D. K., Rueckert, D., & Glocker, B. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.10.004 · Cited by 3,498
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
A modified Hausdorff distance for object matching
Dubuisson, M.-P., & Jain, A. K. (2002) · Proceedings of 12th International Conference on Pattern Recognition · doi:10.1109/icpr.1994.576361 · Cited by 1,464
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Magnetic Resonance Image Tissue Classification Using a Partial Volume Model
Shattuck, D. W., Sandor-Leahy, S. R., Schaper, K. A., Rottenberg, D. A., & Leahy, R. M. (2001) · NeuroImage · doi:10.1006/nimg.2000.0730 · Cited by 950
Thielscher, A., Antunes, A., & Saturnino, G. B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318340 · Cited by 942
Self-citationBrainSuite: An automated cortical surface identification tool
Shattuck, D. W., & Leahy, R. M. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00054-3 · Cited by 859
Cortical thickness and central surface estimation
Dahnke, R., Yotter, R. A., & Gaser, C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.050 · Cited by 709
Automated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Efficient Implementation of Marching Cubes' Cases with Topological Guarantees
Lewiner, T., Lopes, H., Vieira, A. W., & Tavares, G. (2003) · Journal of Graphics Tools · doi:10.1080/10867651.2003.10487582 · Cited by 520
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
Wolters, C. H., Anwander, A., Tricoche, X., Weinstein, D., Koch, M. A., & MacLeod, R. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452
Windhoff, M., Opitz, A., & Thielscher, A. (2013) · Human Brain Mapping · doi:10.1002/hbm.21479 · Cited by 441
Self-citationDatta, A., Baker, J. M., Bikson, M., & Fridriksson, J. (2011) · Brain Stimulation · doi:10.1016/j.brs.2010.11.001 · Cited by 325
A guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
Modeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
On the importance of electrode parameters for shaping electric field patterns generated by tDCS
Saturnino, G. B., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.067 · Cited by 263
Self-citation3D finite element meshing from imaging data
Zhang, Y., Bajaj, C., & Sohn, B.-S. (2005) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2004.11.026 · Cited by 187
Automated MRI segmentation for individualized modeling of current flow in the human head
Huang, Y., Dmochowski, J. P., Su, Y., Datta, A., Rorden, C., & Parra, L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066004 · Cited by 162
Comparison of three-shell and simplified volume conductor models in magnetoencephalography
Stenroos, M., Hunold, A., & Haueisen, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.006 · Cited by 149
Segmentation of skull and scalp in 3‐D human MRI using mathematical morphology
Dogdas, B., Shattuck, D. W., & Leahy, R. M. (2005) · Human Brain Mapping · doi:10.1002/hbm.20159 · Cited by 143
Head model and electrical source imaging: A study of 38 epileptic patients
Birot, G., Spinelli, L., Vulliémoz, S., Mégevand, P., Brunet, D., Seeck, M., & Michel, C. M. (2014) · NeuroImage Clinical · doi:10.1016/j.nicl.2014.06.005 · Cited by 125
Minjoli, S., Saturnino, G. B., Blicher, J. U., Stagg, C. J., Siebner, H. R., Antunes, A., & Thielscher, A. (2017) · NeuroImage Clinical · doi:10.1016/j.nicl.2017.04.014 · Cited by 123
Self-citationInfluence of the head model on EEG and MEG source connectivity analyses
Cho, J., Vorwerk, J., Wolters, C. H., & Knösche, T. R. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.043 · Cited by 122
Eggert, L. D., Sommer, J. B., Jansen, A., Kircher, T. T. J., & Konrad, C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045081 · Cited by 116
Influences of skull segmentation inaccuracies on EEG source analysis
Lanfer, B., Scherg, M., Dannhauer, M., Knösche, T. R., Burger, M., & Wolters, C. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.006 · Cited by 112
Aydın, Ü., Vorwerk, J., Küpper, P., Heers, M., Kugel, H., Galka, A., Hamid, L., Wellmer, J., Kellinghaus, C., Rampp, S., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093154 · Cited by 100
Stenroos, M., & Nummenmaa, A. R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159595 · Cited by 77
The role of blood vessels in high-resolution volume conductor head modeling of EEG
Fiederer, L. D. J., Vorwerk, J., Lucka, F. F., Dannhauer, M., Yang, S., Dümpelmann, M., Schulze‐Bonhage, A., Aertsen, A., Speck, O., Wolters, C. H., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.041 · Cited by 62
Determination of head conductivity frequency response in vivo with optimized EIT-EEG
Dabek, J., Kalogianni, K., Rotgans, E., van der Helm, F. C. T., Kwakkel, G., van Wegen, E. E. H., Daffertshofer, A., & de Munck, J. C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.023 · Cited by 49
A finite-element reciprocity solution for EEG forward modeling with realistic individual head models
Ziegler, E., Chellappa, S., Gaggioni, G., Ly, J. Q. M., Vandewalle, G., André, E., Geuzaine, C., & Phillips, C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.08.056 · Cited by 34
Eichelbaum, S., Dannhauer, M., Hlawitschka, M., Brooks, D. H., Knösche, T. R., & Scheuermann, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.04.085 · Cited by 28
Perdue, K. L., & Diamond, S. G. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.2.026011 · Cited by 26
Indahlastari, A., Chauhan, M., Schwartz, B., & Sadleir, R. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066006 · Cited by 25
Cited by
Immediate neurophysiological effects of transcranial electrical stimulation
Liu, A., Vöröslakos, M., Kronberg, G., Henin, S., Krause, M. R., Huang, Y., Opitz, A., Mehta, A., Pack, C. C., Krekelberg, B., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07233-7 · Cited by 589
Huang, Y., Datta, A., Bikson, M., & Parra, L. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab208d · Cited by 362
Saturnino, G. B., Puonti, O., Nielsen, J. D., Antonenko, D., Madsen, K. H., & Thielscher, A. (2019) · Brain and Human Body Modeling · doi:10.1007/978-3-030-21293-3_1 · Cited by 337
Self-citationCaulfield, K. A., Fleischmann, H. H., Cox, C. E., Wolf, J. P., George, M. S., & McTeague, L. M. (2022) · Brain Stimulation · doi:10.1016/j.brs.2022.08.013 · Cited by 145
“E-fieldmodeling is an approach that uses each person's individual MRI scans, segmented tissue layers, and tissue conductivities, to simulate how much noninvasive stimulation reaches the cortex [22].”
Influential
Metadata
- Authors
- Nielsen, J. D., Madsen, K. H., Puonti, O., Siebner, H. R., Bauer, C., Madsen, C. G., Saturnino, G. B., & Thielscher, A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 174
- Pages
- 587-598
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2791427514
- Cited by
- 271
- References
- 52
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.