Sub-millimeter ECoG pitch in human enables higher fidelity cognitive neural state estimation
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Electrocorticography (ECoG), electrophysiological recording from the pial surface of the brain, is a critical measurement technique for clinical neurophysiology, basic neurophysiology studies, and demonstrates great promise for the development of neural prosthetic devices for assistive applications and the treatment of neurological disorders. Recent advances in device engineering are poised to enable orders of magnitude increase in the resolution of ECoG without comprised measurement quality. This enhancement in cortical sensing enables the observation of neural dynamics from the cortical surface at the micrometer scale. While these technical capabilities may be enabling, the extent to which finer spatial scale recording enhances functionally relevant neural state inference is unclear. We examine this question by employing a high‐density and low impedance 400&mgr;m pitch microECoG (&mgr;ECoG) grid to record neural activity from the human cortical surface during cognitive tasks. By applying machine learning techniques to classify task conditions from the envelope of high‐frequency band (70–170Hz) neural activity collected from two study participants, we demonstrate that higher density grids can lead to more accurate binary task condition classification. When controlling for grid area and selecting task informative sub‐regions of the complete grid, we observed a consistent increase in mean classification accuracy with higher grid density; in particular, 400&mgr;m pitch grids outperforming spatially sub‐sampled lower density grids up to 23%. We also introduce a modeling framework to provide intuition for how spatial properties of measurements affect the performance gap between high and low density grids. To our knowledge, this work is the first quantitative demonstration of human sub‐millimeter pitch cortical surface recording yielding higher‐fidelity state estimation relative to devices at the millimeter‐scale, motivating the development and testing of &mgr;ECoG for basic and clinical neurophysiology as well as towards the realization of high‐performance neural prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Induced electrocorticographic gamma activity during auditory perception
Crone, N. E., Boatman, D., Gordon, B., & Hao, L. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00545-9 · Cited by 494
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278 · cited 1×
“Novel devices also demonstrate the integration of flexible electronics on these substrates, which could result in a new generation of ultra-high density probes with 1,000s to 10,000s of electrodes (Fang et al., 2017; Viventi et al., 2011).”
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
Thin-film, high-density micro-electrocorticographic decoding of a human cortical gyrus
Muller, L., Felix, S., Shah, K. G., Lee, K., Pannu, S., & Chang, E. F. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591001 · Cited by 15 · cited 11×
“An illustrative model with properties motivated from previous studies (Insanally et al., 2016; Kellis et al., 2016; Muller et al., 2016b; Trumpis et al., 2017) was developed to determine under what conditions a higher density grid might outperform a lower density grid.”
Influential
Cited by
Large-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex
Paulk, A. C., Kfir, Y., Khanna, A. R., Mustroph, M. L., Trautmann, E. M., Soper, D. J., Stavisky, S. D., Welkenhuysen, M., Dutta, B., Shenoy, K. V., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-021-00997-0 · Cited by 283
Davids, J., Manivannan, S., Darzi, A., Giannarou, S., Ashrafian, H., & Marcus, H. J. (2021) · Neurosurgical Review · doi:10.1007/s10143-020-01378-0 · Cited by 106
Challenges for Large-Scale Cortical Interfaces
Nurmikko, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.015 · Cited by 68
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“High-density electrode arrays have shown promise in both neurophysiological monitoring [48] and therapeutic neurostimulation [114].”
Metadata
- Authors
- Hermiz, J., Rogers, N., Kaestner, E., Ganji, M., Cleary, D. R., Carter, B. S., Barba, D., Dayeh, S. A., Halgren, E., & Gilja, V.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 176
- Pages
- 454-464
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2801605834
- Cited by
- 33
- References
- 6
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.