CoChat

Sub-millimeter ECoG pitch in human enables higher fidelity cognitive neural state estimation

Open access
Hermiz, John, Rogers, Nicholas, Kaestner, Erik, Ganji, Mehran, Cleary, Daniel R., Carter, Bob S., Barba, David, Dayeh, Shadi A., Halgren, Eric, Gilja, Vikash · 2018 · NeuroImage
Cited by 33

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Electrocorticography (ECoG), electrophysiological recording from the pial surface of the brain, is a critical measurement technique for clinical neurophysiology, basic neurophysiology studies, and demonstrates great promise for the development of neural prosthetic devices for assistive applications and the treatment of neurological disorders. Recent advances in device engineering are poised to enable orders of magnitude increase in the resolution of ECoG without comprised measurement quality. This enhancement in cortical sensing enables the observation of neural dynamics from the cortical surface at the micrometer scale. While these technical capabilities may be enabling, the extent to which finer spatial scale recording enhances functionally relevant neural state inference is unclear. We examine this question by employing a high‐density and low impedance 400&mgr;m pitch microECoG (&mgr;ECoG) grid to record neural activity from the human cortical surface during cognitive tasks. By applying machine learning techniques to classify task conditions from the envelope of high‐frequency band (70–170Hz) neural activity collected from two study participants, we demonstrate that higher density grids can lead to more accurate binary task condition classification. When controlling for grid area and selecting task informative sub‐regions of the complete grid, we observed a consistent increase in mean classification accuracy with higher grid density; in particular, 400&mgr;m pitch grids outperforming spatially sub‐sampled lower density grids up to 23%. We also introduce a modeling framework to provide intuition for how spatial properties of measurements affect the performance gap between high and low density grids. To our knowledge, this work is the first quantitative demonstration of human sub‐millimeter pitch cortical surface recording yielding higher‐fidelity state estimation relative to devices at the millimeter‐scale, motivating the development and testing of &mgr;ECoG for basic and clinical neurophysiology as well as towards the realization of high‐performance neural prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2018.04.027

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 33

Metadata

Authors
Hermiz, J., Rogers, N., Kaestner, E., Ganji, M., Cleary, D. R., Carter, B. S., Barba, D., Dayeh, S. A., Halgren, E., & Gilja, V.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2018-08
Volume
176
Pages
454-464
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2801605834
Cited by
33
References
6
FWCI
1.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.