The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Microstructural imaging of the human brain with a ‘super-scanner’: 10 key advantages of ultra-strong gradients for diffusion MRI
Open accessAbstract
The key component of a microstructural diffusion MRI ‘super‐scanner’ is a dedicated high‐strength gradient system that enables stronger diffusion weightings per unit time compared to conventional gradient designs. This can, in turn, drastically shorten the time needed for diffusion encoding, increase the signal‐to‐noise ratio, and facilitate measurements at shorter diffusion times. This review, written from the perspective of the UK National Facility for In Vivo MR Imaging of Human Tissue Microstructure, an initiative to establish a shared 300 mT/m‐gradient facility amongst the microstructural imaging community, describes ten advantages of ultra‐strong gradients for microstructural imaging. Specifically, we will discuss how the increase of the accessible measurement space compared to a lower‐gradient systems (in terms of &Dgr;, b‐value, and TE) can accelerate developments in the areas of 1) axon diameter distribution mapping; 2) microstructural parameter estimation; 3) mapping micro‐vs macroscopic anisotropy features with gradient waveforms beyond a single pair of pulsed‐gradients; 4) multi‐contrast experiments, e.g. diffusion‐relaxometry; 5) tractography and high‐resolution imaging in vivo and 6) post mortem; 7) diffusion‐weighted spectroscopy of metabolites other than water; 8) tumour characterisation; 9) functional diffusion MRI; and 10) quality enhancement of images acquired on lower‐gradient systems. We finally discuss practical barriers in the use of ultra‐strong gradients, and provide an outlook on the next generation of ‘super‐scanners’. HighlightsImproved estimation of axon diameter in vivo.Better fitting of complex microstructure models.Improved characterisation of tumours.Facilitation of multi‐contrast MRI experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Self-citationWhite matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationTournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586 · cited 1×
“, 2016) The advent of faster sequences such as multiband imaging, aka simultaneous multi-slice (Moeller et al., 2010), can help, but a significant boost in SNR is the only way to make these experiments practical.”
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 2×
“, 2015), “MR Fingerprinting” (Ma et al., 2013; Ma, Wright, Seiberlich, Gulani, & Griswold, 2014) and other techniques have the potential to capture the essential information while further reducing acquisition times.”
Tractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,376
Self-citation
Cited by
SANDI: a compartment‐based model for non‐invasive apparent soma and neurite imaging by diffusion MRI
Palombo, M., Ianus, A., Guerreri, M., Nunes, D., Alexander, D. C., Shemesh, N., & Zhang, H. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116835 · Cited by 349
Self-citationVariation in Reported Human Head Tissue Electrical Conductivity Values
McCann, H., Pisano, G., & Beltrachini, L. (2019) · Brain Topography · doi:10.1007/s10548-019-00710-2 · Cited by 293
Mapping microglia and astrocyte activation in vivo using diffusion MRI
Garcia-Hernandez, R., Cerdán Cerdá, A., Trouve Carpena, A., Drakesmith, M., Koller, K., Jones, D. K., Canals, S., & De Santis, S. (2022) · Science Advances · doi:10.1126/sciadv.abq2923 · Cited by 102
Self-citationEstimating axon conduction velocity in vivo from microstructural MRI
Drakesmith, M., Harms, R., Rudrapatna, S. U., Parker, G. D., Evans, C. J., & Jones, D. K. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116186 · Cited by 83
Self-citationLigneul, C., Palombo, M., Hernández-Garzón, E., Carrillo-de Sauvage, M.-A., Flament, J., Hantraye, P., Brouillet, E., Bonvento, G., Escartin, C., & Valette, J. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.046 · Cited by 77
Self-citationCoelho, S., Pozo, J. M., Jespersen, S. N., Jones, D. K., & Frangi, A. F. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27714 · Cited by 76
Self-citationRaven, E. P., Veraart, J., Kievit, R. A., Genc, S., Ward, I. L., Hall, J., Cunningham, A., Doherty, J., van den Bree, M. B. M., & Jones, D. K. (2023) · Molecular Psychiatry · doi:10.1038/s41380-023-02178-w · Cited by 21
Self-citationDissecting whole-brain conduction delays through MRI microstructural measures
Mancini, M., Tian, Q., Fan, Q., Cercignani, M., & Huang, S. Y. (2021) · Brain Structure and Function · doi:10.1007/s00429-021-02358-w · Cited by 20
Self-citationEngineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Metadata
- Authors
- Jones, D. K., Alexander, D. C., Bowtell, R., Cercignani, M., Dell'Acqua, F., McHugh, D. J., Miller, K. L., Palombo, M., Parker, G. J. M., Rudrapatna, U. S., & Tax, C. M. W.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 182
- Pages
- 8-38
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2803916235
- Cited by
- 183
- References
- 37
- FWCI
- 12.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.