Optimal referencing for stereo-electroencephalographic (SEEG) recordings
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
&NA; Stereo‐electroencephalography (SEEG) is an intracranial recording technique in which depth electrodes are inserted in the brain as part of presurgical assessments for invasive brain surgery. SEEG recordings can tap into neural signals across the entire brain and thereby sample both cortical and subcortical sites. However, even though signal referencing is important for proper assessment of SEEG signals, no previous study has comprehensively evaluated the optimal referencing method for SEEG. In our study, we recorded SEEG data from 15 human subjects during a motor task, referencing them against the average of two white matter contacts (monopolar reference). We then subjected these signals to 5 different re‐referencing approaches: common average reference (CAR), gray‐white matter reference (GWR), electrode shaft reference (ESR), bipolar reference, and Laplacian reference. The results from three different signal quality metrics suggest the use of the Laplacian re‐reference for study of local population‐level activity and low‐frequency oscillatory activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Desikan, R. S., Ségonne, F., Fischl, B., Quinn, B. T., Dickerson, B. C., Blacker, D., Buckner, R. L., Dale, A. M., Maguire, R. P., Hyman, B. T., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.021 · Cited by 13,324
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Alpha-band oscillations, attention, and controlled access to stored information
Klimesch, W. (2012) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2012.10.007 · Cited by 3,310
Different Origins of Gamma Rhythm and High-Gamma Activity in Macaque Visual Cortex
Ray, S., & Maunsell, J. H. R. (2011) · PLoS Biology · doi:10.1371/journal.pbio.1000610 · Cited by 1,012
Electrophysiological correlates of the brain's intrinsic large-scale functional architecture
He, B. J., Snyder, A. Z., Zempel, J. M., Smyth, M. D., & Raichle, M. E. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807010105 · Cited by 670 · cited 1×
“The Laplacian is one of the most widely-adopted re-referencing methods and is often used with EEG and local field potentials (LFPs) recorded with micro-electrode arrays (McFarland et al., 1997; He et al., 2008; Nunez and Westdorp, 1994; Shirhatti et al., 2016).”
MethodSignal quality of simultaneously recorded invasive and non-invasive EEG
Ball, T., Kern, M., Mutschler, I., Aertsen, A., & Schulze-Bonhage, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.028 · Cited by 403
Oscillatory phase modulates the timing of neuronal activations and resulting behavior
Coon, W. G., Gunduz, A., Brunner, P., Ritaccio, A. L., Pesaran, B., & Schalk, G. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.080 · Cited by 41 · cited 1×
“, 2017) and the performance of resulting behavior (Coon et al., 2016).”
BackgroundSelf-citation
Cited by
Cogitate Consortium, Ferrante, O., Gorska-Klimowska, U., Henin, S., Hirschhorn, R., Khalaf, A., Lepauvre, A., Liu, L., Richter, D., Vidal, Y., et al. (2025) · Nature · doi:10.1038/s41586-025-08888-1 · Cited by 136
“Electrodes were re-referenced to a Laplacian scheme 69 , whereas bipolar referencing was used for electrodes at the edge of a strip, grid or stereo EEG, and the signal was localized at the midpoint (Euclidean distance) between the two electrodes.”
An adversarial collaboration to critically evaluate theories of consciousness
Cogitate Consortium, Ferrante, O., Gorska-Klimowska, U., Henin, S., Hirschhorn, R., Khalaf, A., Lepauvre, A., Liu, L., Richter, D., Vidal, Y., et al. (2023) · doi:10.1101/2023.06.23.546249 · Cited by 86
Soroush, P. Z., Herff, C., Ries, S. K., Shih, J. J., Schultz, T., & Krusienski, D. J. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.119913 · Cited by 48
Metadata
- Authors
- Li, G., Jiang, S., Paraskevopoulou, S. E., Wang, M., Xu, Y., Wu, Z., Chen, L., Zhang, D., & Schalk, G.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 183
- Pages
- 327-335
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2887978199
- Cited by
- 159
- References
- 7
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal referencing for stereo-electroencephalographic (SEEG) recordings. https://app.cochat.ai/papers/10.1016/j.neuroimage.2018.08.020
- The paper
- Li, G., Jiang, S., Paraskevopoulou, S. E., Wang, M., Xu, Y., Wu, Z., Chen, L., Zhang, D., & Schalk, G. (2018). Optimal referencing for stereo-electroencephalographic (SEEG) recordings. NeuroImage. https://doi.org/10.1016/j.neuroimage.2018.08.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.