Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Open accessAbstract
One of the most severe limitations of functional neuroimaging techniques, such as magnetoencephalography (MEG), is that participants must maintain a fixed head position during data acquisition. This imposes restrictions on the characteristics of the experimental cohorts that can be scanned and the experimental questions that can be addressed. For these reasons, the use of 'wearable' neuroimaging, in which participants can move freely during scanning, is attractive. The most successful example of wearable neuroimaging is electroencephalography (EEG), which employs lightweight and flexible instrumentation that makes it useable in almost any experimental setting. However, EEG has major technical limitations compared to MEG, and therefore the development of wearable MEG, or hybrid MEG/EEG systems, is a compelling prospect. In this paper, we combine and compare EEG and MEG measurements, the latter made using a new generation of optically-pumped magnetometers (OPMs). We show that these new second generation commercial OPMs, can be mounted on the scalp in an 'EEG-like' cap, enabling the acquisition of high fidelity electrophysiological measurements. We show that these sensors can be used in conjunction with conventional EEG electrodes, offering the potential for the development of hybrid MEG/EEG systems. We compare concurrently measured signals, showing that, whilst both modalities offer high quality data in stationary subjects, OPM-MEG measurements are less sensitive to artefacts produced when subjects move. Finally, we show using simulations that OPM-MEG offers a fundamentally better spatial specificity than EEG. The demonstrated technology holds the potential to revolutionise the utility of functional brain imaging, exploiting the flexibility of wearable systems to facilitate hitherto impractical experimental paradigms.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
MEG has lower sensitivity to non-neuronal artefacts than EEG.
“and lower sensitivity to non-neuronal artefacts [17].”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [17]
The Discussion reports that MEG is less susceptible to muscle artefacts than EEG, and that OPM-MEG recordings degraded less during head movement. Those passages support the comparison for muscle- and movement-related artefacts, but do not establish lower sensitivity to non-neuronal artefacts generally or for all forms of MEG. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · see citing works
Self-citationCohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · see citing works
Whitham, E. M., Pope, K. J., Fitzgibbon, S. P., Lewis, T., Clark, C. R., Loveless, S., Broberg, M., Wallace, A., DeLosAngeles, D., Lillie, P., et al. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.027 · Cited by 524 · see citing works
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471 · see citing works
Self-citationOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400 · see citing works
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 2× · see citing works
“With scalpmounting, the sensing volume is positioned only millimetres from the scalp surface and the measured magnetic field is consequently higher compared to superconducting sensors (which are located further away), providing increased sensitivity (Boto et al., 2017, 2016; Iivanainen et al., 2017).”
BackgroundQuantification of the benefit from integrating MEG and EEG data in minimum ℓ2-norm estimation
Molins, A., Stufflebeam, S. M., Brown, E. N., & Hämäläinen, M. S. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.064 · Cited by 192 · see citing works
Flagged first, then by citations
Research works printed but not linked: 35
- Allred JC, Lyman RN, Kornack TW, Romalis MV, 2002. High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation. Phys. Rev. Lett. 89, 130801. 10.1103/PhysRevLett.89.130801. 12225013 · DOI · Paper page
- Babiloni F, Babiloni C, Carducci F, Romani GL, Rossini PM, Angelone LM, Cincotti F, 2004. Multimodal integration of EEG and MEG data: a simulation study with variable signal-to-noise ratio and number of sensors. Hum. Brain Mapp. 10.1002/hbm.20011. PMC6872116 15083526 · DOI
- Babiloni F, Carducci F, Cincotti F, Del Gratta, C., Pizzella V, Romani GL, Rossini PM, Tecchio F, Babiloni C, 2001. Linear inverse source estimate of combined EEG and MEG data related to voluntary movements. Hum. Brain Mapp. 10.1002/hbm.1052. PMC6871788 11668651 · DOI
- Baillet S, 2017. Magnetoencephalography for brain electrophysiology and imaging. Nat. Neurosci. 20, 327– 339. 10.1038/nn.4504. 28230841 · DOI · Paper page
- Baillet S, Garnero L, Marin G, Hugonin JP, 1999. Combined MEG and EEG source imaging by minimization of mutual information. IEEE Trans. Biomed. Eng. 46, 522– 534. 10.1109/10.759053. 10230131 · DOI
- Borna A, Carter TR, Goldberg JD, Colombo AP, Jau YY, Berry C, McKay J, Stephen J, Weisend M, Schwindt PDD, 2017. A 20-channel magnetoencephalography system based on optically pumped magnetometers. Phys. Med. Biol. 62, 8909– 8923. 10.1088/1361-6560/aa93d1. 29035875 PMC5890515 · DOI
- Boto E, Bowtell R, Krüger P, Fromhold TM, Morris PG, Meyer SS, Barnes GR, Brookes MJ, 2016. On the potential of a new generation of magnetometers for MEG: a beamformer simulation study. PLoS One 11, e0157655. 10.1371/journal.pone.0157655. 27564416 PMC5001648 · DOI · Paper page
- Claus S, Velis D, Lopes da Silva FH, Viergever MA, Kalitzin S, 2012. High frequency spectral components after Secobarbital: the contribution of muscular origin-A study with MEG/EEG. Epilepsy Res. 100, 132– 141. 10.1016/j.eplepsyres.2012.02.002. 22476037 · DOI
- Cooper R, Winter AL, Crow HJ, Walter WG, 1965. Comparison of subcortical, cortical and scalp activity using chronically indwelling electrodes in man. Electroencephalogr. Clin. Neurophysiol. 10.1016/0013-4694(65)90088-X. 14255050 · DOI
- DeLucchi MR, Garoutte B, Aird RB, 1962. The scalp as an electroencephalographic averager. Electroencephalogr. Clin. Neurophysiol. 10.1016/0013-4694(62)90028-7. 13885270 · DOI
- Fuchs M, Wagner M, Wischmann HA, Köhler T, Theißen A, Drenckhahn R, Buchner H, 1998. Improving source reconstructions by combining bioelectric and biomagnetic data. Electroencephalogr. Clin. Neurophysiol. 107, 93– 111. 10.1016/S0013-4694(98)00046-7. 9751281 · DOI
- Goldenholz DM, Ahlfors SP, Hämäläinen MS, Sharon D, Ishitobi M, Vaina LM, Stufflebeam SM, 2009. Mapping the signal-to-noise-ratios of cortical sources in magnetoencephalography and electroencephalography. Hum. Brain Mapp. 10.1002/hbm.20571. PMC2882168 18465745 · DOI
- Hämäläinen M, Lundqvist D, 2019. MEG as an Enabling Tool in Neuroscience: Transcending Boundaries with New Analysis Methods and Devices. In: Supek S, Aine C (Eds.), Magnetoencephalography: From Signals to Dynamic Cortical Networks. Springer. 10.1007/978-3-319-62657-4_81-1. · DOI
- Holmes N, Leggett J, Boto E, Roberts G, Hill RM, Tierney TM, Shah V, Barnes GR, Brookes MJ, Bowtell R, 2018. Abi-planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography. Neuroimage 181, 760– 774. 10.1016/j.neuroimage.2018.07.028. 30031934 PMC6150951 · DOI · Paper page
- Hoogenboom N, Schoffelen JM, Oostenveld R, Parkes LM, Fries P, 2006. Localizing human visual gamma-band activity in frequency, time and space. Neuroimage 29 (3), 764– 773. 10.1016/j.neuroimage.2005.08.043. 16216533 · DOI
- Huang MX, Song T, Hagler DJ, Podgorny I, Jousmaki V, Cui L, Gaa K, Harrington DL, Dale AM, Lee RR, Elman J, Halgren E, 2007. A novel integrated MEG and EEG analysis method for dipolar sources. Neuroimage 10.1016/j.neuroimage.2007.06.002. PMC2819417 17658272 · DOI
- Iivanainen J, Zetter R, Grön M, Hakkarainen K, Parkkonen L, 2019a. On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers. Neuroimage 194, 244– 258. 10.1016/j.neuroimage.2019.03.022. 30885786 PMC6536327 · DOI · Paper page
- Iivanainen J, Zetter R, Parkkonen L, 2019b. In: Potential of On-Scalp MEG: Robust Detection of Human Visual Gamma-Band Responses bioRxiv 602342. 10.1101/602342. PMC7267937 31571310 · DOI
- Jiménez-Martínez R, Knappe S, 2017. Microfabricated optically-pumped magnetometers. In: Grosz A, Haji-Sheikh MJ, Mukhopadhyay SC (Eds.), Smart Sensors, Measurement and Instrumentation. Springer, Cham, pp. 523– 551. 10.1007/978-3-319-34070-8_17. · DOI
- Kamada K, Sato D, Ito Y, Natsukawa H, Okano K, Mizutani N, Kobayashi T, 2015. Human magnetoencephalogram measurements using newly developed compact module of high-sensitivity atomic magnetometer. Jpn. J. Appl. Phys. 54, 026601. 10.7567/JJAP.54.026601. · DOI
- Kim K, Begus S, Xia H, Lee SK, Jazbinsek V, Trontelj Z, Romalis MV, 2014. Multi-channel atomic magnetometer for magnetoencephalography: a configuration study. Neuroimage 89, 143– 151. 10.1016/j.neuroimage.2013.10.040. 24185014 · DOI
- Knappe S, Alem O, Sheng D, Kitching J, 2016. Microfabricated optically-pumped magnetometers for biomagnetic applications. J. Phys. Conf. Ser. 723, 012055. 10.1088/1742-6596/723/1/012055. · DOI
- Liu AK, Dale AM, Belliveau JW, 2002. Monte Carlo simulation studies of EEG and MEG localization accuracy. Hum. Brain Mapp. 10.1002/hbm.10024. PMC6871820 11870926 · DOI
- Mullinger KJ, Mayhew SD, Bagshaw AP, Bowtell R, Francis ST, 2013. Poststimulus undershoots in cerebral blood flow and BOLD fMRI responses are modulated by poststimulus neuronal activity. Proc. Natl. Acad. Sci. 110, 13636– 13641. 10.1073/pnas.1221287110. 23898206 PMC3746922 · DOI
- Muthukumaraswamy SD, 2013. High-frequency brain activity and muscle artifacts in MEG/EEG: a review and recommendations. Front. Hum. Neurosci. 7, 138. 10.3389/fnhum.2013.00138. 23596409 PMC3625857 · DOI · Paper page
- Osborne J, Orton J, Alem O, Shah V, 2018. Fully integrated, standalone zero field optically pumped magnetometer for biomagnetism. Proc. SPIE, Steep Dispers. Eng. Opto-Atomic Precis. Metrol. XI, 10548 10.1117/12.2299197. · DOI
- Pfurtscheller G, Lopes Da Silva FH, 1999. Event-related EEG/MEG synchronization and desynchronization: basic principles. Clin. Neurophysiol. 110, 1842– 1857. 10.1016/S1388-2457(99)00141-8. 10576479 · DOI · Paper page
- Sander TH, Preusser J, Mhaskar R, Kitching J, Trahms L, Knappe S, 2012. Magnetoencephalography with a chip-scale atomic magnetometer. Biomed. Opt. Express 3, 981. 10.1364/BOE.3.000981. 22567591 PMC3342203 · DOI
- Sarvas J, 1987. Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem. Phys. Med. Biol. 32, 11– 22. 10.1088/0031-9155/32/1/004. 3823129 · DOI
- Shah V, Knappe S, Schwindt PDD, Kitching J, 2007. Subpicotesla atomic magnetometry with a microfabricated vapour cell. Nat. Photonics 1, 649– 652. 10.1038/nphoton.2007.201. · DOI
- Sharon D, Hämäläinen MS, Tootell RBH, Halgren E, Belliveau JW, 2007. The advantage of combining MEG and EEG: comparison to fMRI in focally stimulated visual cortex. Neuroimage 10.1016/j.neuroimage.2007.03.066. PMC2706118 17532230 · DOI
- Sheng D, Perry AR, Krzyzewski SP, Geller S, Kitching J, Knappe S, 2017. A microfabricated optically-pumped magnetic gradiometer. Appl. Phys. Lett. 110. 10.1063/1.4974349. PMC5250637 28179732 · DOI · Paper page
- Tierney TM, Holmes N, Meyer SS, Boto E, Roberts G, Leggett J, Buck S, Duque-Muñoz L, Litvak V, Bestmann S, Baldeweg T, Bowtell R, Brookes MJ, Barnes GR, 2018. Cognitive neuroscience using wearable magnetometer arrays: non-invasive assessment of language function. Neuroimage 181, 513– 520. 10.1016/j.neuroimage.2018.07.035. 30016678 PMC6150946 · DOI
- Zhang Z, 1995. A fast method to compute surface potentials generated by dipoles within multilayer anisotropic spheres. Phys. Med. Biol. 40, 335– 349. 10.1088/0031-9155/40/3/001. 7732066 · DOI
- Zimmermann R, Scharein E, 2004. MEG and EEG show different sensitivity to myogenic artifacts. Neurol. Clin. Neurophysiol. NCN 78, 2004. 16012638
Cited by
Sorted by citations
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285 · see citing works
Self-citationA tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180 · see citing works
Self-citationCan EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142 · see citing works
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89 · see citing works
Self-citationWearable OPM-MEG: a changing landscape for epilepsy
Pedersen, M., Abbott, D. F., & Jackson, G. D. (2022) · Epilepsia · doi:10.1111/epi.17368 · Cited by 68 · see citing works
Naturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52 · see citing works
“, the difference between playing the game and resting) we also expected that, following each strike of the ball, a small amplitude increase in beta power should occur [17]; ssuming consistent timings, we exp cted this ffect should alternate between participants (e.”
BackgroundInfluentialSelf-citationNugent, A. C., Benitez Andonegui, A., Holroyd, T., & Robinson, S. E. (2022) · Neuroimage: Reports · doi:10.1016/j.ynirp.2022.100093 · Cited by 41 · see citing works
- Authors
- Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Boto, Elena
- ORCID
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 201
- Pages
- 116099
- ISSN
- 1053-8119 (ISSN-L)
- PMC
- PMC8235152
- OpenAlex
- W2967267902
- Cited by
- 136
- References
- 7
- Citations by year
- 2026: 13 · 2025: 25 · 2024: 21 · 2023: 18 · 2022: 23 · 2021: 22 · 2020: 11 · 2019: 2
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by-nc-nd)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/M013294/1)
- Medical Research Council (EP/L016052/1)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- wearable neuroimaging, magnetoencephalography, EEG, optically pumped magnetometers, spatial specificity
- MeSH terms
- Wearable Electronic Devices, Adult, Electroencephalography, Equipment Design, Female, Humans, Male, Magnetoencephalography, Neuroimaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review