A microfabricated optically-pumped magnetic gradiometer
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
We report on the development of a microfabricated atomic magnetic gradiometer based on optical spectroscopy of alkali atoms in the vapor phase. The gradiometer, which operates in the spin-exchange relaxation free regime, has a length of 60 mm and cross sectional diameter of 12 mm, and consists of two chip-scale atomic magnetometers which are interrogated by a common laser light. The sensor can measure differences in magnetic fields, over a 20 mm baseline, of 10 fT/[Formula: see text] at frequencies above 20 Hz. The maximum rejection of magnetic field noise is 1000 at 10 Hz. By use of a set of compensation coils wrapped around the sensor, we also measure the sensor sensitivity at several external bias field strengths up to 150 mG. This device is useful for applications that require both sensitive gradient field information and high common-mode noise cancellation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Bloch Equations with Diffusion Terms
Torrey, H. C. (1956) · Physical Review · doi:10.1103/physrev.104.563 · Cited by 1,216
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
A robust scanning diamond sensor for nanoscale imaging with single nitrogen-vacancy centres
Maletinsky, P., Hong, S., Grinolds, M. S., Hausmann, B., Lukin, M. D., Walsworth, R. L., Loncar, M., & Yacoby, A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.50 · Cited by 726
Chip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481
Self-citationSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Self-citationSpin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Research works printed but not linked: 2
- 2013, Optical Magnetometry
- S. J. Seltzer, Ph.D. thesis, Princeton University (2008).
Cited by
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
“…C. Johnson, Schwindt and Weisend, 2010; Kim et al., 2014; Labyt et al., 2018; Osborne et al., 2018; Sander et al., 2012a; Shah and Wakai, 2013; J. Sheng et al., 2017b; Xia et al., 2006), somatosensory evoked responses (Borna et al., 2017a; Boto et al., 2016b; C. Johnson et al., 2010; Kamada et…”
BackgroundMethodUltrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba8792 · Cited by 222
Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system
Brookes, M. J., Boto, E., Rea, M., Shah, V., Osborne, J., Holmes, N., Hill, R. M., Leggett, J., Rhodes, N., & Bowtell, R. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118025 · Cited by 151
Metadata
- Authors
- Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2017-01-16
- Volume
- 110
- Issue
- 3
- Pages
- 031106-031106
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- PMC
- PMC5250637
- OpenAlex
- W2572181495
- Cited by
- 179
- References
- 27
- Citations by year
- 2026: 13 · 2025: 26 · 2024: 15 · 2023: 30 · 2022: 25 · 2021: 25 · 2020: 17 · 2019: 23 · 2018: 2 · 2017: 3
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Applied Physics Letters (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Institutes of Health (1R01EB019440,1R44NS090894,R01NS094604)
- National Institute of Standards and Technology (Embedded Standards/NIST on a Chip initiative (EBS14))
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- magnetic gradiometer, atomic magnetometer, microfabrication, spin-exchange relaxation-free, alkali metal vapors, optical pumping, chip-scale sensors, magnetic field gradient measurement, common-mode noise suppression, compensation coils, intensity inhomogeneity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfabricated optically-pumped magnetic gradiometer. https://app.cochat.ai/papers/10.1063/1.4974349
- The paper
- Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017). A microfabricated optically-pumped magnetic gradiometer. Applied Physics Letters. https://doi.org/10.1063/1.4974349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.