Accurate and robust whole-head segmentation from magnetic resonance images for individualized head modeling
Open accessThe DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Transcranial brain stimulation (TBS) has been established as a method for modulating and mapping the function of the human brain, and as a potential treatment tool in several brain disorders. Typically, the stimulation is applied using a one-size-fits-all approach with predetermined locations for the electrodes, in electric stimulation (TES), or the coil, in magnetic stimulation (TMS), which disregards anatomical variability between individuals. However, the induced electric field distribution in the head largely depends on anatomical features implying the need for individually tailored stimulation protocols for focal dosing. This requires detailed models of the individual head anatomy, combined with electric field simulations, to find an optimal stimulation protocol for a given cortical target. Considering the anatomical and functional complexity of different brain disorders and pathologies, it is crucial to account for the anatomical variability in order to translate TBS from a research tool into a viable option for treatment. In this article we present a new method, called CHARM, for automated segmentation of fifteen different head tissues from magnetic resonance (MR) scans. The new method compares favorably to two freely available software tools on a five-tissue segmentation task, while obtaining reasonable segmentation accuracy over all fifteen tissues. The method automatically adapts to variability in the input scans and can thus be directly applied to clinical or research scans acquired with different scanners, sequences or settings. We show that an increase in automated segmentation accuracy results in a lower relative error in electric field simulations when compared to anatomical head models constructed from reference segmentations. However, also the improved segmentations and, by implication, the electric field simulations are affected by systematic artifacts in the input MR scans. As long as the artifacts are unaccounted for, this can lead to local simulation differences up to 30% of the peak field strength on reference simulations. Finally, we exemplarily demonstrate the effect of including all fifteen tissue classes in the field simulations against the standard approach of using only five tissue classes and show that for specific stimulation configurations the local differences can reach 10% of the peak field strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 1×
“…open-source toolboxes for simulation of TBS (Huang et al., 2019; Thielscher et al., 2015) and source mapping in MEG and EEG (Gramfort et al., 2013; Oostenveld et al., 2011; Tadel et al., 2011) include automated generation of individualized volume conductor models directly from structural magnetic…”
MethodFischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656 · cited 2×
“We illustrate how segmentation differences between HEADRECO and CHARM result in clear differences in the estimated e-fields in a standard M1-SO TDCS stimulation paradigm (Nitsche and Paulus, 2000), where we placed rectangular electrodes of size 5 7 cm over the C3 (anode) and AF4 (cathode), see Figs.”
MethodMEG and EEG data analysis with MNE-Python
Gramfort, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00267 · Cited by 3,784
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677 · cited 1×
“…simulation of TBS (Huang et al., 2019; Thielscher et al., 2015) and source mapping in MEG and EEG (Gramfort et al., 2013; Oostenveld et al., 2011; Tadel et al., 2011) include automated generation of individualized volume conductor models directly from structural magnetic resonance (MR) scans of…”
MethodA modified Hausdorff distance for object matching
Dubuisson, M.-P., & Jain, A. K. (2002) · Proceedings of 12th International Conference on Pattern Recognition · doi:10.1109/icpr.1994.576361 · Cited by 1,464 · cited 1×
“…maximum of two directed Hausdorff distances, h m ð A ; M Þ and h m ð M ; A Þ : H ð A ; M Þ¼ max f h m ð A ; M Þ ; h m ð M ; A Þg ; where the directed Hausdorff distance is de fi ned as: which measures the average distance between the closest points in the two point sets (Dubuisson and Jain, 1994).”
BackgroundIglesias, J. E., Augustinack, J. C., Nguyen, K., Player, C. M., Player, A., Wright, M., Roy, N., Frosch, M. P., McKee, A. C., Wald, L. L., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.042 · Cited by 1,277
Self-citationAdaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Cited by
SynthSeg: Segmentation of brain MRI scans of any contrast and resolution without retraining
Billot, B., Greve, D. N., Puonti, O., Thielscher, A., Van Leemput, K., Fischl, B., Dalca, A. V., & Iglesias, J. E. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102789 · Cited by 641
Self-citationVan Hoornweder, S., Nuyts, M., Frieske, J., Verstraelen, S., Meesen, R. L. J., & Caulfield, K. A. (2023) · doi:10.1101/2023.02.22.529540 · Cited by 37
Metadata
- Authors
- Puonti, O., Van Leemput, K., Saturnino, G. B., Siebner, H. R., Madsen, K. H., & Thielscher, A.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 219
- Pages
- 117044
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W3034190502
- Cited by
- 235
- References
- 64
- FWCI
- 5.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate and robust whole-head segmentation from magnetic resonance images for individualized head modeling. https://app.cochat.ai/papers/10.1016/j.neuroimage.2020.117044
- The paper
- Puonti, O., Van Leemput, K., Saturnino, G. B., Siebner, H. R., Madsen, K. H., & Thielscher, A. (2020). Accurate and robust whole-head segmentation from magnetic resonance images for individualized head modeling. NeuroImage. https://doi.org/10.1016/j.neuroimage.2020.117044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.