CoChat

Partial volume correction analysis for 11C-UCB-J PET studies of Alzheimer's disease

Open access
Lu, Yihuan, Toyonaga, Takuya, Naganawa, Mika, Gallezot, Jean-Dominique, Chen, Ming-Kai, Mecca, Adam P., van Dyck, Christopher H., Carson, Richard E. · 2021 · NeuroImage
Cited by 37

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

11C-UCB-J PET imaging, targeting synaptic vesicle glycoprotein 2A (SV2A), has been shown to be a useful indicator of synaptic density in Alzheimer's disease (AD). For SV2A imaging, a decrease in apparent tracer uptake is often due to the combination of gray-matter (GM) atrophy and SV2A decrease in the remaining tissue. Our aim is to reveal the true SV2A change by performing partial volume correction (PVC). We performed two PVC algorithms, Müller-Gärtner (MG) and ‘iterative Yang’ (IY), on 17 AD participants and 11 cognitive normal (CN) participants using the brain-dedicated HRRT scanner. Distribution volume VT, the rate constant K1, binding potential BPND (centrum semiovale as reference region), and tissue volume were compared. In most regions, both PVC algorithms reduced the between-group differences. Alternatively, in hippocampus, IY increased the significance of between-group differences while MG reduced it (VT, BPND and K1 group differences: uncorrected: 20%, 27%, 17%; MG: 18%, 22%, 14%; IY: 22%, 28%, 17%). The group difference in hippocampal volume (10%) was substantially smaller than any PET measures. MG increased GM binding values to a greater extent than IY due to differences in algorithm assumptions. 11C-UCB-J binding is significantly reduced in AD hippocampus, but PVC is important to adjust for significant volume reduction. After correction, PET measures are substantially more sensitive to group differences than volumetric MRI measures. Assumptions of each PVC algorithm are important and should be carefully examined and validated. For 11C-UCB-J, the less stringent assumptions of IY support its use as a PVC algorithm over MG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2021.118248

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 37

Metadata

Authors
Lu, Y., Toyonaga, T., Naganawa, M., Gallezot, J.-D., Chen, M.-K., Mecca, A. P., van Dyck, C. H., & Carson, R. E.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2021-09
Volume
238
Pages
118248
ISSN
1053-8119 (ISSN-L)
OpenAlex
W3171384009
Cited by
37
References
8
FWCI
3.81
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Partial volume correction analysis for 11C-UCB-J PET studies of Alzheimer's disease. https://app.cochat.ai/papers/10.1016/j.neuroimage.2021.118248
The paper
Lu, Y., Toyonaga, T., Naganawa, M., Gallezot, J.-D., Chen, M.-K., Mecca, A. P., van Dyck, C. H., & Carson, R. E. (2021). Partial volume correction analysis for 11C-UCB-J PET studies of Alzheimer's disease. NeuroImage. https://doi.org/10.1016/j.neuroimage.2021.118248

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.