Transcutaneous electrical nerve stimulation at both high and low frequencies activates ventrolateral periaqueductal grey to decrease mechanical hyperalgesia in arthritic rats
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Transcutaneous electric nerve stimulation (TENS) is widely used for the treatment of pain. TENS produces an opioid-mediated antinociception that utilizes the rostroventromedial medulla (RVM). Similarly, antinociception evoked from the periaqueductal grey (PAG) is opioid-mediated and includes a relay in the RVM. Therefore, we investigated whether the ventrolateral or dorsolateral PAG mediates antinociception produced by TENS in rats. Paw and knee joint mechanical withdrawal thresholds were assessed before and after knee joint inflammation (3% kaolin/carrageenan), and after TENS stimulation (active or sham). Cobalt chloride (CoCl2; 5 mM) or vehicle was microinjected into the ventrolateral periaqueductal grey (vlPAG) or dorsolateral periaqueductal grey (dlPAG) prior to treatment with TENS. Either high (100 Hz) or low (4 Hz) frequency TENS was then applied to the inflamed knee for 20 min. Active TENS significantly increased withdrawal thresholds of the paw and knee joint in the group microinjected with vehicle when compared to thresholds prior to TENS (P<0.001) or to sham TENS (P<0.001). The increases in withdrawal thresholds normally observed after TENS were prevented by microinjection of CoCl2 into the vlPAG, but not the dlPAG prior to TENS and were significantly lower than controls treated with TENS (P<0.001). In a separate group of animals, microinjection of CoCl2 into the vlPAG temporarily reversed the decreased mechanical withdrawal threshold suggesting a role for the vlPAG in the facilitation of joint pain. No significant difference was observed for dlPAG. We hypothesize that the effects of TENS are mediated through the vlPAG that sends projections through the RVM to the spinal cord to produce an opioid-mediated analgesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963 · cited 2×
“Schematic coronal sections of the rat brain adapted from Paxinos and Watson (2005) illustrating approximate sites of microinjections into the vlPAG (A) and dlPAG (B).”
InfluentialThe rat brain in stereotaxic coordinates
Palkovits, M. (1983) · Neuropeptides · doi:10.1016/0143-4179(83)90049-5 · Cited by 28,831
Endogenous Pain Control Systems: Brainstem Spinal Pathways and Endorphin Circuitry
Basbaum, A. I., & Fields, H. L. (1984) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.07.030184.001521 · Cited by 2,687 · cited 1×
“The PAG does not have a major projection to the spinal cord (Basbaum and Fields, 1984), but produces its effects through a relay in the RVM, i.e. the nucleus raphe magnus (NRM) and adjacent structures (Kuypers and Maisky, 1975; Castiglioni et al., 1978; Mantyh and Peschanski, 1982; Urban and Smith,…”
Hagiwara, S., & Byerly, L. (1981) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.04.030181.000441 · Cited by 1,192
Neurotransmitters in Nociceptive Modulatory Circuits
Fields, H. L., Heinricher, M. M., & Mason, P. (1991) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.14.030191.001251 · Cited by 993 · cited 2×
“…IH -PA Author M anuscript The midbrain periaqueductal grey (PAG) surrounds the midbrain aqueduct (Osborne et al., 1996) and is implicated in a wide variety of functions including opioid-mediated analgesia (Gebhart et al., 1988; Fields et al., 1991; Osborne et al., 1996; Vaughan and Christie, 1997).”
Functional characteristics of the midbrain periaqueductal gray.
Behbehani, M. M. (1995) · Progress in Neurobiology · doi:10.1016/0301-0082(95)00009-k · Cited by 879 · cited 2×
“Numerous studies show that morphine microinjection into the ventral PAG produces analgesia (Jacquet and Lajtha, 1976; Yaksh et al., 1976; Lewis and Gebhart, 1977; Jensen and Yaksh, 1986; Siuciak and Advokat, 1987; Behbehani, 1995).”
Hosobuchi, Y., Adams, J. E., & Linchitz, R. (1977) · Science · doi:10.1126/science.301658 · Cited by 757 · cited 2×
“Opioid administration into the vlPAG in the rat (Jensen and Yaksh, 1989; Krzanowska and Bodnar, 1999; Tershner et al., 2000) and cat (Oliveras et al., 1974), as well as electrical stimulation of the PAG in humans (Hosobuchi et al., 1977) produces antinociception.”
Yaksh, T. L., Yeung, J. C., & Rudy, T. A. (1976) · Brain Research · doi:10.1016/0006-8993(76)91009-x · Cited by 610 · cited 2×
“Numerous studies show that morphine microinjection into the ventral PAG produces analgesia (Jacquet and Lajtha, 1976; Yaksh et al., 1976; Lewis and Gebhart, 1977; Jensen and Yaksh, 1986; Siuciak and Advokat, 1987; Behbehani, 1995).”
Kuypers, H. G. J. M., & Maisky, V. A. (1975) · Neuroscience Letters · doi:10.1016/0304-3940(75)90004-x · Cited by 607 · cited 1×
“…does not have a major projection to the spinal cord (Basbaum and Fields, 1984), but produces its effects through a relay in the RVM, i.e. the nucleus raphe magnus (NRM) and adjacent structures (Kuypers and Maisky, 1975; Castiglioni et al., 1978; Mantyh and Peschanski, 1982; Urban and Smith, 1994).”
Han, J. S., Chen, X. H., Sun, S. L., Xu, X. J., Yuan, Y., Yan, S. C., Hao, J. X., & Terenius, L. (1991) · Pain · doi:10.1016/0304-3959(91)90218-m · Cited by 448 · cited 1×
“Further high frequency TENS increases the concentration of β-endorphins increase in the bloodstream and cerebrospinal fluid, and methionine– enkephalin in the cerebrospinal fluid, in human subjects (Han et al., 1991; Salar et al., 1981).”
Cited by
Using Tens for Pain Control: The State of the Evidence
Vance, C. G., Dailey, D. L., Rakel, B. A., & Sluka, K. A. (2014) · Pain Management · doi:10.2217/pmt.14.13 · Cited by 480
Self-citationA Mechanism-Based Approach to Physical Therapist Management of Pain
Chimenti, R. L., Frey-Law, L. A., & Sluka, K. A. (2018) · Physical Therapy · doi:10.1093/ptj/pzy030 · Cited by 300
Self-citationTranscutaneous electrical nerve stimulation (TENS) for neuropathic pain in adults
Gibson, W., Wand, B. M., & O'Connell, N. E. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011976.pub2 · Cited by 247
Dailey, D. L., Rakel, B. A., Vance, C. G. T., Liebano, R. E., Amrit, A. S., Bush, H. M., Lee, K. S., Lee, J. E., & Sluka, K. A. (2013) · Pain · doi:10.1016/j.pain.2013.07.043 · Cited by 241
“TENS activates central inhibitory pathways [8,23,37,52] and decreases central excitability [23,34,36,53,55].”
Self-citationSluka, K. A., Bjordal, J. M., Marchand, S., & Rakel, B. A. (2013) · Physical Therapy · doi:10.2522/ptj.20120281 · Cited by 204
Self-citationAdvances and challenges in neurostimulation for headaches
Magis, D., & Schoenen, J. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70139-4 · Cited by 196
Nijs, J., Meeus, M., Van Oosterwijck, J., Ickmans, K., Moorkens, G., Hans, G., & De Clerck, L. S. (2012) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2011.02575.x · Cited by 192
Vance, C. G. T., Rakel, B. A., Blodgett, N. P., DeSantana, J. M., Amendola, A., Zimmerman, M. B., Walsh, D. M., & Sluka, K. A. (2012) · Physical Therapy · doi:10.2522/ptj.20110183 · Cited by 178
Self-citationNoninvasive vagus nerve stimulation as treatment for trigeminal allodynia
Oshinsky, M. L., Murphy, A. L., Hekierski, H., Cooper, M., & Simon, B. J. (2014) · Pain · doi:10.1016/j.pain.2014.02.009 · Cited by 165
“electrical nerve stimulators (ONS and TENS, respectively) work via an increase in GABA in the dorsal horn of the spinal cord [3,4,11,14,15,24,26].”
Schabrun, S. M., Jones, E., Elgueta Cancino, E. L., & Hodges, P. W. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.01.058 · Cited by 159
“PES targets mechanisms of sensitization such as activation of descending antinociceptive pathways [11,12], activation of inhibitory neural circuits in the spinal cord [13], enhanced opioid and inhibitory neurotransmitter receptor activity [14,15] and consequently, spinal upregulation of inhibitory neurotransmitter rel…”
Rakel, B. A., Zimmerman, B. M., Geasland, K., Embree, J., Clark, C. R., Noiseux, N. O., Callaghan, J. J., Herr, K., Walsh, D., & Sluka, K. A. (2014) · Pain · doi:10.1016/j.pain.2014.09.025 · Cited by 115
“TENS activates endogenous inhibitory mechanisms including opioid receptors in the spinal cord and brainstem [22,41,65], reduces central neuron sensitization [47], and reduces primary and secondary mechanical hyperalgesia (ie, pain sensitivity to force or pressure) induced by knee joint inflammation [56,61,64,72].”
Self-citationSong, H., Kim, M., Kim, E., Lee, J., Jeong, I., Lim, K., Ryu, S. Y., Oh, M., Kim, Y., & Park, J. (2024) · BMEMat · doi:10.1002/bmm2.12048 · Cited by 61
Metadata
- Authors
- DeSantana, J. M., Da Silva, L. F. S., De Resende, M. A., & Sluka, K. A.
- Venue
- Neuroscience
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 163
- Issue
- 4
- Pages
- 1233-1241
- ISSN
- 0306-4522 (ISSN-L)
- OpenAlex
- W2039660679
- Cited by
- 159
- References
- 74
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.