CoChat

Brain and cord myelin water imaging: a progressive multiple sclerosis biomarker

Open access
Kolind, Shannon, Seddigh, Arshia, Combes, Anna, Russell-Schulz, Bretta, Tam, Roger, Yogendrakumar, Vignan, Deoni, Sean, Sibtain, Naomi A., Traboulsee, Anthony, Williams, Steven C.R., Barker, Gareth J., Brex, Peter A. · 2015 · NeuroImage: Clinical
Cited by 54

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Conventional magnetic resonance imaging (MRI) is used to diagnose and monitor inflammatory disease in relapsing remitting (RR) multiple sclerosis (MS). In the less common primary progressive (PP) form of MS, in which focal inflammation is less evident, biomarkers are still needed to enable evaluation of novel therapies in clinical trials. Our objective was to characterize the association - across the brain and cervical spinal cord - between clinical disability measures in PPMS and two potential biomarkers (one for myelin, and one for atrophy, both resulting from the same imaging technique). METHODS: Multi-component driven equilibrium single pulse observation of T1 and T2 (mcDESPOT) MRI of the brain and cervical spinal cord were obtained for 15 PPMS patients and 11 matched controls. Data were analysed to estimate the signal related to myelin water (VFM), as well as volume measurements. MS disability was assessed using the Multiple Sclerosis Functional Composite score, which includes measures of cognitive processing (Paced Auditory Serial Addition Test), manual dexterity (9-Hole Peg Test) and ambulatory function (Timed 25-Foot Walk); and the Expanded Disability Status Scale. RESULTS: Brain and spinal cord volumes were different in PPMS compared to controls, particularly ventricular (+ 46%, p = 0.0006) and cervical spinal cord volume (- 16%, p = 0.0001). Brain and spinal cord myelin (VFM) were also reduced in PPMS (brain: - 11%, p = 0.01; spine: - 19%, p = 0.000004). Cognitive processing correlated with brain ventricular volume (p = 0.009). Manual dexterity correlated with brain ventricular volume (p = 0.007), and both brain and spinal cord VFM (p = 0.01 and 0.06, respectively). Ambulation correlated with spinal cord volume (p = 0.04) and spinal cord VFM (p = 0.04). INTERPRETATION: In this study we demonstrated that mcDESPOT can be used to measure myelin and atrophy in the brain and spinal cord. Results correlate well with clinical disability scores in PPMS representing cognitive, fine motor and ambulatory disability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nicl.2015.10.002

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 54

Metadata

Authors
Kolind, S., Seddigh, A., Combes, A., Russell-Schulz, B., Tam, R., Yogendrakumar, V., Deoni, S., Sibtain, N. A., Traboulsee, A., Williams, S. C. R., Barker, G. J., & Brex, P. A.
Venue
NeuroImage: Clinical
Publisher
Elsevier BV
Published
2015
Volume
9
Pages
574-580
ISSN
2213-1582 (ISSN-L)
OpenAlex
W1857647137
Cited by
54
References
7
FWCI
4.13
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Brain and cord myelin water imaging: a progressive multiple sclerosis biomarker. https://app.cochat.ai/papers/10.1016/j.nicl.2015.10.002
The paper
Kolind, S., Seddigh, A., Combes, A., Russell-Schulz, B., Tam, R., Yogendrakumar, V., Deoni, S., Sibtain, N. A., Traboulsee, A., Williams, S. C. R., Barker, G. J., & Brex, P. A. (2015). Brain and cord myelin water imaging: a progressive multiple sclerosis biomarker. NeuroImage: Clinical. https://doi.org/10.1016/j.nicl.2015.10.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.