The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Modifying a sealed tube zinc reduction method for preparation of AMS graphite targets: Reducing background and attaining high precision
Open accessAbstract
The sealed tube zinc reduction method for converting CO2 to graphite for AMS 14C measurements was originally developed for rapid production of graphite in biomedical tracer experiments. The method was usually thought to have low precision and a high background. We have modified the zinc reduction method originally outlined in Vogel [J.S. Vogel, Radiocarbon 34 (3) (1992) 344] by carefully controlling the amounts of reagents (zinc, titanium hydride and Co or Fe catalyst) and now routinely obtain a precision of 2–3‰ and a relatively low background of ∼50,000 14C years when analyzing for 14C at the Keck Carbon Cycle AMS facility at UC Irvine. Fractionation of carbon isotopes does occur during graphitization and depends on the graphitization yield, which can be affected by the amounts of reagents used and other conditions. The δ13C of our zinc-reduced graphite is usually lighter by 2–3‰ than the CO2 from which it is made, but this is corrected for in our system by simultaneous measurement of 13C/12C along with 14C/12C by the spectrometer. This method is suitable for 14C enriched samples, as well as natural abundance 14C samples, especially those with modern 14C contents. With improved precision and background, we believe that many disciplines can benefit from this technique because of its low cost and rapid production of graphite.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance of catalytically condensed carbon for use in accelerator mass spectrometry
Vogel, J. S., Southon, J. R., Nelson, D. E., & Brown, T. A. (1984) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(84)90529-9 · Cited by 695
Self-citationBottinga, Y. (1969) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(69)90092-1 · Cited by 679
Gaudinski, J. B., Trumbore, S. E., Davidson, E. A., & Zheng, S. (2000) · Biogeochemistry · doi:10.1023/a:1006301010014 · Cited by 620
Self-citationThe Tropospheric 14CO2 Level in Mid-Latitudes of the Northern Hemisphere (1959–2003)
Levin, I., & Kromer, B. (2004) · Radiocarbon · doi:10.1017/s0033822200033130 · Cited by 533
Preparation of Small Samples for 14C Accelerator Targets by Catalytic Reduction of CO
Slota, P. J., Jull, A. J. T., Linick, T. W., & Toolin, L. J. (1987) · Radiocarbon · doi:10.1017/s0033822200056988 · Cited by 508
Progress in Radiocarbon Target Preparation at the Antares AMS Centre
Hua, Q., Jacobsen, G. E., Zoppi, U., Lawson, E. M., Williams, A. A., Smith, A. M., & McGann, M. J. (2001) · Radiocarbon · doi:10.1017/s003382220003811x · Cited by 311
14C Background Levels in An Accelerator Mass Spectrometry System
Vogel, J. S., Nelson, D. E., & Southon, J. R. (1987) · Radiocarbon · doi:10.1017/s0033822200043733 · Cited by 286
Self-citationA Batch Preparation Method for Graphite Targets With Low Background for AMS 14C Measurements
Kitagawa, H., Masuzawa, T., Makamura, T., & Matsumoto, E. (1993) · Radiocarbon · doi:10.1017/s0033822200064973 · Cited by 260
Ultra small-mass AMS 14C sample preparation and analyses at KCCAMS/UCI Facility
Santos, G. M., Southon, J. R., Griffin, S., Beaupre, S. R., & Druffel, E. R. M. (2007) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2007.01.172 · Cited by 255
Self-citationRapid Production of Graphite Without Contamination for Biomedical AMS
Vogel, J. S. (1992) · Radiocarbon · doi:10.1017/s0033822200063529 · Cited by 240
Comparison of Fractionation Methods for Soil Organic Matter 14C Analysis
Trumbore, S. E., & Zheng, S. (1996) · Radiocarbon · doi:10.1017/s0033822200017598 · Cited by 181
Self-citationMicroscale AMS 14C Measurement at NOSAMS
Pearson, A., Mcnichol, A. P., Schneider, R. J., Von Reden, K. F., & Zheng, Y. (1997) · Radiocarbon · doi:10.1017/s0033822200017902 · Cited by 171
Ognibene, T. J., Bench, G., Vogel, J. S., Peaslee, G. F., & Murov, S. (2003) · Analytical Chemistry · doi:10.1021/ac026334j · Cited by 161
Carbon isotope fractionation between graphite, diamond and carbon dioxide
Bottinga, Y. (1968) · Earth and Planetary Science Letters · doi:10.1016/s0012-821x(68)80056-1 · Cited by 143
Refinement of graphite target production at ORAU
Dee, M., & Ramsey, C. B. (2000) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(00)00337-2 · Cited by 115
Illumination of a Black Box: Analysis of Gas Composition During Graphite Target Preparation
McNichol, A. P., Gagnon, A. R., Jones, G. A., & Osborne, E. A. (1992) · Radiocarbon · doi:10.1017/s0033822200063499 · Cited by 101
Cisneros‐Dozal, L. M., Trumbore, S. E., & Hanson, P. J. (2005) · Global Change Biology · doi:10.1111/j.1365-2486.2005.001061.x · Cited by 100
Self-citationProduction of Graphite Targets by Deposition from CO/H2for Precision Accelerator14C Measurements
Jull, A. J. T., Donahue, D. J., Hatheway, A. L., Linick, T. W., & Toolin, L. J. (1986) · Radiocarbon · doi:10.1017/s0033822200007268 · Cited by 68
Variability of Monthly Radiocarbon During the 1760S in Corals from the Galapagos Islands
Druffel, E. R. M., Griffin, S., Hwang, J., Tomoko Komada, A., Beaupré, S. R., Druffel-Rodriguez, K. C., Santos, G. M., & Southon, J. R. (2004) · Radiocarbon · doi:10.1017/s0033822200035670 · Cited by 25
Self-citationVerkouteren, R. M., Klinedinst, D. B., & Currie, L. A. (1997) · Radiocarbon · doi:10.1017/s003382220005325x · Cited by 21
Contamination and Fractionation Effects in AMS-Measured 14C/12C and 13C/12C Ratios of Small Samples
Alderliesten, C., van der Borg, K., & de Jong, A. F. M. (1997) · Radiocarbon · doi:10.1017/s0033822200018075 · Cited by 17
Cited by
Seasonal dynamics and age of stemwood nonstructural carbohydrates in temperate forest trees
Richardson, A. D., Carbone, M. S., Keenan, T. F., Czimczik, C. I., Hollinger, D. Y., Murakami, P., Schaberg, P. G., & Xu, X. (2013) · New Phytologist · doi:10.1111/nph.12042 · Cited by 419
Self-citationKramer, C., Trumbore, S., Fröberg, M., Cisneros Dozal, L. M., Zhang, D., Xu, X., Santos, G. M., & Hanson, P. J. (2010) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2010.02.021 · Cited by 138
“The precision and accuracy for measurements of graphite targets by AMS are determined by measuring of known-age standards e for standards that are not small samples, these are 2e3& at the WM Keck Carbon Cycle AMS (Xu et al., 2007).”
MethodInfluentialSelf-citationMervine, E. M., Humphris, S. E., Sims, K. W. W., Kelemen, P. B., & Jenkins, W. J. (2014) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2013.11.007 · Cited by 88
Noronha, A. L., Johnson, K. R., Southon, J. R., Hu, C., Ruan, J., & McCabe-Glynn, S. (2015) · Quaternary Science Reviews · doi:10.1016/j.quascirev.2015.05.021 · Cited by 57
Self-citationNai, H., Zhong, J., Yi, Y., Lai, M., He, D., Dittmar, T., Liu, C.-Q., Li, S.-L., & Xu, S. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c01593 · Cited by 38
Metadata
- Authors
- Xu, X., Trumbore, S. E., Zheng, S., Southon, J. R., McDuffee, K. E., Luttgen, M., & Liu, J. C.
- Venue
- Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Publisher
- Elsevier BV
- Published
- 2007-06
- Volume
- 259
- Issue
- 1
- Pages
- 320-329
- ISSN
- 0168-583X (ISSN-L)
- OpenAlex
- W2046968287
- Cited by
- 428
- References
- 21
- FWCI
- 11.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.