The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A High-Throughput Method for the Conversion of CO2 Obtained from Biochemical Samples to Graphite in Septa-Sealed Vials for Quantification of 14C via Accelerator Mass Spectrometry
Abstract
The growth of accelerator mass spectrometry as a tool for quantitative isotope ratio analysis in the biosciences necessitates high-throughput sample preparation. A method has been developed to convert CO(2) obtained from carbonaceous samples to solid graphite for highly sensitive and precise (14)C quantification. Septa-sealed vials are used along with commercially available disposable materials, eliminating sample cross contamination, minimizing complex handling, and keeping per sample costs low. Samples containing between 0.25 and 10 mg of total carbon can be reduced to graphite in approximately 4 h in routine operation. Approximately 150 samples per 8-h day can be prepared by a single technician.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Discussion Reporting of 14 C Data
Stuiver, M., & Polach, H. A. (1977) · Radiocarbon · doi:10.1017/s0033822200003672 · Cited by 5,640
14C Background Levels in An Accelerator Mass Spectrometry System
Vogel, J. S., Nelson, D. E., & Southon, J. R. (1987) · Radiocarbon · doi:10.1017/s0033822200043733 · Cited by 286
Self-citationCorrections for contamination background in AMS 14C measurements
Brown, T. A., & Southon, J. R. (1997) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(96)00676-3 · Cited by 118
Cited by
Xu, X., Trumbore, S. E., Zheng, S., Southon, J. R., McDuffee, K. E., Luttgen, M., & Liu, J. C. (2007) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2007.01.175 · Cited by 428
Metadata
- Authors
- Ognibene, T. J., Bench, G., Vogel, J. S., Peaslee, G. F., & Murov, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-03
- Volume
- 75
- Issue
- 9
- Pages
- 2192-2196
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2034827986
- Cited by
- 161
- References
- 3
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A High-Throughput Method for the Conversion of CO2 Obtained from Biochemical Samples to Graphite in Septa-Sealed Vials for Quantification of 14C via Accelerator Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac026334j
- The paper
- Ognibene, T. J., Bench, G., Vogel, J. S., Peaslee, G. F., & Murov, S. (2003). A High-Throughput Method for the Conversion of CO2 Obtained from Biochemical Samples to Graphite in Septa-Sealed Vials for Quantification of 14C via Accelerator Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac026334j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.