Intraocular Pressure Fluctuation
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M. A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.701 · Cited by 3,705
Heijl, A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.10.1268 · Cited by 3,320
(2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00538-9 · Cited by 2,780
The effectiveness of intraocular pressure reduction in the treatment of normal-tension glaucoma
(1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00272-4 · Cited by 1,301
Lichter, P. (2001) · Ophthalmology · doi:10.1016/s0161-6420(01)00873-9 · Cited by 1,178
Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., & Lindenmuth, K. (2000) · Journal of Glaucoma · doi:10.1097/00061198-200004000-00002 · Cited by 901
Nouri-Mahdavi, K., Hoffman, D., Coleman, A. L., Liu, G., Li, G., Gaasterland, D., & Caprioli, J. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.02.017 · Cited by 704
Self-citationFluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial
Bengtsson, B., Leske, M. C., Hyman, L., & Heijl, A. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.07.060 · Cited by 454
Kotecha, A., Elsheikh, A., Roberts, C. R., Zhu, H., & Garway-Heath, D. F. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0557 · Cited by 423
(2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.031 · Cited by 351
Cited by
Risk Factors for Glaucoma Onset and Progression
Coleman, A. L., & Miglior, S. (2008) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.08.006 · Cited by 540
Self-citationPrimary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Wang, X., Jiang, C., Ko, T., Kong, X., Yu, X., Min, W., Shi, G., & Sun, X. (2015) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-015-3095-y · Cited by 350
Schmidl, D., Garhofer, G., & Schmetterer, L. (2011) · Experimental Eye Research · doi:10.1016/j.exer.2010.09.002 · Cited by 282
Rates of visual field progression in clinical glaucoma care
Heijl, A., Buchholz, P., Norrgren, G., & Bengtsson, B. (2013) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2012.02492.x · Cited by 224
“Also, the AGIS investigators found that IOP variation was less important and only significant in eyes with low IOP levels, when they limited their analysis to eyes that had only one intervention (Caprioli & Coleman 2008).”
BackgroundWhy Do People (Still) Go Blind from Glaucoma?
Susanna, R., De Moraes, C. G., Cioffi, G. A., & Ritch, R. (2015) · Translational Vision Science & Technology · doi:10.1167/tvst.4.2.1 · Cited by 198
An Evidence-Based Review of Prognostic Factors for Glaucomatous Visual Field Progression
Ernest, P. J., Schouten, J. S., Beckers, H. J., Hendrikse, F., Prins, M. H., & Webers, C. A. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.09.005 · Cited by 186
Fogagnolo, P., Orzalesi, N., Ferreras, A., & Rossetti, L. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2889 · Cited by 75
Metadata
- Authors
- Caprioli, J., & Coleman, A. L.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2008-07
- Volume
- 115
- Issue
- 7
- Pages
- 1123-1129.e3
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2072182991
- Cited by
- 505
- References
- 21
- FWCI
- 24.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.