Optical Coherence Tomography Measurements and Analysis Methods in Optical Coherence Tomography Studies of Diabetic Macular Edema
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Objective To evaluate optical coherence tomography (OCT) measurements and methods of analysis of OCT data in studies of diabetic macular edema (DME). Design Associations of pairs of OCT variables and results of three analysis methods using data from two studies of DME. Participants Two hundred sixty-three subjects from a study of modified Early Treatment of Diabetic Retinopathy Study (mETDRS) versus modified macular grid (MMG) photocoagulation for DME and 96 subjects from a study of diurnal variation of DME. Methods Correlations were calculated for pairs of OCT variables at baseline and for changes in the variables over time. Distribution of OCT measurement changes, predictive factors for OCT measurement changes, and treatment group outcomes were compared when three measures of change in macular thickness were analyzed: absolute change in retinal thickness, relative change in retinal thickness, and relative change in retinal thickening. Main Outcome Measures Concordance of results using different OCT variables and analysis methods. Results Center point thickness correlated highly with central subfield mean thickness (CSMT) at baseline (0.98–0.99). The distributions of changes in CSMT were approximately normally distributed for absolute change in retinal thickness and relative change in retinal thickness, but not for relative change in retinal thickening. The macular thinning in the mETDRS group was significantly greater than in the MMG group when absolute change in retinal thickness was used, but not when relative change in thickness and relative change in thickening were used. Relative change in macular thickening provides unstable data in eyes with mild degrees of baseline thickening, unlike the situation with absolute or relative change in retinal thickness. Conclusions Central subfield mean thickness is the preferred OCT measurement for the central macula because of its higher reproducibility and correlation with other measurements of the central macula. Total macular volume may be preferred when the central macula is less important. Absolute change in retinal thickness is the preferred analysis method in studies involving eyes with mild macular thickening. Relative change in thickening may be preferable when retinal thickening is more severe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravitreal triamcinolone for refractory diabetic macular edema
Martidis, A., Duker, J. S., Greenberg, P. B., Rogers, A. H., Puliafito, C. A., Reichel, E., & Baumal, C. (2002) · Ophthalmology · doi:10.1016/s0161-6420(02)00975-2 · Cited by 1,032
Quantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
Topography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
(2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.06.052 · Cited by 614
Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography
Chan, A. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.2.193 · Cited by 424
(2007) · Archives of Ophthalmology · doi:10.1001/archopht.125.4.469 · Cited by 274
Optical coherence tomography for evaluating diabetic macular edema before and after vitrectomy
Massin, P., Duguid, G., Erginay, A., Haouchine, B., & Gaudric, A. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01837-8 · Cited by 244
Errors in Retinal Thickness Measurements Obtained by Optical Coherence Tomography
SADDA, S., WU, Z., WALSH, A., RICHINE, L., DOUGALL, J., CORTEZ, R., & LABREE, L. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.10.005 · Cited by 242
Self-citationKang, S. W., Park, C. Y., & Ham, D.-I. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.09.016 · Cited by 237
Brown, J. C. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.3.330 · Cited by 212
Cited by
Diabetic Macular Edema: Pathophysiology and Novel Therapeutic Targets
Das, A., McGuire, P. G., & Rangasamy, S. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.03.024 · Cited by 545
Maheshwary, A. S., Oster, S. F., Yuson, R. M. S., Cheng, L., Mojana, F., & Freeman, W. R. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.01.039 · Cited by 338
Virgili, G., Menchini, F., Casazza, G., Hogg, R., Das, R. R., Wang, X., & Michelessi, M. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008081.pub3 · Cited by 265
Diabetic macular edema: Evidence-based management
Stewart, M., Browning, D., & Lee, C. (2018) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1240_18 · Cited by 237
“99) with the latter.[114,115] Total macular volume (TMV) correlates somewhat less well with CST (r = 0.”
BackgroundSelf-citationOptical Coherence Tomography May Be Used to Predict Visual Acuity in Patients with Macular Edema
Pelosini, L., Hull, C. C., Boyce, J. F., McHugh, D., Stanford, M. R., & Marshall, J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4493 · Cited by 208
Rotsos, T. (2008) · Clinical Ophthalmology · doi:10.2147/opth.s4033 · Cited by 205
“It has been shown to produce highly reproducible measurements and it is as effective at detecting macular edema as fl uorescein angiography, but is superior at demonstrating axial distribution of the fl uid (Hee et al 1998; Browning et al 2008).”
BackgroundRetinal Imaging Techniques for Diabetic Retinopathy Screening
Goh, J. K. H., Cheung, C. Y., Sim, S. S., Tan, P. C., Tan, G. S. W., & Wong, T. Y. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816629491 · Cited by 174
Abràmoff, M. D., Tobey, D., & Char, D. S. (2020) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2020.02.022 · Cited by 140
“For our example, many foundational studies for diabetic retinopathy treatment and management performed over the past 5 decades were available, so that the so-called ETDRS severity scale, as well as the DRCR’s center-involved macular edema scale, were available as robust surrogate outcomes.(31,32,41,42) It is obviously…”
BackgroundVaradarajan, A. V., Bavishi, P., Ruamviboonsuk, P., Chotcomwongse, P., Venugopalan, S., Narayanaswamy, A., Cuadros, J., Kanai, K., Bresnick, G., Tadarati, M., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13922-8 · Cited by 139
Foundational Considerations for Artificial Intelligence Using Ophthalmic Images
Abràmoff, M. D., Cunningham, B., Patel, B., Eydelman, M. B., Leng, T., Sakamoto, T., Blodi, B., Grenon, S. M., Wolf, R. M., Manrai, A. K., et al. (2022) · Ophthalmology · doi:10.1016/j.ophtha.2021.08.023 · Cited by 96
Artificial intelligence for early detection of diabetes mellitus complications via retinal imaging
Sobhi, N., Sadeghi-Bazargani, Y., Mirzaei, M., Abdollahi, M., Jafarizadeh, A., Pedrammehr, S., Alizadehsani, R., Tan, R.-S., Islam, S. M. S., & Acharya, U. R. (2025) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-025-01596-7 · Cited by 39
A New Approach to Staging Diabetic Eye Disease
Channa, R., Wolf, R. M., Simo, R., Brigell, M., Fort, P., Curcio, C., Lynch, S., Verbraak, F., Abramoff, M. D., Abramoff, M. D., et al. (2024) · Ophthalmology Science · doi:10.1016/j.xops.2023.100420 · Cited by 26
“As mentioned, DRN, an early component of DRD, 9 can precede any other manifestation of DRD, including any vascular manifestations, 11,15 and may also affect future ischemic and exudative (DME) forms of DRD.”
Influential
Metadata
- Authors
- Browning, D. J., Glassman, A. R., Aiello, L. P., Bressler, N. M., Bressler, S. B., Danis, R. P., Davis, M. D., Ferris, F. L., Huang, S. S., Kaiser, P. K., Kollman, C., Sadda, S., Scott, I. U., & Qin, H.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2008-08
- Volume
- 115
- Issue
- 8
- Pages
- 1366-1371.e1
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W1499779252
- Cited by
- 164
- References
- 18
- FWCI
- 12.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.