The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in Glaucoma
Open accessAbstract
Purpose To detect macular perfusion defects in glaucoma using projection-resolved optical coherence tomography (OCT) angiography. Design Prospective observation study. Participants 30 perimetric glaucoma and 30 age-matched normal participants were included. Methods One eye of each participant was imaged using 6mm×6mm macular OCT angiography (OCTA) scan pattern by 70-kHz 840-nm spectral-domain OCT. Flow signal was calculated by the split-spectrum amplitude-decorrelation angiography algorithm (SSADA). A projection-resolved OCTA (PR-OCTA) algorithm was used to remove flow projection artifacts. Four en face OCTA slabs were analyzed: the superficial vascular complex (SVC), intermediate capillary plexus (ICP), deep capillary plexus (DCP) and all-plexus retina (SVC+ICP+DCP). The vessel density (VD), defined as the percentage area occupied by flow pixels, was calculated from en face OCTA. A novel algorithm was used to adjust the vessel density to compensate for local variations in OCT signal strength. Main Outcome Measures Macular retinal VD, ganglion cell complex (GCC) thickness, and visual field (VF) sensitivity. Results Focal capillary dropout could be visualized in the SVC, but not the ICP and DVP, in glaucomatous eyes. In the glaucoma group, the SVC and all-plexus retinal VD (mean±SD: 47.2%±7.1% and 73.5%±6.6%) were lower than the normal group (60.5%±4.0% and 83.2%±4.2%, both P <0.001, t test). The ICP and DCP VD were not significantly lower in the glaucoma group. Among the overall macular VD parameters, the SVC VD had the best diagnostic accuracy as measured by the area under the receiver operating characteristic curve (AROC). The accuracy was even better when the worse hemisphere (inferior or superior) was used, achieving an AROC of 0.983 and a sensitivity of 96.7% at a specificity of 95%. Among the glaucoma participants, the hemispheric SVC VD values were highly correlated with the corresponding GCC thickness and VF sensitivity (P<0.003). The reflectance compensation step in VD calculation significantly improved repeatability, normal population variation, and correlation with VF and GCC thickness. Conclusions Based on PR-OCTA, glaucoma preferentially affects perfusion in the SVC in the macula more than the deeper plexuses. Reflectance-compensated SVC VD measurement by PR-OCTA detected glaucoma with high accuracy and could be useful in the clinical evaluation of glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
The number of people with glaucoma worldwide in 2010 and 2020
Quigley, H. A. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.081224 · Cited by 7,394
Topography of ganglion cells in human retina
Curcio, C. A., & Allen, K. A. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.903000103 · Cited by 1,844
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Self-citationRetinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
Glaucomatous damage of the macula
Hood, D. C., Raza, A. S., de Moraes, C. G. V., Liebmann, J. M., & Ritch, R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.08.003 · Cited by 867
Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
Jia, Y., Wei, E., Wang, X., Zhang, X., Morrison, J. C., Parikh, M., Lombardi, L. H., Gattey, D. M., Armour, R. L., Edmunds, B., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.021 · Cited by 740
Self-citationImportant Causes of Visual Impairment in the World Today
Congdon, N. G. (2003) · JAMA · doi:10.1001/jama.290.15.2057 · Cited by 698
Detection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography
Tan, O., Chopra, V., Lu, A. T.-H., Schuman, J. S., Ishikawa, H., Wollstein, G., Varma, R., & Huang, D. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.05.025 · Cited by 665
Self-citationOptical Coherence Tomography Angiography of the Peripapillary Retina in Glaucoma
Liu, L., Jia, Y., Takusagawa, H. L., Pechauer, A. D., Edmunds, B., Lombardi, L., Davis, E., Morrison, J. C., & Huang, D. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.2225 · Cited by 657
Self-citation
Metadata
- Authors
- Takusagawa, H. L., Liu, L., Ma, K. N., Jia, Y., Gao, S. S., Zhang, M., Edmunds, B., Parikh, M., Tehrani, S., Morrison, J. C., & Huang, D.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 124
- Issue
- 11
- Pages
- 1589-1599
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2727205012
- Cited by
- 290
- References
- 28
- FWCI
- 28.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in Glaucoma. https://app.cochat.ai/papers/10.1016/j.ophtha.2017.06.002
- The paper
- Takusagawa, H. L., Liu, L., Ma, K. N., Jia, Y., Gao, S. S., Zhang, M., Edmunds, B., Parikh, M., Tehrani, S., Morrison, J. C., & Huang, D. (2017). Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in Glaucoma. Ophthalmology. https://doi.org/10.1016/j.ophtha.2017.06.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.