Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: Development and validation of a fully automated method to detect and quantify macular fluid in conventional OCT images. DESIGN: Development of a diagnostic modality. PARTICIPANTS: The clinical dataset for fluid detection consisted of 1200 OCT volumes of patients with neovascular age-related macular degeneration (AMD, n = 400), diabetic macular edema (DME, n = 400), or retinal vein occlusion (RVO, n = 400) acquired with Zeiss Cirrus (Carl Zeiss Meditec, Dublin, CA) (n = 600) or Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany) (n = 600) OCT devices. METHODS: A method based on deep learning to automatically detect and quantify intraretinal cystoid fluid (IRC) and subretinal fluid (SRF) was developed. The performance of the algorithm in accurately identifying fluid localization and extent was evaluated against a manual consensus reading of 2 masked reading center graders. MAIN OUTCOME MEASURES: Performance of a fully automated method to accurately detect, differentiate, and quantify intraretinal and SRF using area under the receiver operating characteristics curves, precision, and recall. RESULTS: The newly designed, fully automated diagnostic method based on deep learning achieved optimal accuracy for the detection and quantification of IRC for all 3 macular pathologies with a mean accuracy (AUC) of 0.94 (range, 0.91-0.97), a mean precision of 0.91, and a mean recall of 0.84. The detection and measurement of SRF were also highly accurate with an AUC of 0.92 (range, 0.86-0.98), a mean precision of 0.61, and a mean recall of 0.81, with superior performance in neovascular AMD and RVO compared with DME, which was represented rarely in the population studied. High linear correlation was confirmed between automated and manual fluid localization and quantification, yielding an average Pearson's correlation coefficient of 0.90 for IRC and of 0.96 for SRF. CONCLUSIONS: Deep learning in retinal image analysis achieves excellent accuracy for the differential detection of retinal fluid types across the most prevalent exudative macular diseases and OCT devices. Furthermore, quantification of fluid achieves a high level of concordance with manual expert assessment. Fully automated analysis of retinal OCT images from clinical routine provides a promising horizon in improving accuracy and reliability of retinal diagnosis for research and clinical practice in ophthalmology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Learning Deconvolution Network for Semantic Segmentation
Noh, H., Hong, S., & Han, B. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.178 · Cited by 4,422
Automated Identification of Diabetic Retinopathy Using Deep Learning
Gargeya, R., & Leng, T. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.02.008 · Cited by 1,362
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Maguire, M. G., Martin, D. F., Ying, G.-S., Jaffe, G. J., Daniel, E., Grunwald, J. E., Toth, C. A., Ferris, F. L., & Fine, S. L. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.03.045 · Cited by 708
Deep Learning Is Effective for Classifying Normal versus Age-Related Macular Degeneration OCT Images
Lee, C. S., Baughman, D. M., & Lee, A. Y. (2017) · Ophthalmology Retina · doi:10.1016/j.oret.2016.12.009 · Cited by 657
Garvin, M. K., Abramoff, M. D., Wu, X., Russell, S. R., Burns, T. L., & Sonka, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2016958 · Cited by 626
Elman, M. J., Ayala, A., Bressler, N. M., Browning, D., Flaxel, C. J., Glassman, A. R., Jampol, L. M., & Stone, T. W. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.08.047 · Cited by 562
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Self-citationChiu, S. J., Allingham, M. J., Mettu, P. S., Cousins, S. W., Izatt, J. A., & Farsiu, S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001172 · Cited by 377
Cited by
Clinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
Liu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
f-AnoGAN: Fast unsupervised anomaly detection with generative adversarial networks
Schlegl, T., Seeböck, P., Waldstein, S. M., Langs, G., & Schmidt-Erfurth, U. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.01.010 · Cited by 1,545
Self-citationArtificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
The impact of artificial intelligence in medicine on the future role of the physician
Ahuja, A. S. (2019) · PeerJ · doi:10.7717/peerj.7702 · Cited by 789
“an accurate means ‘‘for the differential detection of retinal fluid types across the most prevalent exudative macular diseases and OCT devices’’ (Schlegl et al., 2018).”
BackgroundArtificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
“In macular edema secondary to RVO, recent efforts have also used AI-based methods to analyze the predictive potential of OCT biomarkers.”
BackgroundMethodInfluentialSelf-citationDigital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
“Recently, new DL algorithms were adopted for use on optical coherence tomography (OCT) images (Medeiros et al., 2019; Schlegl et al., 2018; Kapoor et al., 2019), which may increase the sensitivity of detection at the early stage of disorders, especially in AMD and DR with the detection of diabetic…”
MethodDiabetic retinopathy: Looking forward to 2030
Tan, T.-E., & Wong, T. Y. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.1077669 · Cited by 511
Going Deep in Medical Image Analysis: Concepts, Methods, Challenges, and Future Directions
Altaf, F., Islam, S. M. S., Akhtar, N., & Janjua, N. K. (2019) · IEEE Access · doi:10.1109/access.2019.2929365 · Cited by 286
Schmidt-Erfurth, U., Garcia-Arumi, J., Gerendas, B. S., Midena, E., Sivaprasad, S., Tadayoni, R., Wolf, S., & Loewenstein, A. (2019) · Ophthalmologica · doi:10.1159/000502041 · Cited by 284
Self-citationRETOUCH: The Retinal OCT Fluid Detection and Segmentation Benchmark and Challenge
Bogunovic, H., Venhuizen, F., Klimscha, S., Apostolopoulos, S., Bab-Hadiashar, A., Bagci, U., Beg, M. F., Bekalo, L., Chen, Q., Ciller, C., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901398 · Cited by 273
Self-citationPrediction of Individual Disease Conversion in Early AMD Using Artificial Intelligence
Schmidt-Erfurth, U., Waldstein, S. M., Klimscha, S., Sadeghipour, A., Hu, X., Gerendas, B. S., Osborne, A., & Bogunovic, H. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-24106 · Cited by 215
Self-citationFully automated detection of retinal disorders by image-based deep learning
Li, F., Chen, H., Liu, Z., Zhang, X., & Wu, Z. (2019) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-018-04224-8 · Cited by 208
Li, F., Chen, H., Liu, Z., Zhang, X.-D., Jiang, M.-S., Wu, Z.-Z., & Zhou, K.-Q. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.006204 · Cited by 193
Artificial intelligence-based decision-making for age-related macular degeneration
Hwang, D.-K., Hsu, C.-C., Chang, K.-J., Chao, D., Sun, C.-H., Jheng, Y.-C., Yarmishyn, A. A., Wu, J.-C., Tsai, C.-Y., Wang, M.-L., et al. (2019) · Theranostics · doi:10.7150/thno.28447 · Cited by 189
Lu, W., Tong, Y., Yu, Y., Xing, Y., Chen, C., & Shen, Y. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.6.41 · Cited by 171
Exploiting epistemic uncertainty of anatomy segmentation for anomaly detection in retinal OCT
Seebock, P., Orlando, J. I., Schlegl, T., Waldstein, S. M., Bogunovic, H., Klimscha, S., Langs, G., & Schmidt-Erfurth, U. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2919951 · Cited by 164
“for segmentation of fluid [9], [10], drusen [11], hyperreflective material [12] or photoreceptor”
BackgroundSelf-citationLu, D., Heisler, M., Lee, S., Ding, G. W., Navajas, E., Sarunic, M. V., & Beg, M. F. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.02.011 · Cited by 161
Li, F., Liu, Z., Chen, H., Jiang, M., Zhang, X., & Wu, Z. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.6.4 · Cited by 144
Artificial intelligence promotes the diagnosis and screening of diabetic retinopathy
Huang, X., Wang, H., She, C., Feng, J., Liu, X., Hu, X., Chen, L., & Tao, Y. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.946915 · Cited by 115
Malik, H., Farooq, M. S., Khelifi, A., Abid, A., Nasir Qureshi, J., & Hussain, M. (2020) · IEEE Access · doi:10.1109/access.2020.3004766 · Cited by 104
Structured layer surface segmentation for retina OCT using fully convolutional regression networks
He, Y., Carass, A., Liu, Y., Jedynak, B. M., Solomon, S. D., Saidha, S., Calabresi, P. A., & Prince, J. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101856 · Cited by 104
“…et al. (2017) used a fully convolutional network (FCN) to label each pixel into eight layer classes, edema, and background; Lee et al. (2017a) and Schlegl et al. (2018) each used an FCN to segment retinal edema and fluids; and Venhuizen et al. (2017) used an FCN to segment the whole retina…”
MethodGonzález-Gonzalo, C., Thee, E. F., Klaver, C. C. W., Lee, A. Y., Schlingemann, R. O., Tufail, A., Verbraak, F., & Sánchez, C. I. (2022) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.101034 · Cited by 103
“Some studies have focused on resolving disagreements between graders and deriving consensus through supervision (Schlegl et al., 2018), majority decisions (Gulshan et al.”
Retinal specialist versus artificial intelligence detection of retinal fluid from OCT
Keenan, T. D. L., Clemons, T. E., Domalpally, A., Elman, M. J., Havilio, M., Agrón, E., Benyamini, G., & Chew, E. Y. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.06.038 · Cited by 93
Artificial Intelligence in Diabetic Eye Disease Screening
(2019) · Asia-Pacific Journal of Ophthalmology · doi:10.22608/apo.201976 · Cited by 82
Kaur, A., Singh, Y., Neeru, N., Kaur, L., & Singh, A. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09649-9 · Cited by 79
Volumetric measurement of subretinal blebs using microscope-integrated optical coherence tomography
Hsu, S. T., Gabr, H., Viehland, C., Sleiman, K., Ngo, H. T., Carrasco-Zevallos, O. M., Vajzovic, L., McNabb, R. P., Stinnett, S. S., Izatt, J. A., et al. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.2.19 · Cited by 36
Semi‐supervised classification of fundus images combined with CNN and GCN
Duan, S., Huang, P., Chen, M., Wang, T., Sun, X., Chen, M., Dong, X., Jiang, Z., & Li, D. (2022) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13746 · Cited by 29
Potapenko, I., Kristensen, M., Thiesson, B., Ilginis, T., Lykke Sørensen, T., Nouri Hajari, J., Fuchs, J., Hamann, S., & la Cour, M. (2022) · Acta Ophthalmologica · doi:10.1111/aos.14895 · Cited by 11
Metadata
- Authors
- Schlegl, T., Waldstein, S. M., Bogunovic, H., Endstraßer, F., Sadeghipour, A., Philip, A.-M., Podkowinski, D., Gerendas, B. S., Langs, G., & Schmidt-Erfurth, U.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 125
- Issue
- 4
- Pages
- 549-558
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2772059204
- Cited by
- 597
- References
- 32
- FWCI
- 30.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.