CoChat

Predicting Progression to Advanced Age-Related Macular Degeneration from Clinical, Genetic, and Lifestyle Factors Using Machine Learning

Open access
Ajana, Soufiane, Cougnard-Grégoire, Audrey, Colijn, Johanna M., Merle, Bénédicte M.J., Verzijden, Timo, de Jong, Paulus T.V.M., Hofman, Albert, Vingerling, Johannes R., Hejblum, Boris P., Korobelnik, Jean-François, Meester-Smoor, Magda A., Ueffing, Marius, Jacqmin-Gadda, Hélène, Klaver, Caroline C.W., Delcourt, Cécile, Acar, Erkin I., Arango-Gonzalez, Blanca, Armento, Angela, Badura, Franz, Bhatia, Vaibhav, Bhattacharya, Shomi S., Biarnés, Marc, Borrell, Anna, Calado, Sofia M., Dammeier, Sascha, de Breuk, Anita, De la Cerda, Berta, den Hollander, Anneke I., Diaz-Corrales, Francisco J., Diether, Sigrid, Emri, Eszter, Endermann, Tanja, Ferraro, Lucia L., Garcia, Míriam, Heesterbeek, Thomas J., Honisch, Sabina, Hoyng, Carel B., Kilger, Ellen, Kortvely, Elod, Lastrucci, Claire, Langen, Hanno, Lengyel, Imre, Luthert, Phil, Monés, Jordi, Nogoceke, Everson, Peto, Tunde, Pool, Frances M., Rodriguez-Bocanegra, Eduardo, Serrano, Luis, Sousa, Jose, Thee, Eric, Ueffing, Marius, Ulrich Bartz-Schmidt, Karl U., Zumbansen, Markus · 2021 · Ophthalmology
Cited by 62

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVE Current prediction models for advanced age-related macular degeneration (AMD) are based on a restrictive set of risk factors. The objective of this study was to develop a comprehensive prediction model, applying a machine learning algorithm allowing selection of the most predictive risk factors automatically. DESIGN Two population-based cohort studies PARTICIPANTS: The Rotterdam Study I (RS-I, training set) included 3838 participants aged 55 years or more, with a median follow-up period of 10.8 years and 108 incident cases of advanced AMD. The ALIENOR study (test set) included 362 participants aged 73 years or more, with a median follow-up period of 6.5 years and 33 incident cases of advanced AMD. METHODS The prediction model used the bootstrap lasso for survival analysis to select the best predictors of incident advanced AMD in the training set. Predictive performance of the model was assessed using the area under the receiver operating characteristic curve (AUC). MAIN OUTCOME MEASURES incident advanced AMD (atrophic and/or neovascular), based on standardized interpretation of retinal photographs. RESULTS The prediction model retained i) age, ii) a combination of phenotypic predictors (based on the presence of intermediate drusen, hyper-pigmentation in one or both eyes and age-related eye disease study (AREDS) simplified score), iii) a summary genetic risk score based on 49 single nucleotide polymorphisms, iv) smoking, v) diet quality, vi) education, and vii) pulse pressure. The cross-validated AUC estimation in RS-I was 0.92 [0.88-0.97] at 5 years, 0.92 [0.90-0.95] at 10 years and 0.91 [0.88-0.94] at 15 years. In ALIENOR, the AUC reached 0.92 at 5 years [0.87-0.98]. In terms of calibration, the model tended to underestimate the cumulative incidence of advanced AMD for the high-risk groups, especially in ALIENOR. CONCLUSIONS This prediction model reached high discrimination abilities, paving the way towards making precision medicine for AMD patients a reality in the near future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2020.08.031

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 62

Metadata

Authors
Ajana, S., Cougnard-Grégoire, A., Colijn, J. M., Merle, B. M. J., Verzijden, T., de Jong, P. T. V. M., Hofman, A., Vingerling, J. R., Hejblum, B. P., Korobelnik, J.-F., Meester-Smoor, M. A., Ueffing, M., Jacqmin-Gadda, H., Klaver, C. C. W., Delcourt, C., Acar, E. I., Arango-Gonzalez, B., Armento, A., Badura, F., Bhatia, V., Bhattacharya, S. S., Biarnés, M., Borrell, A., Calado, S. M., Dammeier, S., de Breuk, A., De la Cerda, B., den Hollander, A. I., Diaz-Corrales, F. J., Diether, S., Emri, E., Endermann, T., Ferraro, L. L., Garcia, M., Heesterbeek, T. J., Honisch, S., Hoyng, C. B., Kilger, E., Kortvely, E., Lastrucci, C., Langen, H., Lengyel, I., Luthert, P., Monés, J., Nogoceke, E., Peto, T., Pool, F. M., Rodriguez-Bocanegra, E., Serrano, L., Sousa, J., Thee, E., Ueffing, M., Ulrich Bartz-Schmidt, K. U., & Zumbansen, M.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2021-04
Volume
128
Issue
4
Pages
587-597
ISSN
0161-6420 (ISSN-L)
OpenAlex
W3082449889
Cited by
62
References
10
FWCI
5.64
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predicting Progression to Advanced Age-Related Macular Degeneration from Clinical, Genetic, and Lifestyle Factors Using Machine Learning. https://app.cochat.ai/papers/10.1016/j.ophtha.2020.08.031
The paper
Ajana, S., Cougnard-Grégoire, A., Colijn, J. M., Merle, B. M. J., Verzijden, T., de Jong, P. T. V. M., Hofman, A., Vingerling, J. R., Hejblum, B. P., Korobelnik, J.-F., Meester-Smoor, M. A., Ueffing, M., Jacqmin-Gadda, H., Klaver, C. C. W., Delcourt, C., Acar, E. I., Arango-Gonzalez, B., Armento, A., Badura, F., . . . Zumbansen, M. (2021). Predicting Progression to Advanced Age-Related Macular Degeneration from Clinical, Genetic, and Lifestyle Factors Using Machine Learning. Ophthalmology. https://doi.org/10.1016/j.ophtha.2020.08.031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.