CoChat

Myopia Control Effect of Repeated Low-Level Red-Light Therapy in Chinese Children

Open access
Dong, Jing, Zhu, Zhuoting, Xu, Haifeng, He, Mingguang · 2023 · Ophthalmology
Cited by 159

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

PURPOSE: Repeated low-level red-light (RLRL) therapy is an emerging treatment for myopia control. Nevertheless, previous studies are limited by open-label design. Our study aimed to assess the efficacy and safety of RLRL therapy in controlling myopia progression compared to a sham device with only 10% of the original power. DESIGN: Randomized, double-blind, controlled clinical trial. PARTICIPANTS: A total of 112 Chinese children aged 7 to 12 years with myopia of at least -0.50 diopter (D), astigmatism of 1.50 D or less, and anisometropia of 1.50 D or less. METHODS: Participants were assigned randomly in a 1:1 ratio to the RLRL group or the sham device control group, following a schedule of 3 minutes per session, twice daily, with an interval between sessions of at least 4 hours. The RLRL therapy was provided by a desktop red-light therapy device and administered at home. The sham device was the same device but with only 10% of the original device's power. Cycloplegic refraction and axial length (AL) were measured at baseline and 6 months. MAIN OUTCOME MEASURES: Changes in cycloplegic spherical equivalence refraction (SER) and AL between 2 groups were compared using a generalized estimating equation (GEE). RESULTS: A total of 111 children were included in the analysis (n = 56 in the RLRL group and n = 55 in the sham device control group). The mean SER change over 6 months was 0.06 ± 0.30 D in the RLRL group and -0.11 ± 0.33 D in the sham device control group (P = 0.003), with respective mean increases in AL of 0.02 ± 0.11 mm and 0.13 ± 0.10 mm (P < 0.001). In the multivariate GEE models, children in the RLRL group showed less myopia progression and axial elongation than those in the sham device control group (SER: coefficient, 0.167 D; 95% confidence interval [CI], 0.050-0.283 D; P = 0.005; AL: coefficient, -0.101 mm; 95% CI, -0.139 to -0.062 mm; P < 0.001). No treatment-related adverse events were reported. CONCLUSIONS: In myopic children, RLRL therapy with 100% power significantly reduced myopia progression over 6 months compared with those treated with a sham device of 10% original power. The RLRL treatment was well tolerated without treatment-related adverse effects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2022.08.024

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Dong, J., Zhu, Z., Xu, H., & He, M.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2023-02
Volume
130
Issue
2
Pages
198-204
ISSN
0161-6420 (ISSN-L)
OpenAlex
W4293474049
Cited by
159
References
8
FWCI
18.52
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.