Machine Learning to Analyze the Prognostic Value of Current Imaging Biomarkers in Neovascular Age-Related Macular Degeneration
Open accessAbstract
To evaluate the potential of machine learning to predict best-corrected visual acuity (BCVA) outcomes from structural and functional assessments during the initiation phase in patients receiving standardized ranibizumab therapy for neovascular age-related macular degeneration (AMD). Post hoc analysis of a randomized, prospective clinical trial. Data of 614 evaluable patients receiving intravitreal ranibizumab monthly or pro re nata according to protocol-specified criteria in the HARBOR trial. Monthly spectral-domain (SD) OCT volume scans were processed by validated, fully automated computational image analysis. This system performs spatially resolved 3-dimensional segmentation of retinal layers, intraretinal cystoid fluid (IRF), subretinal fluid (SRF), and pigment epithelial detachments (PED). The extracted quantitative OCT biomarkers and BCVA measurements at baseline and months 1, 2, and 3 were used to predict BCVA at 12 months using random forest machine learning. This approach was also used to correlate OCT morphology to BCVA at baseline (structure–function correlation). Accuracy (R2) of the prediction models; ranking of input variables. Computational image analysis enabled fully automated quantitative characterization of neovascular lesions in a large-scale clinical SD-OCT data set. At baseline, OCT features and BCVA were correlated with R2 = 0.21. The most relevant biomarker for BCVA was the horizontal extension of IRF in the foveal region, whereas SRF and PED ranked low. In predicting functional outcomes, the model's accuracy increased in a linear fashion with each month. If only the baseline visit was considered, the accuracy was R2 = 0.34. At month 3, final visual acuity outcomes could be predicted with an accuracy of R2 = 0.70. The strongest predictive factor for functional outcomes at 1 year was consistently the individual BCVA level during the initiation phase. In this large-scale study based on a wide spectrum of morphologic and functional features, baseline BCVA correlated modestly with baseline SD-OCT, whereas functional outcomes were determined by BCVA levels during the initiation phase with a minor influence of fluid-related features. This finding suggests a re-evaluation of current diagnostic imaging features and a search for novel imaging approaches, where machine learning is a promising approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Ranibizumab for Neovascular Age-Related Macular Degeneration
Rosenfeld, P. J., Brown, D. M., Heier, J. S., Boyer, D. S., Kaiser, P. K., Chung, C. Y., & Kim, R. Y. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054481 · Cited by 5,886
Predicting the future - big data, machine learning, and clinical medicine
Obermeyer, Z., & Emanuel, E. J. (2016) · New England Journal of Medicine · doi:10.1056/nejmp1606181 · Cited by 3,652
Ranibizumab versus Verteporfin for Neovascular Age-Related Macular Degeneration
Brown, D. M., Kaiser, P. K., Michels, M., Soubrane, G., Heier, J. S., Kim, R. Y., Sy, J. P., & Schneider, S. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa062655 · Cited by 3,522
Ranibizumab and bevacizumab for neovascular age-related macular degeneration
(2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102673 · Cited by 2,669
Busbee, B. G., Ho, A. C., Brown, D. M., Heier, J. S., Suñer, I. J., Li, Z., Rubio, R. G., & Lai, P. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.10.014 · Cited by 500
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Self-citationKaiser, P. K., Brown, D. M., Zhang, K., Hudson, H. L., Holz, F. G., Shapiro, H., Schneider, S., & Acharya, N. R. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.08.012 · Cited by 361
Jaffe, G. J., Martin, D. F., Toth, C. A., Daniel, E., Maguire, M. G., Ying, G.-S., Grunwald, J. E., & Huang, J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.01.073 · Cited by 294
(2014) · Ophthalmology · doi:10.1016/j.ophtha.2013.11.031 · Cited by 283
Sharma, S., Toth, C. A., Daniel, E., Grunwald, J. E., Maguire, M. G., Ying, G.-S., Huang, J., Martin, D. F., & Jaffe, G. J. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2015.12.002 · Cited by 231
Maguire, M. G., Daniel, E., Shah, A. R., Grunwald, J. E., Hagstrom, S. A., Avery, R. L., Huang, J., Martin, R. W., Roth, D. B., Castellarin, A. A., et al. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.03.017 · Cited by 93
Oliver-Fernandez, A., Bakal, J., Segal, S., Shah, G. K., Dugar, A., & Sharma, S. (2005) · Canadian Journal of Ophthalmology · doi:10.1016/s0008-4182(05)80074-2 · Cited by 50
Cited by
The potential for artificial intelligence in healthcare
Davenport, T., & Kalakota, R. (2019) · Future Healthcare Journal · doi:10.7861/futurehosp.6-2-94 · Cited by 3,800
Clinically applicable deep learning for diagnosis and referral in retinal disease
De Fauw, J., Ledsam, J. R., Romera-Paredes, B., Nikolov, S., Tomasev, N., Blackwell, S., Askham, H., Glorot, X., O’Donoghue, B., Visentin, D., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0107-6 · Cited by 2,639
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
f-AnoGAN: Fast unsupervised anomaly detection with generative adversarial networks
Schlegl, T., Seeböck, P., Waldstein, S. M., Langs, G., & Schmidt-Erfurth, U. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.01.010 · Cited by 1,545
Self-citationArtificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Metadata
- Authors
- Schmidt-Erfurth, U., Bogunovic, H., Sadeghipour, A., Schlegl, T., Langs, G., Gerendas, B. S., Osborne, A., & Waldstein, S. M.
- Venue
- Ophthalmology Retina
- Publisher
- Elsevier BV
- Published
- 2018-01
- Volume
- 2
- Issue
- 1
- Pages
- 24-30
- ISSN
- 2468-6530 (ISSN-L)
- OpenAlex
- W2621101817
- Cited by
- 199
- References
- 13
- FWCI
- 13.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.