Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 228

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Retinal Microvascular and Neurodegenerative Changes in Alzheimer’s Disease and Mild Cognitive Impairment Compared with Control Participants

Open access
Yoon, Stephen P., Grewal, Dilraj S., Thompson, Atalie C., Polascik, Bryce W., Dunn, Cynthia, Burke, James R., Fekrat, Sharon · 2019 · Ophthalmology Retina

Abstract

Purpose: To evaluate and compare the retinal microvasculature in the superficial capillary plexus (SCP) in persons with Alzheimer’s disease (AD), mild cognitive impairment (MCI), and cognitively intact controls using optical coherence tomography angiography (OCTA). Various OCT parameters were also compared. Design: Cross-sectional study. Participants: 70 eyes from 39 AD subjects, 72 eyes from 37 MCI subjects, and 254 eyes from 133 control subjects were enrolled. Methods: Subjects were imaged using the Zeiss Cirrus HD-5000 with AngioPlex. All subjects underwent cognitive evaluation with Mini Mental State Examination (MMSE). Main Outcome Measures: The vessel density (VD) and perfusion density (PD) in the SCP within the Early Treatment Diabetic Retinopathy Study (ETDRS) 6mm circle, 3mm circle, and 3mm ring were compared between groups. The foveal avascular zone (FAZ) area, central subfield thickness (CST), macular ganglion cell-inner plexiform layer (GC-IPL) thickness, and peripapillary retinal nerve fiber layer (RNFL) thickness were also compared. Results: AD subjects had a significantly decreased SCP VD and PD in the 3mm ring (p=0.001 and 0.002 respectively) and 3mm circle (p=0.003 and 0.004 respectively) as well as VD in the 6mm circle (p=0.047) when compared to MCI and a significantly decreased SCP VD and PD in the 3mm ring (p=0.008 and 0.004 respectively) and 3mm circle (p=0.015 and 0.009 respectively) as well as PD in the 6mm circle (p=0.033) when compared to cognitively intact controls. However, there was no difference in SCP VD or PD between MCI and controls (p>0.05). The FAZ area and CST did not significantly differ between groups (p>0.05). AD subjects had significantly decreased GC-IPL thickness over the inferior (p=0.032) and inferonasal (p=0.025) sectors compared to MCI subjects and significantly decreased GC-IPL thickness over the whole (p=0.012), superonasal (p=0.041), inferior (p=0.004), and inferonasal (p=0.006) sectors when compared to controls. MCI subjects had significantly decreased temporal RNFL thickness (p=0.04) compared to controls. Conclusions: AD subjects had significantly reduced macular VD, PD, and GC-IPL thickness compared to MCI and control subjects. Changes in the retinal microvasculature may mirror small vessel cerebrovascular changes in AD. These parameters may serve as surrogate non-invasive biomarkers in the diagnosis of AD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.oret.2019.02.002

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Yoon, S. P., Grewal, D. S., Thompson, A. C., Polascik, B. W., Dunn, C., Burke, J. R., & Fekrat, S.
Venue
Ophthalmology Retina
Publisher
Elsevier BV
Published
2019-06
Volume
3
Issue
6
Pages
489-499
ISSN
2468-6530 (ISSN-L)
OpenAlex
W2920900638
Cited by
228
References
7
FWCI
17.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.