CoChat

Failure of trabecular bone with simulated lytic defects can be predicted non‐invasively by structural analysis

Hong, James, Cabe, Greg D., Tedrow, John R., Hipp, John A., Snyder, Brian D. · 2004 · Journal of Orthopaedic Research
Cited by 91

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Pathologic fracture is a significant risk for patients afflicted with metastatic or benign skeletal tumors. The quandary for physicians who treat these patients is that after making the diagnosis they must try to predict the load bearing capacity of the involved bone and the fracture risk from images seen in radiological examinations. Since bone fails at a relatively constant strain independent of density we demonstrate that using a mechanics of materials approach that the cross‐sectional structural properties of the bone most affected by the lytic defect governs the load bearing capacity of the entire bone. Homogeneous cylindrical cores of trabecular bone were harvested from the vertebral bodies of whale spines, and prepared with circular or slotted through‐hole defects of varying sizes to simulate lytic skeletal tumors. Each specimen was imaged using quantitative computed tomography (CT), dual energy X‐ray absorptiometry (DXA), and magnetic resonance imaging (MRI) to obtain data for calculating cross‐sectional structural properties: axial, flexural, and torsional rigidity. The specimens were then divided into groups uniformly distributed with respect to defect sizes and shapes, and subjected to uniaxial tension, four‐point bending or torsion until failure. A strong positive relationship was found between measured tensile yield loads, bending, and torsional yield moments vs. axial, flexural and torsional structural rigidities respectively, calculated from QCT, DXA, and MRI data [QCT: tension r2 = 0.951, bending r2 = 0.909, torsion r2 = 0.914 (p < 0.001); DXA: tension r2 = 0.926, bending r2 = 0.841, torsion r2 = 0.916 (p < 0.001), MRI: tension r2 = 0.916; bending r2 = 0.856, torsion r2 = 0.852 (p < 0.001)]. For cylindrical cores of trabecular bone with simulated lytic defects, the load bearing capacity of the entire core was directly proportional to the axial, bending, or torsional rigidity at the weakest cross‐section through the core containing the defect. Therefore structural rigidity analysis of cross‐sectional geometric data measured non‐invasively by QCT, DXA, and MRI of bones containing lytic defects may be used to predict the load bearing capacity of the involved bone and the relative fracture risk in vivo. © 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.orthres.2003.09.006

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 91

Metadata

Authors
Hong, J., Cabe, G. D., Tedrow, J. R., Hipp, J. A., & Snyder, B. D.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2004-05
Volume
22
Issue
3
Pages
479-486
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2038484874
Cited by
91
References
3
FWCI
3.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.