Centrality of the Umbilical Cord Insertion in a Human Placenta Influences the Placental Efficiency
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Goal: We assess the effect on placental efficiency of the non-centrality of the umbilical cord insertion and on chorionic vascular distribution to determine if cord centrality measurably affects placental function as reflected in birth weight. Materials and Methods: 1,225 placentas collected from a prospective cohort had digital photographs of the chorionic plate. Of these, 1023 were term, 44 had velamentous cord insertion and 12 had missing clinical data, leaving N=967 (94.5 %) cases for analysis. Mathematical tools included a dynamical stochastic growth model of placental vasculature, Fourier analysis of radial parameterization of placental perimeters, and relative chorionic vascular density (a measure of “gaps” in the vascular coverage) derived from manual tracings of the fetal chorionic surface images. Bivariate correlations used Pearson's or Spearman's rank correlation as appropriate, with p<0.05 considered significant. Results: The correlation of the standard deviation of the placental radius (a measure of non-roundness of the placenta) with cord displacement was negligible (r=0.01). Empirical simulations of the vascular growth model with cord displacement showed no deviation from a normal round-to-oval placental shape for cord displacement of 10 – 50% of placental radius. The correlation of the metabolic scaling exponent β with cord displacement measured by Fourier analysis is 0.17 (p < 0.001). Analysis of the chorionic vascular density in traced images shows a high correlation of the relative vascular distance with cord displacement: 0.59 in one set of 12 images, and 0.20 in the other set of 28 images. Conclusion: Non-central cord insertion has little measurable correlation with placental shape in observed or simulated placentas. However, placentas with a displaced cord show a markedly reduced transport efficiency, reflected in a larger value of β and hence in a smaller birth weight for a given placental weight. Placentas with a non-central cord insertion have a sparser chorionic vascular distribution, as measured by the relative vascular distance. Even if typically a placenta with a non-central insertion is of a normal round shape, its vasculature is less metabolically effective. These findings demonstrate another method by which altered placental structure may affect the fetal environment, influencing birth weight and potentially contributing to later health risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Placental growth patterns affect birth weight for given placental weight
Salafia, C. M., Zhang, J., Miller, R. K., Charles, A. K., Shrout, P., & Sun, W. (2007) · Birth Defects Research Part A: Clinical and Molecular Teratology · doi:10.1002/bdra.20345 · Cited by 103 · cited 1×
“The present work extends our prior demonstrations that irregular placental shapes are associated with reduced birth weight for given placental weight – using both the relatively crude descriptions of ‘‘round/oval versus all other shapes’’ in the Collaborative Perinatal Project [5], or using the digital photographs tha…”
MethodSelf-citationModeling the Variability of Shapes of a Human Placenta
Yampolsky, M., Salafia, C. M., Shlakhter, O., Haas, D., Eucker, B., & Thorp, J. (2008) · Placenta · doi:10.1016/j.placenta.2008.06.005 · Cited by 96 · cited 8×
“Alterations in the basic proportions of the placental disk [2] as well as the structure of the vascular tree may decrease the optimality of the transport efficiency, and thus the efficacy by which placental mass functions to yield fetal mass [3].”
BackgroundMethodResultSelf-citation
Cited by
Pathophysiology of placental-derived fetal growth restriction
Burton, G. J., & Jauniaux, E. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.11.577 · Cited by 1,070
Optimising sample collection for placental research
Burton, G. J., Sebire, N. J., Myatt, L., Tannetta, D., Wang, Y.-L., Sadovsky, Y., Staff, A. C., & Redman, C. W. (2014) · Placenta · doi:10.1016/j.placenta.2013.11.005 · Cited by 263
Longtine, M., & Nelson, D. M. (2011) · Seminars in Reproductive Medicine · doi:10.1055/s-0031-1275515 · Cited by 165
Schwartz, N., Sammel, M. D., Leite, R., & Parry, S. (2014) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.02.033 · Cited by 80
Schwartz, N., Wang, E., & Parry, S. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.11136 · Cited by 49
Metadata
- Authors
- Yampolsky, M., Salafia, C. M., Shlakhter, O., Haas, D., Eucker, B., & Thorp, J.
- Venue
- Placenta
- Publisher
- Elsevier BV
- Published
- 2009-12
- Volume
- 30
- Issue
- 12
- Pages
- 1058-1064
- ISSN
- 0143-4004 (ISSN-L)
- OpenAlex
- W2034909815
- Cited by
- 125
- References
- 2
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.