Calibrating physical activity intensity for hip-worn accelerometry in women age 60 to 91years: The Women's Health Initiative OPACH Calibration Study
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We conducted a laboratory-based calibration study to determine relevant cutpoints for a hip-worn accelerometer among women ≥60 years, considering both type and filtering of counts. METHODS: Two hundred women wore an ActiGraph GT3X+ accelerometer on their hip while performing eight laboratory-based activities. Oxygen uptake was measured using an Oxycon portable calorimeter. Accelerometer data were analyzed in 15-second epochs for both normal and low frequency extension (LFE) filters. Receiver operating characteristic (ROC) curve analyses were used to calculate cutpoints for sedentary, light (low and high), and moderate to vigorous physical activity (MVPA) using the vertical axis and vector magnitude (VM) counts. RESULTS: Mean age was 75.5 years (standard deviation 7.7). The Spearman correlation between oxygen uptake and accelerometry ranged from 0.77 to 0.85 for the normal and LFE filters and for both the vertical axis and VM. The area under the ROC curve was generally higher for VM compared to the vertical axis, and higher for cutpoints distinguishing MVPA compared to sedentary and light low activities. The VM better discriminated sedentary from light low activities compared to the vertical axis. The area under the ROC curves were better for the LFE filter compared to the normal filter for the vertical axis counts, but no meaningful differences were found by filter type for VM counts. CONCLUSION: The cutpoints derived for this study among women ≥60 years can be applied to ongoing epidemiologic studies to define a range of physical activity intensities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guralnik, J. M., Simonsick, E. M., Ferrucci, L., Glynn, R. J., Berkman, L. F., Blazer, D. G., Scherr, P. A., & Wallace, R. B. (1994) · Journal of Gerontology · doi:10.1093/geronj/49.2.m85 · Cited by 9,792
The Physical Activity Guidelines for Americans
Piercy, K. L., Troiano, R. P., Ballard, R. M., Carlson, S. A., Fulton, J. E., Galuska, D. A., George, S. M., & Olson, R. D. (2018) · JAMA · doi:10.1001/jama.2018.14854 · Cited by 9,755
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
(2007) · Circulation · doi:10.1161/circulationaha.107.185649 · Cited by 6,545
Self-citationCalibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677 · cited 1×
“In prior studies, the more common approach was to choose cutpoints by onlymaximizing the sumof sensitivity and specificity, or equivalently minimizing the overall misclassification rate (Evenson et al., 2008).”
Self-citationAccelerated longitudinal decline of aerobic capacity in healthy older adults
Fleg, J. L., Morrell, C. H., Bos, A. G., Brant, L. J., Talbot, L. A., Wright, J. G., & Lakatta, E. G. (2005) · Circulation · doi:10.1161/circulationaha.105.545459 · Cited by 970
Lyden, K., Kozey, S. L., Staudenmeyer, J. W., & Freedson, P. S. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1639-8 · Cited by 222
Accelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174 · cited 3×
“The activities performed were common towomen of similar ages (Hooker et al., 2011; Kozey et al., 2010b).”
BackgroundInfluentialKozey, S., Lyden, K., Staudenmayer, J., & Freedson, P. (2010) · Journal of Physical Activity and Health · doi:10.1123/jpah.7.4.508 · Cited by 119 · cited 3×
“The activities performed were common towomen of similar ages (Hooker et al., 2011; Kozey et al., 2010b).”
BackgroundInfluential
Cited by
Ekelund, U., Tarp, J., Steene-Johannessen, J., Hansen, B. H., Jefferis, B., Fagerland, M. W., Whincup, P., Diaz, K. M., Hooker, S. P., Chernofsky, A., et al. (2019) · BMJ · doi:10.1136/bmj.l4570 · Cited by 1,769
Self-citationSedentary Behavior and Cardiovascular Disease in Older Women: The OPACH Study
Bellettiere, J., LaMonte, M. J., Evenson, K. R., Rillamas-Sun, E., Kerr, J., Lee, I.-M., Di, C., Rosenberg, D. E., Stefanick, M. L., Buchner, D. M., et al. (2019) · Circulation · doi:10.1161/circulationaha.118.035312 · Cited by 252
Self-citationLaCroix, A. Z., Bellettiere, J., Rillamas-Sun, E., Di, C., Evenson, K. R., Lewis, C. E., Buchner, D. M., Stefanick, M. L., Lee, I.-M., Rosenberg, D. E., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.0419 · Cited by 162
LaMonte, M. J., Lewis, C. E., Buchner, D. M., Evenson, K. R., Rillamas‐Sun, E., Di, C., Lee, I., Bellettiere, J., Stefanick, M. L., Eaton, C. B., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.007064 · Cited by 97
“A major strength of this investigation is use of a triaxial accelerometer to improve measurement sensitivity to activity patterns of lower intensity that are typical among older women.(10,28) Additionally, the use of accelerometer count thresholds to define PA intensity levels determined in a laboratory calibration am…”
BackgroundSelf-citationAccelerometer‐Measured Physical Activity and Mortality in Women Aged 63 to 99
LaMonte, M. J., Buchner, D. M., Rillamas‐Sun, E., Di, C., Evenson, K. R., Bellettiere, J., Lewis, C. E., Lee, I., Tinker, L. F., Seguin, R., et al. (2018) · Journal of the American Geriatrics Society · doi:10.1111/jgs.15201 · Cited by 94
“Use of triaxial accelerometers allowed detection of movement in three planes, whereas studies using uniaxial devices detect movement in a single plane (as in NHANES), which could be less sensitive to movement patterns and intensities of daily life(33) among older adults.(17) Accelerometer intensity thresholds were det…”
BackgroundSelf-citation
Metadata
- Authors
- Evenson, K. R., Wen, F., Herring, A. H., Di, C., LaMonte, M. J., Tinker, L. F., Lee, I.-M., Rillamas-Sun, E., LaCroix, A. Z., & Buchner, D. M.
- Venue
- Preventive Medicine Reports
- Publisher
- Elsevier BV
- Published
- 2015
- Volume
- 2
- Pages
- 750-756
- ISSN
- 2211-3355 (ISSN-L)
- OpenAlex
- W1641346875
- Cited by
- 136
- References
- 9
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibrating physical activity intensity for hip-worn accelerometry in women age 60 to 91years: The Women's Health Initiative OPACH Calibration Study. https://app.cochat.ai/papers/10.1016/j.pmedr.2015.08.021
- The paper
- Evenson, K. R., Wen, F., Herring, A. H., Di, C., LaMonte, M. J., Tinker, L. F., Lee, I.-M., Rillamas-Sun, E., LaCroix, A. Z., & Buchner, D. M. (2015). Calibrating physical activity intensity for hip-worn accelerometry in women age 60 to 91years: The Women's Health Initiative OPACH Calibration Study. Preventive Medicine Reports. https://doi.org/10.1016/j.pmedr.2015.08.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.