Pros and cons of ultra-high-field MRI/MRS for human application
Open accessThe DOI matches its Crossref record; 596 of the 599 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These experimental errors also affect NMR and MRI at high and ultra-high magnetic fields as they require high-fidelity levels for coherent and high-efficiency control of heterogeneous spin ensembles (9, 10).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
In the citing paper
“The latter shows that the algorithm has the potential to generate ultra low-power pulses for MRI, where power deposition becomes a problem for human subjects (9).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
In the citing paper
“RF inhomogeneity represents a severe problem for MRI both at low and high magnetic fields, limiting both the resolution and sensitivity of images (9).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
In the citing paper
“In theory, it is possible to generate ultra-BB pulses for a range of very large BWs (9).”
From High-Fidelity Control of Spin Ensemble Dynamics via Artificial Intelligence: From Quantum Computing to Imaging (2021) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Cited by
Items 401–500 of 650
Multiple Sclerosis Imaging at 7T: Does 7T MRI Teach Us Something New in MS Imaging?
Fullerton, N., Keith, G. A., Hopkins, T. J., Woodward, R. A., Martin, S., Chavada, G., MacDougall, N., Shah, P., O’Leary, C., Porter, D. A., et al. (2024) · Neurographics · doi:10.3174/ng.2300055 · Cited by 2
Fourier‐based decomposition for simultaneous 2‐voxel MRS acquisition with 2SPECIAL
Riemann, L. T., Aigner, C. S., Mekle, R., Speck, O., Rose, G., Ittermann, B., Schmitter, S., & Fillmer, A. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29369 · Cited by 2
Self-citationApproaches for Image Reconstruction in Low-Field Magnetic Resonance ImagingPreprint
Obungoloch, J., & Ahishakiye, E. (2021) · Research Square · doi:10.21203/rs.3.rs-1127552/v1 · Cited by 2
Capteur IRM 3D multifonctionnel plastronique pour l’ingénierie tissulaire
Gnanago, J.-L. (2023) · theses.fr (ABES) · doi:10.70675/df5ace3czf2b8z4df7z9a5ezfbc42682da8e · Cited by 2
Imaging Approaches in Cancer Biology
Rajbhandari, N., Diaz, E., Kritzik, M. R., & Reya, T. (2024) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a041349 · Cited by 2
An electrophilicity-engineered magnetic sensor for MRI detection of dormant tumor cell clusters
Liang, Z., Zhang, B., Liu, X., Xiao, L., Xie, S., Du, H., Wang, Q., Li, F., & Ling, D. (2026) · Science Advances · doi:10.1126/sciadv.aea5236 · Cited by 2
High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing
Runderkamp, B. A., Caan, M. W. A., van der Zwaag, W., Hemke, R., Maas, M. M., Andersen, M., Strijkers, G. J., Bloch, K. M., & Nederveen, A. J. (2025) · NMR in Biomedicine · doi:10.1002/nbm.70041 · Cited by 2
New horizons: Human MRI at extremely high field strengths
Norris, D. G., & Ladd, M. E. (2023) · Advances in magnetic resonance technology and applications · doi:10.1016/b978-0-323-99898-7.00023-7 · Cited by 2
Self-citationTechnological Progress in Magnetic Resonance Imaging
Lagutin, A. S., & Grigoriev, G. Y. (2025) · Meditsinskaya Fizika · doi:10.52775/1810-200x-2025-106-2-102-127 · Cited by 2
Revisiting meniscal anatomical variants of the knee: a high-resolution 7-Tesla MRI study
Marcus, R. P., Marth, A. A., Fritz, B., Zimmermann, S. M., Nanz, D., & Sutter, R. (2025) · European Radiology · doi:10.1007/s00330-025-12090-2 · Cited by 2
Hardy, B. M., Banik, R., Yan, X., & Anderson, A. W. (2022) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2022.07.009 · Cited by 2
Behavioural disinhibition in the syndromes associated with frontotemporal lobar degeneration
Murley, A. G. (2020) · Apollo (University of Cambridge) · doi:10.17863/cam.58738 · Cited by 2
Egorova, S. S., Lisachenko, N. A., Kretov, E. I., Gao, Y., Zhang, X., Glybovski, S., & Solomakha, G. (2025) · IEEE Access · doi:10.1109/access.2025.3536361 · Cited by 2
In vivo evaluation of population‐specific inversion pulses in parallel transmission
Tyshchenko, I., Lévy, S., Bartlett, J. J., Tahayori, B., Blunck, Y., Sava, T. V., Chow, K., Liebig, P. A., Glarin, R. K., & Johnston, L. A. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30593 · Cited by 2
Combining Dipole and Loop Coil Elements for 7 T Magnetic Resonance Studies of the Human Calf Muscle
Cap, V., dos Santos, V. R. R., Repnin, K., Červený, D., Laistler, E., Meyerspeer, M., & Frass‐Kriegl, R. (2024) · Sensors · doi:10.3390/s24113309 · Cited by 2
Self-citationConventional and Advanced MRI in Neuro-Oncology
Tang, P. L. Y., Warnert, E. A. H., & Smits, M. (2024) · Springer eBooks · doi:10.1007/978-3-031-59341-3_2 · Cited by 2
Dental ve Maksillofasial Manyetik Rezonans Görüntüleme güncel bilgiler
Yılmaz, S. (2022) · Selcuk Dental Journal · doi:10.15311/selcukdentj.860805 · Cited by 2
Tunable Metasurfaces for Switchable Magnetic Field Enhancement Regions in 1.5 T MRI
Chen, G., Xiao, X., Liu, Y., Kong, X., & Zhou, J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3618475 · Cited by 2
Safety Issues in Magnetic Resonance Imaging: a Brief Overview
Lagutin, A. S., & Grigoriev, G. Y. (2025) · Medical Radiology and radiation safety · doi:10.33266/1024-6177-2025-70-6-45-53 · Cited by 2
Miranda, V., Carluccio, G., Ruello, G., Lattanzi, R., & Riccio, D. (2026) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-026-01335-w · Cited by 2
Seginer, A., Keith, G. A., Porter, D. A., & Schmidt, R. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29373 · Cited by 2
Zaaraoui, W., & Nagel, A. M. (2023) · Advances in magnetic resonance technology and applications · doi:10.1016/b978-0-323-99898-7.00015-8 · Cited by 2
Self-citationThe development of a fully MRI-compatible silicon carbide neural interface
Beygi, M., Dominguez‐Viqueira, W., Mumcu, G., Frewin, C. L., Via, F. L., & Saddow, S. E. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90609-8.00003-x · Cited by 2
Bäuchle, T. A., Stuprich, C., Loh, M., Nagel, A. M., Uder, M., & Laun, F. B. (2024) · Tomography · doi:10.3390/tomography10050059 · Cited by 2
Self-citationDual-tuned floating solenoid balun for multi-nuclear MRI and MRS
Yang, Y., Zhang, B., Lu, M., & Yan, X. (2024) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2024.110268 · Cited by 2
Coaxial Dipole Array With Switching Transmit Sensitivities for Ultrahigh Field MRI
Bosch, D., Solomakha, G., Glang, F., Freudensprung, M., Avdievich, N. I., & Scheffler, K. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70243 · Cited by 2
Özdede, M., & Yılmaz, S. (2020) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2020.07.009 · Cited by 2
Static Magnetic Fields on Human Bodies
Zhang, X. (2023) · Springer eBooks · doi:10.1007/978-981-19-8869-1_8 · Cited by 1
Wang, Y., Wang, X., Cai, X., Wang, L., Zhao, Y., Wang, L., Mao, W., Wei, Z., Zong, F., Wang, Y., et al. (2025) · PsyCh Journal · doi:10.1002/pchj.70029 · Cited by 1
fMRI at ultra-high field: From acquisition to interpretation
Goense, J. B. M., & Nothnagel, N. (2026) · Neuron · doi:10.1016/j.neuron.2026.04.025 · Cited by 1
Borza, D. B., Fărcășanu, A. Ș., Şimon, S., Mureșan, D., Rotar, I. C., Surcel, M., & Oancea, M. D. (2026) · Medical Sciences · doi:10.3390/medsci14020219 · Cited by 1
Diffusion MRI acquisition for tractography: Diffusion encoding
Campbell, J. S. W., Baete, S. H., Cohen‐Adad, J., Tournier, J., Szczepankiewicz, F., Beaulieu, C., Baron, C. A., Mani, M., Setsompop, K., Liao, C., et al. (2025) · Elsevier eBooks · doi:10.1016/b978-0-12-818894-1.00001-x · Cited by 1
Translational Value of Proton MRS in Depression: Applications to Preclinical Models
Harastova-Pavlova, I., & Kučerová, J. (2024) · Springer eBooks · doi:10.1007/978-3-031-32035-4_39-1 · Cited by 1
Chemical shift–based prospective k‐space anonymization
Mattern, H., Knoll, M., Lüsebrink, F., & Speck, O. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28460 · Cited by 1
Self-citationBeygi, M. (2020) · Digital Commons - University of South Florida (University of South Florida) · Cited by 1
Presurgical Functional Localization Possibilities, Limitations, and Validity
Chougar, L., Leclercq, D., de Moortele, P. V., & Lehéricy, S. (2021) · Medical radiology · doi:10.1007/978-3-030-83343-5_9 · Cited by 1
Fluorescent Probes for the Detection of Bone Metabolism
Zhang, J., Pan, S., Song, B., Xu, Y., Wang, H., & He, Y. (2023) · Analysis & Sensing · doi:10.1002/anse.202300057 · Cited by 1
Hepatokines and hepatic lipids: interaction with exercise, diet and metabolic health
Willis, S. (2020) · Figshare · doi:10.26174/thesis.lboro.13214129 · Cited by 1
Lemmens, M.-J. D. K., van Lanen, R. H. G. J., Uher, D., Colon, A., Hoeberigs, M. C., Hoogland, G., Roebroeck, A. F., Ivanov, D., Poser, B. A., Rouhl, R. P. W., et al. (2025) · Neuroradiology · doi:10.1007/s00234-024-03474-0 · Cited by 1
MR-based techniques for imaging prostate cancer metabolism: current status and future perspectives
Cheng, X., Xu, J., Yao, J., & Song, B. (2026) · Abdominal Radiology · doi:10.1007/s00261-025-05373-1 · Cited by 1
Kuijs, M., Jutzeler, C. R., Rieck, B., & Brüningk, S. C. (2021) · arXiv · doi:10.48550/arxiv.2111.08701 · Cited by 1
Gupta, J., Dey, A., Bhowmik, T., Bhattacharjee, R., Kanagaraj, S., & Sikdar, D. (2025) · IEEE Guwahati Subsection Conference (GCON) · doi:10.1109/gcon65540.2025.11173359 · Cited by 1
FMRI In Patients With Implanted Electrodes: Mitigating Imaging Artifacts
Weldemeskel, I. (2025) · doi:10.11575/prism/48832 · Cited by 1
Nikulin, A. (2020) · theses.fr (ABES) · doi:10.70675/cea4ca29zdfa5z4921zb3a6z05ff899f0463 · Cited by 1
(2019) · Arizona State University Library Digital Repository (Arizona State University) · Cited by 1
Spicher, N. (2020) · DuEPublico (University of Duisburg-Essen) · doi:10.17185/duepublico/72858 · Cited by 1
Comparison of commercial 1Tx32Rx vs. 8Tx32Rx head coils for routine 7T neuroimaging
Graf, C., Ding, B., Rua, C., Kłodowski, K., & Rodgers, C. T. (2026) · Frontiers in Neuroimaging · doi:10.3389/fnimg.2026.1736950 · Cited by 1
Monitoring Glycolysis by Endogenous 31P CEST Magnetic Resonance Imaging
Vassallo, G., Fiorucci, C., Garello, F., Aime, S., & Castelli, D. D. (2025) · Angewandte Chemie · doi:10.1002/ange.202501189 · Cited by 1
Ultimate Intrinsic SNR in the Torso of Realistic Body Models
Wang, Y., May, M. W., Gratz, M., Ladd, M. E., & Orzada, S. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70202 · Cited by 1
Self-citationAn evaluation of the coax monopole antenna as a transmit array element for head imaging at 14 T
Budé, L. M. I., Vat, K., Voogt, I. J., Zivkovic, I., & Raaijmakers, A. J. E. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30464 · Cited by 1
Hoerr, V., Nahardani, A., & Rasche, V. (2022) · Advances in magnetic resonance technology and applications · doi:10.1016/b978-0-12-824460-9.00006-6 · Cited by 1
Weng, G., & Slotboom, J. (2025) · Physical Review Applied · doi:10.1103/j138-v9gr · Cited by 1
A Hands-On Workshop for Constructing a Low-Field MRI System in Three DaysPreprint
Oiye, I. E., Sharma, A. P., Mohanta, Z., Sankaralayam, D. S., Uchida, Y., Akinwale, T., Wang, K., Xu, Z., Shuai, Y., Dinh, V., et al. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2511.20979 · Cited by 1
Kronlage, C., Ripart, M., Piper, R. J., Tisdall, M. M., Carmichael, D. W., Baldeweg, T., Duncan, J. S., O’Muircheartaigh, J., Eriksson, M. H., Casella, C., et al. (2026) · medRxiv · doi:10.64898/2026.08.27.26356343 · Cited by 1
Liu, J., Wang, M., Wang, W., Wang, Y., Yang, W., Wang, W., & Liu, F. (2025) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2025.107951 · Cited by 1
Zhou, M., Jamzad, A., Izard, J., Ménard, A., Siemens, R. D., & Mousavi, P. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2307.00479 · Cited by 1
Karaca, S. (2020) · Bilecik Şeyh Edebali University Institutional Repository · Cited by 1
Sánchez, M., Dietrich, S., Bassenge, J. P., Schulz‐Menger, J., Schmitter, S., & Aigner, C. S. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30495 · Cited by 1
Self-citationValencia, S. A., Machado‐Rivas, F., Cortés-Albornoz, M. C., Cartmell, S. C. D., Griffin, H., Orbach, D. B., Rameh, V., See, A. P., Warfield, S. K., Afacan, O., et al. (2025) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8908 · Cited by 1
Overcoming Low‐Field Limitations: High‐Quality Ex Vivo Soft Tissue Imaging with Compact MRI Systems
Litwak, A., Sarabia, A., Tamboline, M., Hili, R., & Xu, S. (2026) · Current Protocols · doi:10.1002/cpz1.70288 · Cited by 1
Cap, V., dos Santos, V. R. R., Repnin, K., Soanca, O., Laistler, E., Wolf, P. S., Kemp, G. J., Frass‐Kriegl, R., & Meyerspeer, M. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70249 · Cited by 1
Self-citationDouble-Structure Dielectrics for Efficient Traveling-Wave Magnetic Resonance Imaging
Pan, S., Yu, M., Liu, T., Zhang, X., & Gao, Y. (2026) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2026.3652507 · Cited by 1
Montemayor, N. P., Philippe, J., Kent, J. L., Hess, A. T., Klauser, A., Sleight, E., Bacha, L., Noto, T. D., Maréchal, B., Liebig, P. A., et al. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70289 · Cited by 1
Yang, S., Huang, Y., Guo, F., Yang, B. T., Tang, R., Guo, J., Gong, S., Liu, Y., Wang, Z., & Zhao, P. (2026) · American Journal of Neuroradiology · doi:10.3174/ajnr.a9329 · Cited by 1
Perspektiven der X-Kern-Magnetresonanztomographie in der Neuroonkologie
Regnery, S., & Platt, T. (2020) · Der Radiologe · doi:10.1007/s00117-020-00753-8 · Cited by 1
Minimum Volume Optimal Design Method of Hybrid MRI Magnet
Liu, Q., Lee, S., Choi, K., & Hahn, S. (2021) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2021.3066325 · Cited by 1
Numerical Investigation of Bore-Integrated Patch Antenna Array for 7 Tesla MRI
Egorova, S. S., Kretov, E. I., Lisachenko, N. A., Glybovski, S., & Solomakha, G. (2023) · Antennas Design and Measurement International Conference (ADMInC) · doi:10.1109/adminc59462.2023.10335276 · Cited by 1
Electric field measurements in preclinical MRI at 11.7 T and 7 T for experimental SAR comparison
Nobre, P., Gaborit, G., Troia, A., Zanovello, U., Duvillaret, L., & Beuf, O. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.171818 · Cited by 1
Experimental Assessment of Magnetic Resonance Imaging Distortion for Radiation Therapy Planning
Лыкова, Е. Н., Shcherbakov, A. A., Strelkovskaya, A. P., Студеникин, Ф. Р., Gavrilova, S. A., & Chernyaev, A. P. (2024) · Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya · doi:10.55959/msu0579-9392.79.2440703 · Cited by 1
Design of a 13-Channel Hybrid Array System for Foot/Ankle Magnetic Resonance Imaging at 7T/300MHzPreprint
Bhosale, A., Ying, L. L., & Zhang, X. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2205.14785 · Cited by 1
Bhosale, A., Ying, L. L., & Zhang, X. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2208.11759 · Cited by 1
Norris, D. G. (2024) · Elsevier eBooks · doi:10.1016/b978-0-12-820480-1.00157-1 · Cited by 1
Self-citationEmpirical validation of optic nerve tethering by horizontal duction
Seongjin, L. (2023) · eScholarship (California Digital Library) · Cited by 1
Multimodal concentric surface coils for enhanced sensitivity in MR imagingPreprint
Zhao, Y., Bhosale, A. A., & Zhang, X. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2508.14363 · Cited by 1
Borderies, N. (2020) · theses.fr (ABES) · doi:10.70675/03f23bddzae42z426aza9e6z34fb21ff3d9e
Integration and non-intrusive human clinic machine learning for kidney assessment
Do, Q. H. (2022) · theses.fr (ABES) · doi:10.70675/9cd78602z555bz4e01zb479zdb4b46f80000
Volumetric B 1 + Field Homogenization in 7 T Brain MRI Using Metasurface Scattering
Yoon, K., Yu, S., Lee, J., & Park, N. (2026) · ACS Photonics · doi:10.1021/acsphotonics.5c02781
Ye, L., Yu, Y., & Yan, D. (2026) · iScience · doi:10.1016/j.isci.2026.115369
Surgical management of CD: Techniques, complications, and recovery
Laws, M. T., Rampalli, I., & Chittiboina, P. (2026) · Elsevier eBooks · doi:10.1016/b978-0-323-96100-4.00003-x
Baptista, R. P. (2022) · theses.fr (ABES) · doi:10.70675/385e3c66za09dz48d2zb760z464ab94c6227
Analyse avancée de signaux ECG acquis en IRM
Aublin, P. G. (2023) · theses.fr (ABES) · doi:10.70675/3ac35dccz80f7z4580z9c4cz49d3a94f13cc
Fritz, F. J. (2020) · Research Publications (Maastricht University) · doi:10.26481/dis.20210111flf
Buča, B., Booker, C., & Jaksch, D. (2021) · SciPost Physics · doi:10.21468/scipost.report.3946
Buča, B., Booker, C., & Jaksch, D. (2021) · SciPost Physics · doi:10.21468/scipost.report.4024
Buča, B., Booker, C., & Jaksch, D. (2021) · SciPost Physics · doi:10.21468/scipost.report.3106
Buča, B., Booker, C., & Jaksch, D. (2021) · SciPost Physics · doi:10.21468/scipost.report.3082
Buča, B., Booker, C., & Jaksch, D. (2021) · SciPost Physics · doi:10.21468/scipost.report.3002
Presurgical focus localization in epilepsy
Mouthaan, B. E. (2022) · Utrecht University Repository (Utrecht University) · doi:10.33540/964
Computational Unfolding of the Human Hippocampus
DeKraker, J. (2020) · Scholarship@Western (Western University)
Improving Signal to Noise Ratio in Ultra High Field Magnetic Resonance ImagingPreprint
Tavaf, N. (2021) · Thesis Commons (OSF Preprints) · doi:10.31237/osf.io/za3ch
Pan, F., Liu, X., Wan, J., Guo, Y., Sun, P., Zhang, X., Wang, J., Bao, Q., & Yang, L. (2024) · Figshare · doi:10.6084/m9.figshare.26708231
Gallinnis, P. J., Möller, R., Ljimani, A., Cabuk, Y., Scheuer, M., Böttger, C., Liang, C., Nagel, A. M., Bechler, E., Wittsack, H., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30525
Self-citationA Comparative Study of Consistency on 1.5-T to 3.0-T Magnetic Resonance Imaging Conversion
Li, J., Zhang, Y., Chen, J., Liu, W., Wang, Y., & Zheng, Z. (2025) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/0115734056383931250919073319
Heiss, R., Weber, M.-A., Balbach, E. L., Hinsen, M., Geissler, F., Nagel, A. M., Ladd, M. E., Arkudas, A., Horch, R. E., Gall, C., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26652903
Self-citationTan, H., Wang, P., Zhang, R., Zong, S., Song, X., Zeng, W., Du, L., Xiong, Y., Wang, Y., & Li, Y. (2026) · NeuroImage · doi:10.1016/j.neuroimage.2026.122111
Zuo, J., Yang, H., Tang, Y., Wang, X., Zhong, K., Peng, X., & Luo, J. (2026) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2026.110815
Advanced Magnetic Resonance Imaging Techniques for Epilepsy: A Narrative Review
Perillo, T., & Perillo, S. (2024) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-024-01705-2
Structural Magnetic Resonance Imaging
Rivas‐Fernández, M. Á., & Basanta-Torres, S. (2026) · Neuromethods · doi:10.1007/978-1-0716-5340-1_8
Translational Value of Proton MRS in Depression: Applications to Preclinical Models
Harastova-Pavlova, I., & Kučerová, J. (2025) · Springer eBooks · doi:10.1007/978-3-031-73368-0_39
Metadata
- Authors
- Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M.
- Venue
- Progress in Nuclear Magnetic Resonance Spectroscopy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 109
- Pages
- 1-50
- ISSN
- 0079-6565 (ISSN-L)
- OpenAlex
- W2806074443
- Cited by
- 544
- References
- 599
- FWCI
- 27.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.