Abstract

A change in the crystallinity of short-carbon-fiber-reinforced polyether ether ketone (CF/PEEK) composites has a significant effect on the shrinkage deformation characteristics and mechanical properties of the components that are fabricated using 3D printing of CF/PEEK composites. In this study, we propose a novel process for controlling the crystallinity of 3D-printed CF/PEEK composites. First, components of a CF/PEEK composite with low crystallinity and warping deformation were 3D printed at a normal ambient temperature (20 °C). Second, the crystallinity and mechanical properties of the composite were quantitatively controlled via a recrystallization process. Finally, the mechanical properties of the CF/PEEK composite (10 wt%) were found to be similar to those of the materials fabricated via the injection molding process. This research work is of positive significance to promote the application of 3D printed PEEK composite materials in the field of aerospace and orthopedic implants.

Integrity signals

Registry

Crossref · 10.1016/j.polymertesting.2021.107149

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Adding chopped carbon fiber can simplify the printing process by forming a more uniform heat distribution and reducing warpage caused by thermal stresses.

    “and simplify the printing process by forming a more uniform heat distribution in the part while printing, reducing the probability of warpage caused by thermal stresses [188].”

Cites

Flagged first, then by citations

2 of the 37 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Yang, D., Cao, Y., Zhang, Z., Yin, Y., & Li, D.
Affiliations
Xi'an Jiaotong University (CN)
Corresponding author
Cao, Yi
Venue
Polymer Testing
Publisher
Elsevier BV
Published
2021-05
Volume
97
Pages
107149
ISSN
0142-9418 (ISSN-L)
OpenAlex
W3138080596
Cited by
155
References
37
Citations by year
2026: 22 · 2025: 42 · 2024: 40 · 2023: 27 · 2022: 19 · 2021: 5
FWCI
7.39
Type
journal article
Language
en
Open access
Locations
  • Polymer Testing (publishedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Natural Science Foundation of China
Topics
  • Physical Sciences › Engineering › Automotive Engineering › Additive Manufacturing and 3D Printing Technologies
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
  • Physical Sciences › Engineering › Mechanical Engineering › Injection Molding Process and Properties
Keywords
crystallinity control, 3D printing, shrinkage deformation, warpage, recrystallization, mechanical properties, fiber-reinforced polymer, aerospace applications, orthopedic implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›