The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Characterisation of PCL and PCL/PLA Scaffolds for Tissue Engineering
Open accessAbstract
This paper investigates the use of PCL and PCL/PLA scaffolds produced using a novel additive biomanufacturing system called BioCell Printing. PCL/PLA blends were prepared using melt blend and solvent casting techniques. Scaffolds with 0/90° architecture and 350 μm of pore size were morphologically evaluated using scanning electron microscopy and atomic force microscopy. Biological tests, using osteosarcoma cell line G-63, were performed using the Alamar Blue Assay and Alkaline Phosphatase Activity. Results show that the BioCell Printing system produces scaffolds with regular and reproducible architecture, presenting no toxicity and enhancing cell attachment and proliferation. It was also possible to observe that the addition of PLA to PCL scaffolds strongly improves the biomechanical performance of the constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
A Literature Review of Poly(Lactic Acid)
Garlotta, D. (2001) · Journal of Polymers and the Environment · doi:10.1023/a:1020200822435 · Cited by 3,707
O'Brien, J., Wilson, I., Orton, T., & Pognan, F. (2000) · European Journal of Biochemistry · doi:10.1046/j.1432-1327.2000.01606.x · Cited by 3,446
Cited by
Goyanes, A., Det-Amornrat, U., Wang, J., Basit, A. W., & Gaisford, S. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.05.034 · Cited by 490
Electrospun Polycaprolactone (PCL) Degradation: An In Vitro and In Vivo Study
Dias, J. R., Sousa, A., Augusto, A., Bártolo, P. J., & Granja, P. L. (2022) · Polymers · doi:10.3390/polym14163397 · Cited by 293
Self-citationIlyas, R., Zuhri, M., Norrrahim, M., Misenan, M., Jenol, M., Samsudin, S., Nurazzi, N., Asyraf, M., Supian, A., Bangar, S., et al. (2022) · Polymers · doi:10.3390/polym14010182 · Cited by 268
Baptista, R., & Guedes, M. (2021) · Materials Science and Engineering: C · doi:10.1016/j.msec.2020.111528 · Cited by 157
Melt electrowriting of PLA, PCL, and composite PLA/PCL scaffolds for tissue engineering application
Shahverdi, M., Seifi, S., Akbari, A., Mohammadi, K., Shamloo, A., & Movahhedy, M. R. (2022) · Scientific Reports · doi:10.1038/s41598-022-24275-6 · Cited by 154
Metadata
- Authors
- Patrício, T., Domingos, M., Gloria, A., & Bártolo, P.
- Venue
- Procedia CIRP
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 5
- Pages
- 110-114
- ISSN
- 2212-8271 (ISSN-L)
- OpenAlex
- W2054948075
- Cited by
- 196
- References
- 3
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterisation of PCL and PCL/PLA Scaffolds for Tissue Engineering. https://app.cochat.ai/papers/10.1016/j.procir.2013.01.022
- The paper
- Patrício, T., Domingos, M., Gloria, A., & Bártolo, P. (2013). Characterisation of PCL and PCL/PLA Scaffolds for Tissue Engineering. Procedia CIRP. https://doi.org/10.1016/j.procir.2013.01.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.