A Real-time PPG Quality Assessment Approach for Healthcare Internet-of-Things
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Photoplethysmography (PPG) as a non-invasive and low-cost technique plays a significant role in wearable Internet-of-Things based health monitoring systems, enabling continuous health and well-being data collection. As PPG monitoring is relatively simple, non-invasive, and convenient, it is widely used in a variety of wearable devices (e.g., smart bands, smart rings, smartphones) to acquire different vital signs such as heart rate and pulse rate variability. However, the accuracy of such vital signs highly depends on the quality of the signal and the presence of artifacts generated by other resources such as motion. This unreliable performance is unacceptable in health monitoring systems. To tackle this issue, different studies have proposed motion artifacts reduction and signal quality assessment methods. However, they merely focus on improvements in the results and signal quality. Therefore, they are unable to alleviate erroneous decision making due to invalid vital signs extracted from the unreliable PPG signals. In this paper, we propose a novel PPG quality assessment approach for IoT-based health monitoring systems, by which the reliability of the vital signs extracted from PPG quality is determined. Therefore, unreliable data can be discarded to prevent inaccurate decision making and false alarms. Exploiting a Convolutional Neural Networks (CNN) approach, a hypothesis function is created by comparing heart rate in the PPG with corresponding heart rate values extracted from ECG signal. We implement a proof-of-concept IoT-based system to evaluate the accuracy of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296 · cited 1×
“These IoT-based healthcare systems can tailor various types of wearable sensors, transmission units, and remote computing resources to deliver end-to-end health solutions to users [32, 8].”
BackgroundWearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
An IoT-Aware Architecture for Smart Healthcare Systems
Catarinucci, L., de Donno, D., Mainetti, L., Palano, L., Patrono, L., Stefanizzi, M. L., & Tarricone, L. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2417684 · Cited by 1,167 · cited 1×
“These IoT-based healthcare systems can tailor various types of wearable sensors, transmission units, and remote computing resources to deliver end-to-end health solutions to users [32, 8].”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 1×
“, infrared, red, and green) to the skin surface and acquiring the light reflection via photodetectors [40].”
BackgroundSmart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396 · cited 1×
“Ubiquitous health monitoring systems are increasingly in demand to provide reactive and proactive healthcare solutions for at-risk patients as well as mitigating medical costs, errors, and workloads [5, 30].”
BackgroundDynamic time warping and machine learning for signal quality assessment of pulsatile signals
Li, Q., & Clifford, G. D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1491 · Cited by 274
Lee, J., Matsumura, K., Yamakoshi, K.-I., Rolfe, P., Tanaka, S., & Yamakoshi, T. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609852 · Cited by 202 · cited 1×
“For example, the signal is corrupted by hand motions in wrist-based PPG sensors although the distortion depends on the signal power and the wavelength [26].”
Background
Cited by
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Cao, R., Azimi, I., Sarhaddi, F., Niela-Vilen, H., Axelin, A., Liljeberg, P., & Rahmani, A. M. (2022) · Journal of Medical Internet Research · doi:10.2196/27487 · Cited by 159
“This problem is further exacerbated by environmental noise and motion artifacts in PPG-based monitoring [19,26].”
BackgroundMethodSelf-citationPhotoplethysmogram Signal Quality Evaluation by Unsupervised Learning Approach
Roy, M. S., Gupta, R., & Sharma, K. D. (2020) · 2020 IEEE Applied Signal Processing Conference (ASPCON) · doi:10.1109/aspcon49795.2020.9276733 · Cited by 24
Mahloko, L., & Adebesin, F. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-45002-1_9 · Cited by 23
Metadata
- Authors
- Naeini, E. K., Azimi, I., Rahmani, A. M., Liljeberg, P., & Dutt, N.
- Venue
- Procedia Computer Science
- Publisher
- Elsevier BV
- Published
- 2019
- Volume
- 151
- Pages
- 551-558
- ISSN
- 1877-0509 (ISSN-L)
- OpenAlex
- W2946764178
- Cited by
- 89
- References
- 16
- FWCI
- 22.54
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.