Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion
Open accessAbstract
Reflection photoplethysmography (PPG) using 530 nm (green) wavelength light has the potential to be a superior method for monitoring heart rate (HR) during normal daily life due to its relative freedom from artifacts. However, little is known about the accuracy of pulse rate (PR) measured by 530 nm light PPG during motion. Therefore, we compared the HR measured by electrocadiography (ECG) as a reference with PR measured by 530, 645 (red), and 470 nm (blue) wavelength light PPG during baseline and while performing hand waving in 12 participants. In addition, we examined the change of signal-to-noise ratio (SNR) by motion for each of the three wavelengths used for the PPG. The results showed that the limit of agreement in Bland-Altman plots between the HR measured by ECG and PR measured by 530 nm light PPG (±0.61 bpm) was smaller than that achieved when using 645 and 470 nm light PPG (±3.20 bpm and ±2.23 bpm, respectively). The ΔSNR (the difference between baseline and task values) of 530 and 470nm light PPG was significantly smaller than ΔSNR for red light PPG. In conclusion, 530 nm light PPG could be a more suitable method than 645 and 470nm light PPG for monitoring HR in normal daily life.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ambient artifacts include light artifacts interfering with the light of the PPG sensor, weather conditions such as high humidity which increases the moisture level of the skin surface and thus its conductivity, and coverage of the device for example by a blanket which increases the temperature and thereby potentially EDA levels.
“Ambient artifacts are for example light artifacts interfering with the light of the PPG sensor43, weather conditions, such as high humidity which increases the moisture level of the skin surface and thus its conductivity44, as well as coverage of the device for example by a blanket which increases the temperature and thereby potentially EDA levels45.”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [43]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · see citing works
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9505-0 · Cited by 203 · see citing works
Reddy, K. A., George, B., & Kumar, V. J. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2009136 · Cited by 165 · see citing works
In vivo reflectance of blood and tissue as a function of light wavelength
Cui, W., Ostrander, L. E., & Lee, B. Y. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55667 · Cited by 149 · see citing works
Spīgulis, J., Gailite, L., Lihachev, A., & Erts, R. (2007) · Applied Optics · doi:10.1364/ao.46.001754 · Cited by 98 · see citing works
Han, H., & Kim, J. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.12.005 · Cited by 92 · see citing works
Matsumura, K., & Yamakoshi, T. (2013) · Behavior Research Methods · doi:10.3758/s13428-012-0312-z · Cited by 87 · see citing works
Self-citationPulsed multifrequency photoplethysmograph
Giltvedt, J., Sira, A., & Helme, P. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442745 · Cited by 47 · see citing works
Lee, J., Matsumura, K., Yamakoshi, T., Rolfe, P. J., Tanaka, N., Kim, K.-H., & Yamakoshi, K.-I. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/3/359 · Cited by 31 · see citing works
Self-citationLozano‐Nieto, A. (2008) · CRC Press eBooks · doi:10.1201/b18990-30 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · see citing works
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 567 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
An Internet-of-Things (IoT) Network System for Connected Safety and Health Monitoring Applications
Wu, F., Wu, T., & Yuce, M. R. (2018) · Sensors · doi:10.3390/s19010021 · Cited by 293 · see citing works
Jinno, H., Yokota, T., Koizumi, M., Yukita, W., Saito, M., Osaka, I., Fukuda, K., & Someya, T. (2021) · Nature Communications · doi:10.1038/s41467-021-22558-6 · Cited by 253 · see citing works
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244 · see citing works
A Rigid-Flex Wearable Health Monitoring Sensor Patch for IoT-Connected Healthcare Applications
Wu, T., Wu, F., Qiu, C., Redouté, J., & Yuce, M. R. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2977164 · Cited by 230 · see citing works
Kim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 238 · see citing works
Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200 · see citing works
Noncontact Monitoring of Blood Oxygen Saturation Using Camera and Dual-Wavelength Imaging System
Shao, D., Liu, C., Tsow, F., Yang, Y., Du, Z., Iriya, R., Yu, H., & Tao, N. J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481896 · Cited by 151 · see citing works
Liu, J., Yan, B. P., Zhang, Y., Ding, X., Su, P., & Zhao, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2874957 · Cited by 139 · see citing works
Wang, G., Atef, M., & Lian, Y. (2018) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2018.2849261 · Cited by 121 · see citing works
Franklin, D., Tzavelis, A., Lee, J. Y., Chung, H. U., Trueb, J. T., Arafa, H., Kwak, S. S., Huang, I. A., Liu, Y., Rathod, M., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01098-y · Cited by 119 · see citing works
Self-citationScardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 120 · see citing works
A Multi-Sensor and Parallel Processing SoC for Miniaturized Medical Instrumentation
Schönle, P., Glaser, F., Burger, T., Rovere, G., Luca Benini, C., & Huang, Q. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2815653 · Cited by 98 · see citing works
A Real-time PPG Quality Assessment Approach for Healthcare Internet-of-Things
Naeini, E. K., Azimi, I., Rahmani, A. M., Liljeberg, P., & Dutt, N. D. (2019) · Procedia Computer Science · doi:10.1016/j.procs.2019.04.074 · Cited by 90 · see citing works
Data quality evaluation in wearable monitoring
Böttcher, S., Vieluf, S., Bruno, E., Joseph, B., Epitashvili, N., Biondi, A., Zabler, N., Glasstetter, M., Dümpelmann, M., Van Laerhoven, K., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-25949-x · Cited by 91 · see citing works
iPhys: An Open Non-Contact Imaging-Based Physiological Measurement Toolbox
McDuff, D., & Blackford, E. B. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857012 · Cited by 84 · see citing works
Stone, J. D., Rentz, L. E., Forsey, J. D., Ramadan, J. H., Markwald, R. R., Finomore, V. S., Galster, S. M., Rezai, A. R., & Hagen, J. A. (2020) · Nature and Science of Sleep · doi:10.2147/nss.s270705 · Cited by 85 · see citing works
A Review of Skin-Wearable Sensors for Non-Invasive Health Monitoring Applications
Mao, P., Li, H., & Yu, Z. (2023) · Sensors · doi:10.3390/s23073673 · Cited by 85 · see citing works
Driver Drowsiness Detection Using Multi-Channel Second Order Blind Identifications
Zhang, C., Wu, X., Zheng, X., & Yu, S. (2019) · IEEE Access · doi:10.1109/access.2019.2891971 · Cited by 81 · see citing works
An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications
Galli, A., Montree, R. J. H., Que, S., Peri, E., & Vullings, R. (2022) · Sensors · doi:10.3390/s22114035 · Cited by 79 · see citing works
Zhou, Z.-B., Cui, T., Li, D., Jian, J., Li, Z., Ji, S., Li, X., Xu, J., Liu, H., Yang, Y., et al. (2023) · Materials · doi:10.3390/ma16062133 · Cited by 81 · see citing works
Matsumura, K., Rolfe, P. J., Lee, J., & Yamakoshi, T. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091205 · Cited by 72 · see citing works
Self-citationSmart-watch-programmed green-light-operated percutaneous control of therapeutic transgenes
Mansouri, M., Hussherr, M., Strittmatter, T., Buchmann, P., Xue, S., Camenisch, G., & Fussenegger, M. (2021) · Nature Communications · doi:10.1038/s41467-021-23572-4 · Cited by 71 · see citing works
Blood Glucose Level Regression for Smartphone PPG Signals Using Machine Learning
Islam, T. T., Ahmed, M. S., Hassanuzzaman, M., Amir, S. A. B., & Rahman, T. (2021) · Applied Sciences · doi:10.3390/app11020618 · Cited by 72 · see citing works
Lee, H., Chung, H., Ko, H., & Lee, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2801385 · Cited by 61 · see citing works
Self-citationValidation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59 · see citing works
Alzahrani, A., Hu, S., Azorin-Peris, V., Barrett, L. A., Esliger, D., Hayes, M., Akbare, S., Achart, J., & Kuoch, S. (2015) · Sensors · doi:10.3390/s151025681 · Cited by 56 · see citing works
Flexible and Printed PPG Sensors for Estimation of Drowsiness
Ryu, G., You, J., Kostianovskii, V., Lee, E.-B., Kim, Y., Park, C., & Noh, Y. (2018) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2018.2833477 · Cited by 56 · see citing works
Image Enhancement for Remote Photoplethysmography in a Low-Light Environment
Lin, X., Chen, W., Zhao, C., Wu, X., & Wang, J. (2020) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg47880.2020.00076 · Cited by 55 · see citing works
Harju, J., Tarniceriu, A., Parák, J., Vehkaoja, A. T., Yli‐Hankala, A., & Korhonen, I. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac9a9 · Cited by 55 · see citing works
Fall prediction using behavioural modelling from sensor data in smart homes
Forbes, G., Massie, S., & Craw, S. (2019) · Artificial Intelligence Review · doi:10.1007/s10462-019-09687-7 · Cited by 55 · see citing works
Blood pressure measurement using only a smartphone
Frey, L., Menon, C., & Elgendi, M. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00629-2 · Cited by 55 · see citing works
Prabha, A., Yadav, J., Rani, A., & Singh, V. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103876 · Cited by 56 · see citing works
Li, J., Chu, H., Chen, Z., Yiu, C. K., Qu, Q., Li, Z.-Y., & Yu, X. (2024) · ACS Nano · doi:10.1021/acsnano.4c04291 · Cited by 50 · see citing works
Photoplethysmogram at green light: Where does chaos arise from?
Sviridova, N., Zhao, T., Aihara, K., Nakamura, K., & Nakano, A. (2018) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2018.09.016 · Cited by 52 · see citing works
Morelli, D., Bartoloni, L., Colombo, M., Plans, D., & Clifton, D. A. (2017) · Healthcare Technology Letters · doi:10.1049/htl.2017.0039 · Cited by 51 · see citing works
Wei, B., He, X., Zhang, C., & Wu, X. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0300-0 · Cited by 50 · see citing works
Convertino, V. A., Schauer, S. G., Weitzel, E. K., Cardin, S., Stackle, M. E., Talley, M. J., Sawka, M. N., & Inan, O. T. (2020) · Sensors · doi:10.3390/s20226413 · Cited by 49 · see citing works
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49 · see citing works
Tautan, A.-M., Young, A., Wentink, E., & Wieringa, F. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319795 · Cited by 47 · see citing works
Rodrigues, L. M., Rocha, C., Ferreira, H. A., & Silva, H. (2019) · Scientific Reports · doi:10.1038/s41598-019-53213-2 · Cited by 45 · see citing works
Rentz, L. E., Ulman, H. K., & Galster, S. M. (2021) · Sensors · doi:10.3390/s21155071 · Cited by 46 · see citing works
Automated loss of pulse detection on a consumer smartwatch
Shah, K., Wang, A., Chen, Y., Munjal, J., Chhabra, S., Stange, A., Wei, E., Phan, T., Giest, T., Hawkins, B., et al. (2025) · Nature · doi:10.1038/s41586-025-08810-9 · Cited by 44 · see citing works
Gnacek, M., Broulidakis, M. J., Mavridou, I. I., Fatoorechi, M., Seiss, E., Κωστούλας, Θ., Balaguer‐Ballester, E., Kiprijanovska, I., Rosten, C., & Nduka, C. C. (2022) · Frontiers in Virtual Reality · doi:10.3389/frvir.2022.781218 · Cited by 44 · see citing works
Non-contact remote estimation of cardiovascular parameters
Fan, Q., & Li, K. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.09.022 · Cited by 41 · see citing works
Using photoplethysmography in heart rate monitoring of patients with epilepsy
van Andel, J., Ungureanu, C., Aarts, R., Leijten, F., & Arends, J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.02.018 · Cited by 39 · see citing works
Estimation of HRV and SpO2 from wrist-worn commercial sensors for clinical settings
Jarchi, D., Salvi, D., Velardo, C., Mahdi, A., Tarassenko, L., & Clifton, D. A. (2018) · 2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN) · doi:10.1109/bsn.2018.8329679 · Cited by 38 · see citing works
The Importance of Data Quality Control in Using Fitbit Device Data From the Research Program
Lederer, L. E., Breton, A., Jeong, H., Master, H., Roghanizad, A. R., & Dunn, J. (2023) · JMIR mhealth and uhealth · doi:10.2196/45103 · Cited by 41 · see citing works
Wang, Y., Liu, Z., & Ma, S. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa996d · Cited by 36 · see citing works
Zenko, J., Kos, M., & Kramberger, I. (2016) · International Conference on Systems, Signals and Image Processing · doi:10.1109/iwssip.2016.7502766 · Cited by 35 · see citing works
Video pulse rate variability analysis in stationary and motion conditions
Rodríguez, A., & Ramos-Castro, J. J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0437-0 · Cited by 34 · see citing works
A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods
Desquins, T., Bousefsaf, F., Pruski, A., & Maaoui, C. (2022) · Applied Sciences · doi:10.3390/app12199582 · Cited by 33 · see citing works
Accuracy and Reliability of Pulse O2 Saturation Measured by a Wrist-worn Oximeter
Hermand, É., Coll, C., Richalet, J., & Lhuissier, F. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1337-2790 · Cited by 31 · see citing works
MW-PPG Sensor: An on-Chip Spectrometer Approach
Chang, C.-C., Wu, C.-T., Choi, B. I., & Fang, T.-J. (2019) · Sensors · doi:10.3390/s19173698 · Cited by 30 · see citing works
Simultaneous detection of blink and heart rate using multi-channel ICA from smart phone videos
Zhang, C., Wu, X., Zhang, L., He, X., & Lv, Z. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.11.022 · Cited by 30 · see citing works
Analysis and improvement of non-contact SpO2 extraction using an RGB webcam
Wei, B., Wu, X., Zhang, C., & Lv, Z. (2021) · Biomedical Optics Express · doi:10.1364/boe.423508 · Cited by 30 · see citing works
Guede-Fernández, F., Ferrer-Mileo, V., Ramos-Castro, J. J., Fernández-Chimeno, M., & Garcia-Gonzalez, M. A. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320085 · Cited by 30 · see citing works
Using imaging photoplethysmography for heart rate estimation in non-human primates
Михайлович, У. А., Moeller, S., Kagan, I., Gail, A., Treue, S., & Wolf, F. (2018) · PLoS ONE · doi:10.1371/journal.pone.0202581 · Cited by 29 · see citing works
Wang, Y., Liu, Z., Yang, J., & Ma, S. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0389-9 · Cited by 27 · see citing works
Wearables in Cardiovascular Disease
Kumar, S., Victoria‐Castro, A. M., Melchinger, H. C., O’Connor, K. D., Psotka, M. A., Desai, N. R., Ahmad, T., & Wilson, F. P. (2022) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-022-10314-0 · Cited by 27 · see citing works
Yamakoshi, Y., Matsumura, K., Yamakoshi, T., Lee, J., Rolfe, P. J., Kato, Y., Shimizu, K., & Yamakoshi, K.-I. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.6.067001 · Cited by 27 · see citing works
Self-citationMatsumura, K., Toda, S., & Kato, Y. (2020) · IEEE Access · doi:10.1109/access.2020.2990438 · Cited by 27 · see citing works
Self-citationImaging PPG for In Vivo Human Tissue Perfusion Assessment during Surgery
Lai, M., van der Stel, S. D., Groen, H. C., van Gastel, M., Kuhlmann, K. F. D., Ruers, T. J. M., & Hendriks, B. H. W. (2022) · Journal of Imaging · doi:10.3390/jimaging8040094 · Cited by 25 · see citing works
Uncertainties in the Analysis of Heart Rate Variability: A Systematic Review
Lü, L., Zhu, T., Morelli, D., Creagh, A. P., Liu, Z., Yang, J., Liu, F., Zhang, Y., & Clifton, D. A. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3271595 · Cited by 28 · see citing works
Wearable Motion Tolerant PPG Sensor for Instant Heart Rate in Daily Activity
Ishikawa, T., Hyodo, Y., Miyashita, K., Yoshifuji, K., Komoriya, Y., & Imai, Y. (2017) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0006109901260133 · Cited by 24 · see citing works
Alharbi, S., Hu, S., Mulvaney, D. J., Barrett, L. A., Yan, L., Blanos, P., Elsahar, Y., & Adema, S. (2018) · Sensors · doi:10.3390/s19010118 · Cited by 24 · see citing works
Park, P., Lee, W., & Cho, S. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3315297 · Cited by 23 · see citing works
Shooshtari, L., Ghods, S., Mohammadpour, R., Esfandiar, A., & zad, A. I. (2022) · Scientific Reports · doi:10.1038/s41598-022-11327-0 · Cited by 22 · see citing works
Non-Contact Reflectance Photoplethysmography: Progress, Limitations, and Myths
Špetlík, R., Čech, J., & Matas, J. (2018) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2018.00111 · Cited by 22 · see citing works
OpenEarable 2.0: Open-Source Earphone Platform for Physiological Ear Sensing
Röddiger, T., Küttner, M., Lepold, P., King, T., Moschina, D., Bagge, O., Paradiso, J. A., Clarke, C., & Beigl, M. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3712069 · Cited by 21 · see citing works
Reynolds, J., Ahmmed, P., & Bozkurt, A. Y. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2923153 · Cited by 19 · see citing works
A novel temporal adaptive fuzzy neural network for facial feature based fatigue assessment
Zhang, Z., Wang, H., You, Q., Chen, L., & Ning, H. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.124124 · Cited by 19 · see citing works
Health analysis of bicycle rider and security of bicycle using IoT
Nath, S., Sinha, S., Gladence, L. M., BevishJinila, Y., & Rajalakshmi, V. (2017) · doi:10.1109/iccsp.2017.8286475 · Cited by 18 · see citing works
Carek, A. M., Jung, H., & Inan, O. T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2960063 · Cited by 18 · see citing works
Sinichi, M., Gevonden, M. J., & Krabbendam, L. (2025) · Psychophysiology · doi:10.1111/psyp.70004 · Cited by 22 · see citing works
Yamakoshi, T., Lee, J., Matsumura, K., Yamakoshi, Y., Rolfe, P. J., Kiyohara, D., & Yamakoshi, K.-I. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143506 · Cited by 17 · see citing works
Self-citationPont, M. P. D., & Marques, J. L. B. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2963508 · Cited by 17 · see citing works
Evaluating RGB channels in remote photoplethysmography: a comparative study with contact-based PPG
Ontiveros, R. C., Elgendi, M., Missale, G., & Menon, C. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1296277 · Cited by 16 · see citing works
Bauer, M., Bräuer, C., Schuldt, J., Niemann, M., & Krömker, H. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-94619-1_4 · Cited by 16 · see citing works
iPhysioMeter: A Smartphone Photoplethysmograph for Measuring Various Physiological Indices
Matsumura, K., Rolfe, P. J., & Yamakoshi, T. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-2172-0_21 · Cited by 17 · see citing works
Self-citationWearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation
Cheung, M. Y., Sabharwal, A., Coté, G. L., & Veeraraghavan, A. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3434344 · Cited by 16 · see citing works
Biometrie authentication using hand movement information from wrist-worn PPG sensors
Ohtsuki, T. O., & Hiroto, K. (2016) · IEEE International Symposium on Personal, Indoor and Mobile Radio Communications (PIMRC) · doi:10.1109/pimrc.2016.7794969 · Cited by 15 · see citing works
Giovanni, E. D., Srinivasan Murali, A., Rincón, F. J., & Atienza, D. (2016) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2016.101 · Cited by 15 · see citing works
Noncontact measurement of emotional and physiological changes in heart rate from a webcam
Madan, C. R., Harrison, T., & Mathewson, K. E. (2017) · Psychophysiology · doi:10.1111/psyp.13005 · Cited by 15 · see citing works
Pretty, E. J., Guarese, R., Dziego, C. A., Fayek, H. M., & Zambetta, F. (2024) · IEEE Transactions on Games · doi:10.1109/tg.2024.3406723 · Cited by 14 · see citing works
Low-cost portable heart rate monitoring based on photoplethysmography and decision tree
Tunggal, T. P., Latif, A., & Iswanto, I. (2016) · AIP conference proceedings · doi:10.1063/1.4958522 · Cited by 14 · see citing works
Blažek, V., Blanik, N., Blazek, C., Paul, M., Pereira, C. B., Köny, M., Venema, B., & Leonhardt, S. K. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001388 · Cited by 14 · see citing works
Remote measurement of heart rate from facial video in different scenarios
Zheng, X., Zhang, C., Chen, H., Zhang, Y., & Yang, X. (2021) · Measurement · doi:10.1016/j.measurement.2021.110243 · Cited by 14 · see citing works
Hayirlioglu, Y. Z., & Semiz, B. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3403846 · Cited by 13 · see citing works
Preclinical Evaluation of a Wearable Wristband With Compressed-Sensing Based Photoplethysmography
Ahmmed, P., Garceau, E. L., Latif, T., Brewer, A., Dieffenderfer, J. P., Valero-Sarmiento, J. M., Pamula, V. R., Helleputte, N. V., Hoof, C. A. V., Verhelst, M., et al. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3513462 · Cited by 14 · see citing works
Embedded system in handheld water turbidity meter for smallholders
Putra, B. T. W., Rocelline, L. A., & Syahputra, W. N. H. (2022) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2022.104603 · Cited by 13 · see citing works
Blanos, P., Hu, S., Mulvaney, D. J., & Alharbi, S. (2018) · Design and Quality for Biomedical Technologies · doi:10.1117/12.2287854 · Cited by 13 · see citing works
Ahmmed, P., Dieffenderfer, J. P., Valero-Sarmiento, J. M., Pamula, V. R., Helleputte, N. V., Hoof, C. A. V., Verhelst, M., & Bozkurt, A. Y. (2019) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2019.8771074 · Cited by 13 · see citing works
Ceugniez, M., Devanne, H., & Hermand, É. (2024) · JMIR mhealth and uhealth · doi:10.2196/54871 · Cited by 11 · see citing works
Low-cost wearable bluetooth sensor for epileptic episodes detection
Ramirez-Alaminos, J. M., Sendra, S., Lloret, J., & Navarro‐Ortiz, J. (2017) · International Conference on Communications · doi:10.1109/icc.2017.7997413 · Cited by 12 · see citing works
Watson, A., Kendell, C., Lingamoorthy, A., Lee, I., & Weimer, J. E. (2022) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3569502 · Cited by 12 · see citing works
Bioelectronic devices for light-based diagnostics and therapies
Kim, H., Sritandi, W., Xiong, Z., & Ho, J. S. (2023) · Biophysics Reviews · doi:10.1063/5.0102811 · Cited by 12 · see citing works
Wearable edge machine learning with synthetic photoplethysmograms
Sirkiä, J., Panula, T., & Kaisti, M. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.121523 · Cited by 12 · see citing works
- Authors
- Lee, J., Matsumura, K., Yamakoshi, K.-I., Rolfe, P., Tanaka, S., & Yamakoshi, T.
- Affiliations
- Kanazawa University (JP)
- Harbin Institute of Technology (CN)
- Venue
- 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2013-07
- Volume
- 2013
- Issue
- 6609852
- Pages
- 1724-1727
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W1988770599
- Cited by
- 202
- References
- 12
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 23 · 2023: 26 · 2022: 19 · 2021: 16 · 2020: 14 · 2019: 19 · 2018: 23 · 2017: 19 · 2016: 11 · 2015: 15 · 2014: 5
- FWCI
- 20.48
- Type
- conference paper
- Language
- en
- Open access
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
- Kanazawa University Repository for Academic Resources (DSpace) (Kanazawa University) (submittedVersion, cc-by-nc-nd)
- Funders
- Kissei
- Japan Society for the Promotion of Science (24650443)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- heart rate monitoring, motion artifacts, signal-to-noise ratio, hand waving, ECG comparison, wearable sensors, non-contact vital sign monitoring
- MeSH terms
- Adult, Heart Rate, Humans, Light, Male, Movement, Photoplethysmography, Monitoring, Ambulatory, Young Adult, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review