CoChat

Fully Printed Flexible Humidity Sensor

Open access
Reddy, A.S.G., Narakathu, B.B., Atashbar, M.Z., Rebros, M., Rebrosova, E., Joyce, M.K. · 2011 · Procedia Engineering
Cited by 129

The DOI matches its Crossref record.

Abstract

A humidity sensor that employs interdigitated capacitors (IDC) printed with silver (Ag) nanoparticle based ink on a flexible poly ethylene terephthalate (PET) substrate was successfully fabricated using gravure printing process. Thicknesses of 1 μm and 500 μm of a humidity sensitive polymer poly (2-hydroxyethyl methacrylate) (pHEMA) was deposited on the IDCs by means of gravure printing. The capacitive response of the sensor towards relative humidity (RH) was measured in the range of 30% RH to 80% RH; the maximum percentage change in capacitance was 172% at 80% RH when compared to base capacitance at 30% RH. The humidity response of the printed sensor revealed a very high stability with a maximum error of 0.6% and 0.8% from the average value at 40% RH and 60% RH, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.proeng.2011.12.030

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Reddy, A. S. G., Narakathu, B. B., Atashbar, M. Z., Rebros, M., Rebrosova, E., & Joyce, M. K.
Venue
Procedia Engineering
Publisher
Elsevier BV
Published
2011
Volume
25
Pages
120-123
ISSN
1877-7058 (ISSN-L)
OpenAlex
W2504642052
Cited by
129
References
0
FWCI
7.39
Type
conference paper
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.