Monitoring tumor motion by real time 2D/3D registration during radiotherapy
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE: In this paper, we investigate the possibility to use X-ray based real time 2D/3D registration for non-invasive tumor motion monitoring during radiotherapy. MATERIALS AND METHODS: The 2D/3D registration scheme is implemented using general purpose computation on graphics hardware (GPGPU) programming techniques and several algorithmic refinements in the registration process. Validation is conducted off-line using a phantom and five clinical patient data sets. The registration is performed on a region of interest (ROI) centered around the planned target volume (PTV). RESULTS: The phantom motion is measured with an rms error of 2.56 mm. For the patient data sets, a sinusoidal movement that clearly correlates to the breathing cycle is shown. Videos show a good match between X-ray and digitally reconstructed radiographs (DRR) displacement. Mean registration time is 0.5 s. CONCLUSIONS: We have demonstrated that real-time organ motion monitoring using image based markerless registration is feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“We used the Normalized Mutual Information metric, where a statistical dependence between the distributions of intensities is used to achieve registration [22].”
MethodA Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746 · cited 1×
“Intensity DRR-based methods were the first and the most intuitive solution proposed to solve the 2D/3D registration problem [19].”
MethodGendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Self-citation
Cited by
A CNN Regression Approach for Real-Time 2D/3D Registration
Miao, S., Wang, Z. J., & Liao, R. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2521800 · Cited by 514
“We evaluated three popular similarity measures, MI, Cross Correlation (CC) and GC, which have also been reported to be effective in recent literature [3], [4], [12].”
MethodDilated FCN for Multi-Agent 2D/3D Medical Image Registration
Miao, S., Piat, S., Fischer, P., Tuysuzoglu, A., Mewes, P., Mansi, T., & Liao, R. (2018) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v32i1.11576 · Cited by 113
Real-time 2D/3D registration via CNN regression
Miao, S., Wang, Z. J., Zheng, Y., & Liao, R. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493536 · Cited by 101
Markerless Pancreatic Tumor Target Localization Enabled By Deep Learning
Zhao, W., Shen, L., Han, B., Yang, Y., Cheng, K., Toesca, D. A. S., Koong, A. C., Chang, D. T., & Xing, L. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.05.071 · Cited by 88
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 89
“Applications of 3D–2D registration include improving target localization accuracy in radiation therapy (Gendrin et al 2012), real-time kinematic analysis of skeletal movements using fluoroscopy (Xin et al 2013, Zhu et al 2012, Jerbi et al 2012), guidance of various surgical interventions such as…”
Method
Metadata
- Authors
- Gendrin, C., Furtado, H., Weber, C., Bloch, C., Figl, M., Pawiro, S. A., Bergmann, H., Stock, M., Fichtinger, G., Georg, D., & Birkfellner, W.
- Venue
- Radiotherapy and Oncology
- Publisher
- Elsevier BV
- Published
- 2012-02
- Volume
- 102
- Issue
- 2
- Pages
- 274-280
- ISSN
- 0167-8140 (ISSN-L)
- OpenAlex
- W2011095615
- Cited by
- 87
- References
- 3
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.