Reproducibility of NIRS assessment of muscle oxidative capacity in smokers with and without COPD
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Low muscle oxidative capacity contributes to exercise intolerance in chronic obstructive pulmonary disease (COPD). Near-infrared spectroscopy (NIRS) allows non-invasive determination of the muscle oxygen consumption (mV˙O2) recovery rate constant (k), which is proportional to oxidative capacity assuming two conditions are met: 1) exercise intensity is sufficient to fully-activate mitochondrial oxidative enzymes; 2) sufficient O2 availability. We aimed to determine reproducibility (coefficient of variation, CV; intraclass correlation coefficient, ICC) of NIRS k assessment in the gastrocnemius of 64 participants with (FEV1 64±23%predicted) or without COPD (FEV1 98±14%predicted). 10–15s dynamic contractions preceded 6min of intermittent arterial occlusions (5–10s each, ~250mmHg) for k measurement. k was lower (P<0.05) in COPD (1.43±0.4min−1; CV=9.8±5.9%, ICC=0.88) than controls (1.74±0.69min−1; CV=9.9±8.4%; ICC=0.93). Poor k reproducibility was more common when post-contraction mV˙O2 and deoxygenation were low, suggesting insufficient exercise intensity for mitochondrial activation and/or the NIRS signal contained little light reflected from active muscle. The NIRS assessment was well tolerated and reproducible for muscle dysfunction evaluation in COPD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
Genetic epidemiology of copd (copdgene) study design
Regan, E. A., Hokanson, J. E., Murphy, J. R., Make, B., Lynch, D. A., Beaty, T. H., Curran-Everett, D., Silverman, E. K., & Crapo, J. D. (2011) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412550903499522 · Cited by 1,313
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
WHITTOM, F., JOBIN, J., SIMARD, P.-M., LEBLANC, P., SIMARD, C., BERNARD, S., BELLEAU, R., & MALTAIS, F. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199810000-00001 · Cited by 447
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Ryan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
The Mitochondrial Phenotype of Peripheral Muscle in Chronic Obstructive Pulmonary Disease
Picard, M., Godin, R., Sinnreich, M., Baril, J., Bourbeau, J., Perrault, H., Taivassalo, T., & Burelle, Y. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200807-1005oc · Cited by 95
Meyer, A., Zoll, J., Charles, A. L., Charloux, A., de Blay, F., Diemunsch, P., Sibilia, J., Piquard, F., & Geny, B. (2013) · Experimental Physiology · doi:10.1113/expphysiol.2012.069468 · Cited by 90
Southern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2013-0347 · Cited by 80
Factors Limiting Exercise Tolerance in Chronic Lung Diseases
Vogiatzis, I., & Zakynthinos, S. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110015 · Cited by 77
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
Urianstad, T., Villanova, S., Odden, I., Hansen, J., Mølmen, K. S., Porcelli, S., Rønnestad, B. R., & Cardinale, D. A. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00469.2024 · Cited by 19
Adami, A., Hobbs, B. D., McDonald, M.-L. N., Casaburi, R., Rossiter, H. B., & for the COPDGene Investigators (2018) · Physiological Genomics · doi:10.1152/physiolgenomics.00140.2017 · Cited by 8
Self-citationVenckunas, T., Satas, A., Brazaitis, M., Eimantas, N., Sipaviciene, S., & Kamandulis, S. (2024) · Sensors · doi:10.3390/s24072277 · Cited by 6
Metadata
- Authors
- Adami, A., Cao, R., Porszasz, J., Casaburi, R., & Rossiter, H. B.
- Venue
- Respiratory Physiology & Neurobiology
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 235
- Pages
- 18-26
- ISSN
- 1569-9048 (ISSN-L)
- OpenAlex
- W2522562163
- Cited by
- 63
- References
- 11
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of NIRS assessment of muscle oxidative capacity in smokers with and without COPD. https://app.cochat.ai/papers/10.1016/j.resp.2016.09.008
- The paper
- Adami, A., Cao, R., Porszasz, J., Casaburi, R., & Rossiter, H. B. (2017). Reproducibility of NIRS assessment of muscle oxidative capacity in smokers with and without COPD. Respiratory Physiology & Neurobiology. https://doi.org/10.1016/j.resp.2016.09.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.