Validation of a Portuguese version of the STOP-Bang questionnaire as a screening tool for obstructive sleep apnea: Analysis in a sleep clinic
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Screening methods have become increasingly important owing to the growing number of patients suspected of obstructive sleep apnea (OSA) being referred for sleep consultation. The STOP-Bang questionnaire has been validated as a screening tool for OSA in surgical patients. OBJECTIVES: To evaluate the performance of a Portuguese version of the STOP-Bang questionnaire for the diagnosis of OSA in a sleep clinic. METHODS: Prospectively, for 2 months, all patients referred to our clinic for clinical evaluation completed a translated version of the STOP-Bang questionnaire in Portuguese and underwent a sleep study. RESULTS: We observed 216 patients and 215 (99.5%) were included. Age was 53.63±13.10 years, 63.3% were male patients, neck circumference was 40.4±44.11 cm and BMI was 29.41 [26.85; 33.06] kg/m(2). OSA was present in 78% of the patients, of whom, 33% had moderate and 37% had severe OSA. A STOP-Bang score ≥3 had a sensitivity and positive predictive value (PPV) for OSA of 93.4% and 86.6%, respectively. Each increase in the STOP-Bang score was associated with an increase in the probability of OSA and severe OSA; reaching a 95% OSA probability, for a score of 6, and a 73% severe OSA probability, for a score of 8. A score of 3 and 2 had a negative predictive value for moderate/severe OSA of 85.3% and 91.7%, respectively. CONCLUSIONS: The STOP-Bang questionnaire showed high sensitivity and PPV for OSA with the probability of severe OSA steadily increasing, the higher the scores. Furthermore, a low score showed high predictive value for the exclusion of moderate/severe OSA. The STOP-Bang questionnaire can be a powerful tool for stratifying patients in the diagnosis of OSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using the Berlin Questionnaire To Identify Patients at Risk for the Sleep Apnea Syndrome
Netzer, N. C., Stoohs, R. A., Netzer, C. M., Clark, K., & Strohl, K. P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00002 · Cited by 2,973
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355
Sleep Disordered Breathing and Mortality: Eighteen-Year Follow-up of the Wisconsin Sleep Cohort
(2008) · Sleep · doi:10.5665/sleep/31.8.1071 · Cited by 1,853
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
High STOP-Bang score indicates a high probability of obstructive sleep apnoea
Chung, F., Subramanyam, R., Liao, P., Sasaki, E., Shapiro, C., & Sun, Y. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes022 · Cited by 988
McNicholas, W. T., Bonsignore, M. R., & the Management Committee of EU COST ACTION B26 (2007) · European Respiratory Journal · doi:10.1183/09031936.00027406 · Cited by 911
Sleep Apnea as an Independent Risk Factor for All-Cause Mortality: The Busselton Health Study
(2008) · Sleep · doi:10.5665/sleep/31.8.1079 · Cited by 889
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Rosen, C. L., Auckley, D., Benca, R., Foldvary-Schaefer, N., Iber, C., Kapur, V., Rueschman, M., Zee, P., & Redline, S. (2012) · Sleep · doi:10.5665/sleep.1870 · Cited by 367
A Meta-analysis of Clinical Screening Tests for Obstructive Sleep Apnea
Ramachandran, S. K., & Josephs, L. A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819c47b6 · Cited by 297
Cited by
Nagappa, M., Liao, P., Wong, J., Auckley, D., Ramachandran, S. K., Memtsoudis, S., Mokhlesi, B., & Chung, F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0143697 · Cited by 684
“Data from four studies (n = 1980)[21,27,29,30] from the sleep clinic population, and two (n = 827)[18,19] from the surgical population were pooled separately (Table 4 & Fig 2).”
BackgroundMethodResultInfluentialChiu, H.-Y., Chen, P.-Y., Chuang, L.-P., Chen, N.-H., Tu, Y.-K., Hsieh, Y.-J., Wang, Y.-C., & Guilleminault, C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.10.004 · Cited by 650
Chung, F., Memtsoudis, S. G., Ramachandran, S. K., Nagappa, M., Opperer, M., Cozowicz, C., Patrawala, S., Lam, D., Kumar, A., Joshi, G. P., et al. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001416 · Cited by 360
Metadata
- Authors
- Reis, R., Teixeira, F., Martins, V., Sousa, L., Batata, L., Santos, C., & Moutinho, J.
- Venue
- Revista Portuguesa de Pneumologia (English Edition)
- Publisher
- Informa UK Limited
- Published
- 2015-03-30
- Volume
- 21
- Issue
- 2
- Pages
- 61-68
- ISSN
- 0873-2159 (ISSN-L)
- 2173-5115
- OpenAlex
- W2101073692
- Cited by
- 50
- References
- 12
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of a Portuguese version of the STOP-Bang questionnaire as a screening tool for obstructive sleep apnea: Analysis in a sleep clinic. https://app.cochat.ai/papers/10.1016/j.rppnen.2014.04.009
- The paper
- Reis, R., Teixeira, F., Martins, V., Sousa, L., Batata, L., Santos, C., & Moutinho, J. (2015). Validation of a Portuguese version of the STOP-Bang questionnaire as a screening tool for obstructive sleep apnea: Analysis in a sleep clinic. Revista Portuguesa de Pneumologia (English Edition). https://doi.org/10.1016/j.rppnen.2014.04.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.