Development of printed and flexible dry ECG electrodes
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Printed, flexible and wearable dry electrodes for monitoring electrocardiogram (ECG) signals, without any skin preparation and use of wet gel, has been developed. Silver (Ag) flake ink was screen printed on a flexible polyethylene terephthalate (PET) substrate to fabricate the dry ECG electrode. Multi-walled carbon nanotube (MWCNT)/polydimethylsiloxane (PDMS) composite, as a conductive polymer, was then deposited on the printed Ag electrode by using a bar coating technique. The performance of the printed electrodes was investigated by testing the MWCNT/PDMS composite conductivity and measuring the electrode-skin impedance for electrode radii varying from 8 mm to 16 mm. It was observed that the dry ECG electrode, with the largest area, demonstrated better performance, in terms of MWCNT/PDMS composite conductivity, ECG signal intensity and correlation when compared to a commercial wet silver/silver chloride (Ag/AgCl) electrode. In addition, the capability of the dry ECG electrodes for monitoring ECG signals in both the relaxed sitting position and while the subject is in motion, was also investigated and the results were compared with a wet Ag/AgCl ECG electrode (T716). While the subject is in motion, the printed dry electrodes were less noisy and were able to better identify the typical ECG characteristics in the signals due to its better conformal contact at the electrode-skin interface. The results obtained demonstrated the feasibility of employing conventional screen printing process for the development of flexible dry ECG electrodes for applications in the biomedical industry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut
Kalantar-Zadeh, K., Berean, K. J., Ha, N., Chrimes, A. F., Xu, K., Grando, D., Ou, J. Z., Pillai, N., Campbell, J. L., Brkljača, R., et al. (2018) · Nature Electronics · doi:10.1038/s41928-017-0004-x · Cited by 342
Wearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231
Cited by
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
Metadata
- Authors
- Chlaihawi, A. A., Narakathu, B. B., Emamian, S., Bazuin, B. J., & Atashbar, M. Z.
- Venue
- Sensing and Bio-Sensing Research
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 20
- Pages
- 9-15
- ISSN
- 2214-1804 (ISSN-L)
- OpenAlex
- W2800997629
- Cited by
- 193
- References
- 3
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of printed and flexible dry ECG electrodes. https://app.cochat.ai/papers/10.1016/j.sbsr.2018.05.001
- The paper
- Chlaihawi, A. A., Narakathu, B. B., Emamian, S., Bazuin, B. J., & Atashbar, M. Z. (2018). Development of printed and flexible dry ECG electrodes. Sensing and Bio-Sensing Research. https://doi.org/10.1016/j.sbsr.2018.05.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.