CoChat

Analyses of per- and polyfluoroalkyl substances (PFAS) through the urban water cycle: Toward achieving an integrated analytical workflow across aqueous, solid, and gaseous matrices in water and wastewater treatment

Open access
Winchell, Lloyd J., Wells, Martha J.M., Ross, John J., Fonoll, Xavier, Norton, John W., Kuplicki, Stephen, Khan, Majid, Bell, Katherine Y. · 2021 · Science of The Total Environment
Cited by 98

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

Our knowledge of PFAS fate and transport in the urban water cycle between water treatment plants (WTPs) and wastewater treatment plants (WWTPs) is dependent upon analytical methodology. To conduct a mass balance of PFAS through these engineered systems, environmental analytical chemistry must be leveraged to quantify PFAS in the various media that cycle through these facilities. Although mass balances have been attempted across various unit treatment processes for a small selection of PFAS in WTPs and WWTPs, system-wide mass balances are a daunting challenge that have not been achieved to date. The continued existence of legacy PFAS and the constantly moving target of newly emerging commercial PFAS and transformation products (TPs), in addition to complications resulting from bias-free collection of uncontaminated samples for PFAS in the parts-per-trillion (ppt) range, complicate a mass balance. Further compounding a mass balance is the diverse universe of PFAS which consists of polar/nonpolar, nonvolatile/semi-volatile/volatile, and neutral/anionic/cationic/zwitterionic chemicals. The physicochemical properties of these chemicals, and the media in which they exist, drive the selection of appropriate analytical procedures to provide accurate and precise quantification of these compounds. The current state of analytical science for PFAS is development of methods specific for subgroups of PFAS families in limited matrices. Here, approaches to integrate analytical workflows across types of PFAS and media are proposed. In this evaluation, multi-platform targeted, suspect/non-targeted, and surrogate screening methods combining promulgated standardized methods and emerging procedures are presented. Synthesis of a comprehensive analytical workflow that aspires to achieve a mass balance of PFAS across the gaseous, solid, and aqueous matrices encountered in WTPs and WWTPs is proposed. Finally, research data gaps and future research needs are also discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.scitotenv.2021.145257

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 98

Metadata

Authors
Winchell, L. J., Wells, M. J. M., Ross, J. J., Fonoll, X., Norton, J. W., Kuplicki, S., Khan, M., & Bell, K. Y.
Venue
Science of The Total Environment
Publisher
Elsevier BV
Published
2021-06
Volume
774
Pages
145257
ISSN
0048-9697 (ISSN-L)
OpenAlex
W3123465391
Cited by
98
References
42
FWCI
5.00
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analyses of per- and polyfluoroalkyl substances (PFAS) through the urban water cycle: Toward achieving an integrated analytical workflow across aqueous, solid, and gaseous matrices in water and wastewater treatment. https://app.cochat.ai/papers/10.1016/j.scitotenv.2021.145257
The paper
Winchell, L. J., Wells, M. J. M., Ross, J. J., Fonoll, X., Norton, J. W., Kuplicki, S., Khan, M., & Bell, K. Y. (2021). Analyses of per- and polyfluoroalkyl substances (PFAS) through the urban water cycle: Toward achieving an integrated analytical workflow across aqueous, solid, and gaseous matrices in water and wastewater treatment. Science of The Total Environment. https://doi.org/10.1016/j.scitotenv.2021.145257

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.