Negative pressure cavitation based ultrasound-assisted extraction of main flavonoids from Flos Sophorae Immaturus and evaluation of its extraction kinetics
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this study, an efficient process of negative pressure cavitation based ultrasound-assisted extraction (NPC-UAE) was invented, and applied for the extraction of main flavonoids from Flos Sophorae Immaturus (FSI) for the first time. After the optimization of single factor and Box-Behnken design (BBD) experiments, the optimum technological conditions of NPC-UAE were determined as follows: ethanol concentration 72%, time 16 min, liquid to solid ratio 25:1 mL/g, ultrasonic intensity 0.347 W/cm2, negative pressure −0.07 MPa and temperature 60 °C. The extraction yields of rutin, nicotiflorin, narcissin, quercetin, kaempferol and isorhamnetin were 125.17, 15.02, 25.61, 51.89, 4.32 and 6.30 mg/g, respectively. The advantages of NPC-UAE were demonstrated by mass transfer kinetics. Under the optimal parameters, the extraction yields of NPC-UAE for six compounds were 1.27–1.62 and 1.17–1.40 folds to those of negative pressure cavitation extraction (NPCE) and ultrasound-assisted extraction (UAE), respectively. In terms of DPPH radical scavenging activity, the effect of NPC-UAE extracts was superior to other methods (UAE, NPCE). The results showed that NPC-UAE could not only extract flavonoids from FSI efficiently, but also have great advantages in extracting active components from sample matrix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemat, F., Rombaut, N., Sicaire, A.-G., Meullemiestre, A., Fabiano-Tixier, A.-S., & Abert-Vian, M. (2017) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2016.06.035 · Cited by 3,278
Ultrasound: A clean, green extraction technology
Tiwari, B. K. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.013 · Cited by 1,042
Chirinos, R., Rogez, H., Campos, D., Pedreschi, R., & Larondelle, Y. (2007) · Separation and Purification Technology · doi:10.1016/j.seppur.2006.12.005 · Cited by 320
Cui, Q., Peng, X., Yao, X.-H., Wei, Z.-F., Luo, M., Wang, W., Zhao, C.-J., Fu, Y.-J., & Zu, Y.-G. (2015) · Separation and Purification Technology · doi:10.1016/j.seppur.2015.06.026 · Cited by 206
Self-citationYang, R.-F., Geng, L.-L., Lu, H.-Q., & Fan, X.-D. (2017) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2016.06.037 · Cited by 83
Cited by
Selectivity of Current Extraction Techniques for Flavonoids from Plant Materials
Tzanova, M., Atanasov, V., Yaneva, Z., Ivanova, D., & Dinev, T. (2020) · Processes · doi:10.3390/pr8101222 · Cited by 187
Conventional and modern techniques for bioactive compounds recovery from plants: Review
Mungwari, C. P., King'ondu, C. K., Sigauke, P., & Obadele, B. A. (2025) · Scientific African · doi:10.1016/j.sciaf.2024.e02509 · Cited by 91
Modern Techniques for Flavonoid Extraction—To Optimize or Not to Optimize?
Jurinjak Tušek, A., Šamec, D., & Šalić, A. (2022) · Applied Sciences · doi:10.3390/app122211865 · Cited by 49
Ouyang, L., Liang, W., Bian, C., Shan, Y., & Wang, S. (2025) · Foods · doi:10.3390/foods14193325 · Cited by 7
“This phenomenon can be attributed to the cavitation effect of ultrasonic energy, which breaks down cell walls and facilitates the release of flavonoids [45].”
Metadata
- Authors
- Wang, G., Cui, Q., Yin, L.-J., Li, Y., Gao, M.-Z., Meng, Y., Li, J., Zhang, S.-D., & Wang, W.
- Venue
- Separation and Purification Technology
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 244
- Pages
- 115805
- ISSN
- 1383-5866 (ISSN-L)
- OpenAlex
- W2961702004
- Cited by
- 43
- References
- 5
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.