Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel utah slant electrode array (usea): Implications for long term functionality
Open accessAbstract
The encapsulation and packaging reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA)/integrated neural interface-recording version 5 (INI-R5) has been evaluated by monitoring the extended long term in-vitro functional stability and recording longevity. The INI encapsulated with 6-μm Parylene-C was immersed in phosphate buffer saline (PBS) at room temperature for a period of over 12 months. The USEA/INI-R5, while being soaked was powered and configured wirelessly through 2.765 MHz inductive link and the transmitted frequency shift keying (FSK) modulated radio-frequency (RF) (900 MHz Industrial, scientific, medical-ISM band) signal was also recorded wirelessly as a function of soak time. In order to test the long term recording ability, in-vitro wireless recording was performed in agarose for few channels. The full functionality and the ability of the electrodes to record artificial neural signals even after 12 months of PBS soak provides a measure of encapsulation reliability, the functional and recording stability in fully integrated wireless neural interface and potential usefulness for future chronic implants.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
USEA problems could be partly solved by making the device wireless.
“These problems could be partly solved by making the device wireless (Sharma et al., 2012).”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Sharma et al., 2012
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 720 · see citing works
Biomedical applications of diamond‐like carbon coatings: A review
Roy, R. K., & Lee, K. (2007) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30768 · Cited by 550 · see citing works
Encapsulation of an Integrated Neural Interface Device With Parylene C
Jui-Mei, H., Rieth, L. W., Normann, R. A., Tathireddy, P., & Solzbacher, F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002155 · Cited by 241 · see citing works
Self-citationWireless Neural Recording With Single Low-Power Integrated Circuit
Harrison, R. R., Kier, R. J., Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., Greger, B. E., Solzbacher, F., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023298 · Cited by 209 · see citing works
Self-citationLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · see citing works
Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating
Cogan, S. F., Edell, D. J., Guzelian, A. A., Liu, Y. P., & Edell, R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10152 · Cited by 170 · see citing works
Technology Insight: future neuroprosthetic therapies for disorders of the nervous system
Normann, R. A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0556 · Cited by 167 · see citing works
Self-citationHermesC: Low-Power Wireless Neural Recording System for Freely Moving Primates
Chestek, C. A., Gilja, V., Nuyujukian, P., Kier, R. J., Solzbacher, F., Ryu, S. I., Harrison, R. R., & Shenoy, K. V. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023293 · Cited by 130 · see citing works
Self-citationHsu, J.-M., Tathireddy, P., Rieth, L. W., Normann, A. R., & Solzbacher, F. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.04.050 · Cited by 104 · see citing works
Self-citationConverting thoughts into action
Scott, S. H. (2006) · Nature · doi:10.1038/442141a · Cited by 65 · see citing works
Tanielian, M. H., Kim, N. P., Wong, C. P., et al. (2000) · IEEE Transactions on Advanced Packaging · doi:10.1109/6040.883764 · Cited by 25 · see citing works
A wireless neural interface for chronic recording,
Harrison, R. R., Kier, R. J., Kim, S., Rieth, L., Warren, D. J., Ledbetter, N. M., Clark, G. A., Solzbacher, F., Chestek, C. A., Gilja, V., et al. (2008) · 2008 IEEE Biomedical Circuits and Systems Conference · doi:10.1109/biocas.2008.4696890 · Cited by 19 · see citing works
Self-citationSharma, A., Rieth, L. W., Tathireddy, P., Harrison, R. R., & Solzbacher, F. (2010) · Applied Physics Letters · doi:10.1063/1.3318251 · Cited by 13 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- [16]Warren DJ Ledbetter NM Kier RJ Sharma A Rieth LW Normann RA Solzbacher F Harrison RR Clark GA Wireless Recordings from Nerve and Brain Obtained with Fully Integrated 100-channel Utah (Slanted) Electrode Arrays Neural Interfaces Conference 2010
Cited by
Sorted by citations
Borton, D., Micera, S., Millán, J. D. R., & Courtine, G. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005968 · Cited by 171 · see citing works
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics
Rijnbeek, E. H., Eleveld, N., & Olthuis, W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00350 · Cited by 91 · see citing works
“These problems could be partly solved by making the device wireless (Sharma et al., 2012).”
BackgroundLong-term recording reliability of liquid crystal polymer <i>µ</i> ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63 · see citing works
Byun, D., Cho, S. J., & Kim, S. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125010 · Cited by 39 · see citing works
- Authors
- Sharma, A., Rieth, L., Tathireddy, P., Harrison, R., Oppermann, H., Klein, M., Töpper, M., Jung, E., Normann, R., Clark, G., & Solzbacher, F.
- Affiliations
- University of Utah (US)
- Fraunhofer Institute for Reliability and Microintegration (DE)
- Corresponding author
- Sharma, A.
- Venue
- Sensors and Actuators A Physical
- Publisher
- Elsevier BV
- Published
- 2012-12
- Volume
- 188
- Pages
- 167-172
- ISSN
- 0924-4247 (ISSN-L)
- PMC
- PMC3533439
- OpenAlex
- W2065610457
- Cited by
- 35
- References
- 14
- Citations by year
- 2025: 2 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 4 · 2018: 3 · 2017: 4 · 2016: 3 · 2015: 3 · 2014: 4 · 2013: 3
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- Locations
- Sensors and Actuators A Physical (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Funders
- Johns Hopkins University
- Technische Universität Kaiserslautern
- National Institutes of Health (5r01ns064318-02)
- National Institute of Neurological Disorders and Stroke (R01-NS064318)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- neural interfaces, wireless neural recording, parylene-C encapsulation, packaging reliability, chronic implantation, inductive power transfer, frequency shift keying, 900 MHz ISM band
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review