CoChat

Fabrication of a flexible penetrating microelectrode array for use on curved surfaces of neural tissues

Open access
Byun, Donghak, Cho, Sung Joon, Kim, Sohee · 2013 · Journal of Micromechanics and Microengineering

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

Conventionally, invasive neural microelectrodes for recording neuronal signals or stimulating the nervous system have been fabricated based on silicon substrate mainly due to well-established manufacturing processes. However, these silicon-based microelectrode devices have an issue of mechanical stability caused by the absence of flexibility when implanted onto curved surfaces of tissues. In this paper, a flexible and penetrating microelectrode array, a hybrid structure composed of silicon and elastomer, was devised and fabricated by bulk micromachining technologies. The structure uses individual silicon needles as independent electrodes in a square array and polydimethysiloxane (PDMS) as a base to support the needles. The dimensions of the electrode array and the needles are adjustable, depending on the number of needles, the pitch between the needles and the targeted penetration depth of the neural tissue. For mechanical characterization, the adhesion between PDMS and silicon was evaluated and the flexibility and integrity of the fabricated structure were investigated through flexural test and insertion test. Also, the electrochemical impedance spectroscopy of the electrodes was measured. The results suggest that the proposed microelectrode array is promising for use in neuronal recording and stimulation over curved surfaces such as cortical surface and peripheral nerves with larger curvatures.

Overview

Integrity signals

Registry

Crossref · 10.1088/0960-1317/23/12/125010

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 38 references

Research works printed but not linked: 6

  1. Pohlmeyer E A, 2007, Proc. 3rd Int. IEEE EMBS Conf. on Neural Engineering, 418
  2. Kim S-P, 2009, Proc. ASCC, 988
  3. Dowden B R, 2011, J. Neural Eng., 9
  4. Yao Y, 2004, Proc. IEEE, 26, 1994
  5. 10.1109/tbme.2003.820321 · DOI · Paper page
  6. Choi J, 2011, J. Micromech. Microeng., 21

Cited by

See all 40

Metadata

Authors
Byun, D., Cho, S. J., & Kim, S.
Affiliations
Gwangju Institute of Science and Technology (KR)
Corresponding author
Kim, Sohee
Venue
Journal of Micromechanics and Microengineering
Published
2013-10-30
Volume
23
Issue
12
Pages
125010
ISSN
  • 0960-1317 (ISSN-L)
  • 1361-6439
OpenAlex
W2108956075
Cited by
39
References
38
Citations by year
2025: 4 · 2024: 6 · 2023: 2 · 2021: 3 · 2019: 3 · 2018: 3 · 2017: 6 · 2016: 3 · 2015: 6 · 2014: 3
FWCI
1.96
Type
journal article
Language
en
Open access
Licence
Locations
Journal of Micromechanics and Microengineering (publishedVersion)
Funders
  • National Research Foundation
  • National Research Foundation of Korea (2010-0020786)
  • Ministry of Education, Science and Technology (2011-0016796, 2010-0020786)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
flexible microelectrode arrays, neural recording, neurostimulation, polydimethylsiloxane, bulk micromachining, bending test, electrochemical impedance, cortical surface, peripheral nerves

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fabrication of a flexible penetrating microelectrode array for use on curved surfaces of neural tissues. https://app.cochat.ai/papers/10.1088/0960-1317/23/12/125010
The paper
Byun, D., Cho, S. J., & Kim, S. (2013). Fabrication of a flexible penetrating microelectrode array for use on curved surfaces of neural tissues. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/23/12/125010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.