Cited by 71Electrochemical sensors and biosensorsAdvanced biosensing and bioanalysis techniquesbioluminescence and chemiluminescence research

An exercise degree monitoring biosensor based on electrochemiluminescent detection of lactate in sweat

Cai, Xia, Yan, Jilin, Chu, Haihong, Wu, Meisheng, Tu, Yifeng·2010·Sensors and Actuators B: Chemical

Integrity signals

Registry

Crossref · 10.1016/j.snb.2009.10.002

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A luminol-based biosensor for lactate detection achieved a detection limit of 8.9 × 10−12 mol/L and an average recovery of 101.3% using athlete sweat samples during a training course.

    “A detection limit of 8.9 × 10−12 mol/L and an average recovery of 101.3% was obtained when utilizing athlete sweat samples during a training course.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Cai, X., Yan, J., Chu, H., Wu, M., & Tu, Y.
Affiliations
Soochow University (CN)
Corresponding author
Tu, Yifeng
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2010-01
Volume
143
Issue
2
Pages
655-659
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2078145384
Cited by
71
References
18
Citations by year
2026: 2 · 2025: 5 · 2024: 3 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 7 · 2019: 2 · 2018: 7 · 2017: 4 · 2016: 5 · 2015: 2 · 2014: 5 · 2013: 5 · 2012: 9
FWCI
3.44
Type
journal article
Language
en
Open access
closed
Locations
Sensors and Actuators B Chemical (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
Keywords
electrochemiluminescence biosensor, lactate detection, sweat, exercise intensity monitoring, luminol, lactate dehydrogenase, pyruvate oxidase, NAD+ coenzyme, hydrogen peroxide, athletes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review