The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer
Abstract
Abstract The development of versatile and low-cost biosensor system for rapid and simultaneous detection of multiple blood metabolites is highly demanded for home healthcare. We developed a flexible microneedle electrode array-based biosensor (MEAB) and a multi-channel portable electrochemical analyzer (MPEA) for the simultaneous detection of glucose, uric acid, and cholesterol. Microneedle electrode array (MEA) was fabricated on the flexible substrate using magnetorheological drawing lithography, followed by sputter coated with Au/Ti film. Then, through biofunctionalized with glucose oxidase, uricase and cholesterol oxidase, MEA was conditioned as a biosensor for simultaneous detection of glucose, uric acid and cholesterol. MEAB demonstrated excellent sensing performance with a wide linear range (glucose, 2–12 mM; uric acid, 0.1–1.2 mM; cholesterol, 1–12 mM), low detection limit (glucose, 260 μM; uric acid, 4 μM; cholesterol, 440 μM), and rapid response time (∼4 s). MPEA, a homemade ARM STM32 microcontroller-based electrochemical analyzer, was validated to be comparable to that of the commercial electrochemical workstation. MPEA integrated with flexible MEAB could accurately and simultaneously detect glucose, uric acid, and cholesterol levels in serum, and the results were consistent with the portable electrochemical device. The ease-of-use of the reported biosensor system will facilitate effective monitoring of blood metabolites at home.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Cited by
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64
Jiang, L., Wang, L., Zhan, D.-S., Jiang, W.-R., Fodjo, E. K., Hafez, M. E., Zhang, Y.-M., Zhao, H., Qian, R.-C., & Li, D.-W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112918 · Cited by 41
Self-citation
Metadata
- Authors
- Gao, J., Huang, W., Chen, Z., Yi, C., & Jiang, L.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 287
- Pages
- 102-110
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2914139830
- Cited by
- 215
- References
- 2
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer. https://app.cochat.ai/papers/10.1016/j.snb.2019.02.020
- The paper
- Gao, J., Huang, W., Chen, Z., Yi, C., & Jiang, L. (2019). Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2019.02.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.