Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer

Gao, Jie, Huang, Wenzheng, Chen, Zhipeng, Yi, Changqing, Jiang, Lelun·2019·Sensors and Actuators B: Chemical

Abstract

Abstract The development of versatile and low-cost biosensor system for rapid and simultaneous detection of multiple blood metabolites is highly demanded for home healthcare. We developed a flexible microneedle electrode array-based biosensor (MEAB) and a multi-channel portable electrochemical analyzer (MPEA) for the simultaneous detection of glucose, uric acid, and cholesterol. Microneedle electrode array (MEA) was fabricated on the flexible substrate using magnetorheological drawing lithography, followed by sputter coated with Au/Ti film. Then, through biofunctionalized with glucose oxidase, uricase and cholesterol oxidase, MEA was conditioned as a biosensor for simultaneous detection of glucose, uric acid and cholesterol. MEAB demonstrated excellent sensing performance with a wide linear range (glucose, 2–12 mM; uric acid, 0.1–1.2 mM; cholesterol, 1–12 mM), low detection limit (glucose, 260 μM; uric acid, 4 μM; cholesterol, 440 μM), and rapid response time (∼4 s). MPEA, a homemade ARM STM32 microcontroller-based electrochemical analyzer, was validated to be comparable to that of the commercial electrochemical workstation. MPEA integrated with flexible MEAB could accurately and simultaneously detect glucose, uric acid, and cholesterol levels in serum, and the results were consistent with the portable electrochemical device. The ease-of-use of the reported biosensor system will facilitate effective monitoring of blood metabolites at home.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2019.02.020

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 215

Metadata

Authors
Gao, J., Huang, W., Chen, Z., Yi, C., & Jiang, L.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2019-05
Volume
287
Pages
102-110
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2914139830
Cited by
215
References
2
FWCI
8.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer. https://app.cochat.ai/papers/10.1016/j.snb.2019.02.020
The paper
Gao, J., Huang, W., Chen, Z., Yi, C., & Jiang, L. (2019). Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2019.02.020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.