Cited by 133Advanced Fiber Optic SensorsGas Sensing Nanomaterials and SensorsAnalytical Chemistry and Sensors

Graphene oxide-deposited tilted fiber grating for ultrafast humidity sensing and human breath monitoring

Open access
Jiang, Biqiang, Bi, Zhixuan, Hao, Zhen, Yuan, Qingchen, Feng, Dingyi, Zhou, Kaiming, Zhang, Lin, Gan, Xuetao +1 more·2019·Sensors and Actuators B Chemical

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2019.05.024

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Graphene oxide deposited onto a tilted fiber grating can monitor relative humidity and respiration with an ultrafast response within ∼42 ms and a sensitivity of 18.5 pm/%RH and 0.027 dB/%RH in the range of 30∼80% RH.

    “Relative humidity (RH) and so respiration can also be monitored by depositing graphene oxide onto tilted fiber grating [274]. Thus, it offers an ultrafast response within ∼42 ms and a sensitivity of 18.5 pm/%RH and 0.027 dB/%RH in the range of 30∼80% RH by monitoring the wavelength and intensity of the specific cladding mode resonance.”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [274]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. W. Wang, T. Sun, J. Peng, J. Dai, M. Yang, Humidity sensor based on fiber Bragg grating coated with different pore-foaming agent doped polyimides, IEEE Photon. Technol. Lett., 29(2017) 1963- 1966.

Cited by

Sorted by citations

Authors
Jiang, B., Bi, Z., Hao, Z., Yuan, Q., Feng, D., Zhou, K., Zhang, L., Gan, X., & Zhao, J.
Affiliations
  • Northwestern Polytechnical University (CN)
  • Aston University (GB)
Corresponding author
  • Gan, Xuetao
  • Zhao, Jianlin
Venue
Sensors and Actuators B Chemical
Publisher
Elsevier BV
Published
2019-08
Volume
293
Pages
336-341
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2943913006
Cited by
133
References
41
Citations by year
2026: 7 · 2025: 15 · 2024: 22 · 2023: 17 · 2022: 30 · 2021: 16 · 2020: 22 · 2019: 4
FWCI
6.47
Type
journal article
Language
en
Open access
Locations
  • Sensors and Actuators B Chemical (publishedVersion)
  • Aston Publications Explorer (Aston University) (submittedVersion)
Funders
National Natural Science Foundation of China (61775182, 61505165, 61522507)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
graphene oxide, tilted fiber grating, relative humidity measurement, cladding mode resonance, evanescent coupling, ultrafast response, water vapor permeation, fiber optic sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review