The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Lateral-flow technology: From visual to instrumental
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luminescent quantum dots for multiplexed biological detection and imaging
Chan, W. C. W., Maxwell, D. J., Gao, X., Bailey, R. E., Han, M., & Nie, S. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00282-3 · Cited by 2,068
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,654
Self-citationPosthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Home blood glucose biosensors: a commercial perspective
Newman, J. D., & Turner, A. P. F. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.012 · Cited by 900
Self-citationNanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
(2009) · Humana Press eBooks · doi:10.1007/978-1-59745-240-3 · Cited by 582
Replacing antibodies with aptamers in lateral flow immunoassay
Chen, A., & Yang, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.04.041 · Cited by 551
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 424
Gold nanoparticles in biology and medicine: recent advances and prospects.
Dykman, L. A., & Khlebtsov, N. G. (2011) · PubMed Central · Cited by 395
Gold Nanoparticles in Biology and Medicine: Recent Advances and Prospects
Dykman, L. A., & Khlebtsov, N. G. (2011) · Acta Naturae · doi:10.32607/20758251-2011-3-2-34-55 · Cited by 394
Ngom, B., Guo, Y., Wang, X., & Bi, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3661-4 · Cited by 386
On the Cyto‐Toxicity Caused by Quantum Dots
Shiohara, A., Hoshino, A., Hanaki, K., Suzuki, K., & Yamamoto, K. (2004) · Microbiology and Immunology · doi:10.1111/j.1348-0421.2004.tb03478.x · Cited by 385
Liu, J., Mazumdar, D., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603106 · Cited by 346
Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G. (2009) · Analytical Chemistry · doi:10.1021/ac8024653 · Cited by 344
Immunochromatographic methods in food analysis
Dzantiev, B. B., Byzova, N. A., Urusov, A. E., & Zherdev, A. V. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.11.007 · Cited by 333
Enhanced lateral flow immunoassay using gold nanoparticles loaded with enzymes
Parolo, C., de la Escosura-Muñiz, A., & Merkoçi, A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.06.049 · Cited by 331
Universal mobile electrochemical detector designed for use in resource-limited applications
Nemiroski, A., Christodouleas, D. C., Hennek, J. W., Kumar, A. A., Maxwell, E. J., Fernández-Abedul, M. T., & Whitesides, G. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405679111 · Cited by 285
Multiplex Lateral Flow Immunoassay for Mycotoxin Determination
Song, S., Liu, N., Zhao, Z., Njumbe Ediage, E., Wu, S., Sun, C., De Saeger, S., & Wu, A. (2014) · Analytical Chemistry · doi:10.1021/ac500540z · Cited by 262
Liu, G., Lin, Y.-Y., Wang, J., Wu, H., Wai, C. M., & Lin, Y. (2007) · Analytical Chemistry · doi:10.1021/ac070691i · Cited by 232
He, Y., Zhang, S., Zhang, X., Baloda, M., Gurung, A. S., Xu, H., Zhang, X., & Liu, G. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.079 · Cited by 220
Nanomaterial-enhanced paper-based biosensors
Ge, X., Asiri, A. M., Du, D., Wen, W., Wang, S., & Lin, Y. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.03.008 · Cited by 208
Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays
You, D. J., Park, T. S., & Yoon, J.-Y. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.014 · Cited by 208
Paper-based electroanalytical devices for accessible diagnostic testing
Maxwell, E. J., Mazzeo, A. D., & Whitesides, G. M. (2013) · MRS Bulletin · doi:10.1557/mrs.2013.56 · Cited by 189
Morales-Narváez, E., Naghdi, T., Zor, E., & Merkoçi, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02383 · Cited by 186
Yang, Q., Gong, X., Song, T., Yang, J., Zhu, S., Li, Y., Cui, Y., Li, Y., Zhang, B., & Chang, J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.09.002 · Cited by 183
Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays
Posthuma-Trumpie, G. A., Wichers, J. H., Koets, M., Berendsen, L. B. J. M., & van Amerongen, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5340-5 · Cited by 176
Wang, J., Liu, G., Engelhard, M. H., & Lin, Y. (2006) · Analytical Chemistry · doi:10.1021/ac060809f · Cited by 174
Immunochromatographic Diagnostic Test Analysis Using Google Glass
Feng, S., Caire, R., Cortazar, B., Turan, M., Wong, A., & Ozcan, A. (2014) · ACS Nano · doi:10.1021/nn500614k · Cited by 172
Paper‐Based Electrochemical Biosensors: From Test Strips to Paper‐Based Microfluidics
Liu, B., Du, D., Hua, X., Yu, X., & Lin, Y. (2014) · Electroanalysis · doi:10.1002/elan.201400036 · Cited by 147
Visual detection of microRNA with lateral flow nucleic acid biosensor
Gao, X., Xu, H., Baloda, M., Gurung, A. S., Xu, L., Wang, T., Zhang, X., & Liu, G. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.055 · Cited by 146
Functionalized Gold Nanoparticles for Applications in Bionanotechnology
Glomm, W. R. (2005) · Journal of Dispersion Science and Technology · doi:10.1081/dis-200052457 · Cited by 145
Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement
Anfossi, L., Nardo, F. D., Giovannoli, C., Passini, C., & Baggiani, C. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7428-6 · Cited by 143
Fernández‐Sánchez, C., McNeil, C. J., Rawson, K., & Nilsson, O. (2004) · Analytical Chemistry · doi:10.1021/ac0494937 · Cited by 129
Lateral Flow Immunoassays – from Paper Strip to Smartphone Technology
Eltzov, E., Guttel, S., Kei, A. L. Y., Sinawang, P. D., Ionescu, R. E., & Marks, R. S. (2015) · Electroanalysis · doi:10.1002/elan.201500237 · Cited by 127
Lateral Flow Immunoassay Using Europium Chelate-Loaded Silica Nanoparticles as Labels
Xia, X., Xu, Y., Zhao, X., & Li, Q. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.114561 · Cited by 122
A Strip Liposome Immunoassay for Aflatoxin B1
Ho, J. A., & Wauchope, R. D. (2002) · Analytical Chemistry · doi:10.1021/ac010903q · Cited by 114
Liu, C., Yeung, C., Chen, P., Yeh, M., & Hou, S. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.05.089 · Cited by 113
Carter, D. J., & Cary, R. B. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm269 · Cited by 113
Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies
Chan, C. P.-Y., Mak, W. C., Cheung, K. Y., Sin, K. K., Yu, C., Rainer, T. H., & Renneberg, R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092641 · Cited by 110
Self-citationPetryayeva, E., & Algar, W. R. (2015) · RSC Advances · doi:10.1039/c4ra15036h · Cited by 107
A wireless potentiostat for mobile chemical sensing and biosensing
Steinberg, M. D., Kassal, P., Kereković, I., & Steinberg, I. M. (2015) · Talanta · doi:10.1016/j.talanta.2015.05.028 · Cited by 84
Silver Enhancement of Gold Nanoparticles for Biosensing: From Qualitative to Quantitative
Liu, R., Zhang, Y., Zhang, S., Qiu, W., & Gao, Y. (2013) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2013.807817 · Cited by 70
Zhu, M., Wang, Y., Deng, Y., Li, Y., Adeloju, S. B. O., Pan, D., Xue, F., Wu, Y., Zheng, L., & Chen, W. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.04.049 · Cited by 70
MicroRNA detection using lateral flow nucleic acid strips with gold nanoparticles
Hou, S., Hsiao, Y.-L., Lin, M.-S., Yen, C.-C., & Chang, C.-S. (2012) · Talanta · doi:10.1016/j.talanta.2012.05.067 · Cited by 58
Rastogi, S. K., Gibson, C. M., Branen, J. R., Aston, D. E., Branen, A. L., & Hrdlicka, P. J. (2012) · Chemical Communications · doi:10.1039/c2cc33430e · Cited by 53
Printed Electrochemical Instruments for Biosensors
Beni, V., Nilsson, D., Arvén, P., Norberg, P., Gustafsson, G., & Turner, A. P. F. (2015) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0011510jss · Cited by 48
Self-citationQuantitative lateral flow immunosensor using carbon nanotubes as label
Abera, A., & Choi, J. (2010) · Analytical Methods · doi:10.1039/c0ay00412j · Cited by 43
Parlak, O., & Turner, A. P. F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.023 · Cited by 42
Self-citationAdvances in 2D/3D Printing of Functional Nanomaterials and Their Applications
Choi, J.-Y., Das, S., Theodore, N. D., Kim, I., Honsberg, C. B., Choi, H. W., & Alford, T. L. (2015) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0011504jss · Cited by 36
van Amerongen, A., van Loon, D., Berendsen, L. B. J. M., & Wichers, J. H. (1994) · Clinica Chimica Acta · doi:10.1016/0009-8981(94)90229-1 · Cited by 33
Zou, Z., Wang, J., Wang, H., Li, Y., & Lin, Y. (2012) · Talanta · doi:10.1016/j.talanta.2012.02.046 · Cited by 30
High performance immunochromatographic assay combined with surface enhanced Raman spectroscopy
Cho, I., Das, M., Bhandari, P. N., & Irudayaraj, J. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.02.091 · Cited by 24
Cited by
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena-Torralba, A., Bergua, J. F., Calucho, E., Fuentes-Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 576
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
McConnell, E. M., Cozma, I., Mou, Q., Brennan, J. D., Lu, Y., & Li, Y. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00240f · Cited by 477
Metadata
- Authors
- Mak, W. C., Beni, V., & Turner, A. P. F.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2016-05
- Volume
- 79
- Pages
- 297-305
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2205456549
- Cited by
- 264
- References
- 53
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.